INSTALLATION INSTRUCTIONS
ELECTRICAL INSTALLATION
Ÿ
Always follow the installation instructions in the instruction manual or the
product's spec sheet. This form is attached to the manual, in addition to
being sent by email upon approval of the order, it is also available on our
website (www.praticabr.com), in case of questions, contact Prática
Technical Assistance:
+55 35 3449-1235
(All world)
or 214-584-6269
(Only for United States and Canada).
Ÿ
The installation of the Prática ovens must be done with the necessary care to avoid
problems, damage to the equipment, and guarantee its full use.
Ÿ
This equipment must be installed by an authorized technician.
Ÿ
The equipment MUST be grounded.
Ÿ
The oven must have a exclusive circuit breaker.
Ÿ
Do not immerse the power cable or connect water to the unit.
Ÿ
Keep the power cord away from heated surfaces.
Ÿ
If the power cable is damaged, it must be immediately replaced by
an authorized technician to avoid shock hazards.
Ÿ
Only qualified personnel should open the equipment panel.
Ÿ
There is an equipotential point on the rear panel of the oven.
20
NEMA
6-30
3x10AWG
32
6.2
7.2
60
Single
208
240
USA/
Canada
Power
(kW)
Circuit
Breaker
(A)
Cable
Socket
Region
Voltage
(V)
Phases
Freq.
(Hz)
16A
(4P+E)
16
16
6.6
6.6
50
50
380
380
China
Australia
16A
(3P+N+E)
Multi
Multi
Europe
230
Single
50
6.9
32
3x4mm²
32A
(2P+E)
380
Multi
50
6.6
16
5x2,5mm²
16A
(4P+E)
COPA EXPRESS SINGLE MAG
5x2,5mm²
5x2,5mm²
Europe
230
Single
50
3.4
16
3x4mm²
16A
(2P+T)
400
Multi
50
6.9
16
5x2,5mm²
16A
(3P+N+E)
Asia
220
Single
60
6.6
32
3x4mm²
32A
(2P+E)
16A
(3P+N+E)
16
6.6
50
380
Africa
Multi
5x2,5mm²
L2
L3
L1
N