www.praherplastics.com
28
29 Troubleshooting
All LEDs on the keyboard are flashing at the same time
o
Motor overload
The pressure is too great on lifting the valve disk because the maximum
water column of 3m was exceeded
The pump does not switch off on lifting the valve disk
The V6 valve is soiled or clogged by foreign matter
The drive rotates continually without approaching a position
o
Device was driven without matching valve
Please return for repair; damage has already occurred in this case
The drive continually triggers the backwash cycle
o
Slide switch S3 is in the wrong position
See chapter 15 Setting of the electric pressure switch
o
Rotary switch S4 is set to too low a pressure
See chapter 15 Setting of the electric pressure switch
o
The system contains pressure boosting components (e.g., Solar absorbers)
Set the pressure sensor so that the Aquastar does not trip at this
increased pressure
o
The pressure sensor was retrofitted on a device that has a blue pressure sensor
switch below the PCB
Use the translation list enclosed with the pressure switch set, and set S3
or S4 accordingly
The pump fails to switch on or off
o
Slide switch S1 is in the wrong position
See chapter 17 Switch point for backwash and filter clock
o
Relay burnt out
The maximum pump current of 8A was exceeded
o
The pump is not properly connected
The pump must always be looped via contacts 13-14
The disk is not lifting freely, or the drive is not running smoothly, or flow noises
can be heard
o
The pump does not switch off on lifting the valve disk
The pump must always be looped via contacts 13-14
o
The drop from the water surface to the valve is too great
Make sure that the total water column does not exceed 3m.
o
The V6 valve is soiled or clogged by foreign matter
Clean the valve and use a pre-filter
The clock only triggers 1x
o
The clock break time not correctly programmed
For details of programming the clock, see chapter 16 Programmieren der
Digitaluhr für den Aquastar Comfort
The clock is flashing or there is no display
o
The clock battery is almost flat or flat
Change the clock battery (see chapter 28 Uhrenbatterie)
Summary of Contents for Aquastar Comfort 1001
Page 1: ...Zertifiziert nach certified acc to EN ISO 9001 2008...
Page 4: ...www praherplastics com 4...
Page 18: ...www praherplastics com 18 16 8 Datum und Uhrzeit einstellen...
Page 21: ...21 www praherplastics com 19 Anschlussplan f r Pumpe...
Page 29: ...29 www praherplastics com Notizen Notes...
Page 32: ...www praherplastics com 4...
Page 46: ...www praherplastics com 18 16 8 Setting of date and time...
Page 49: ...21 www praherplastics com 19 Connection diagram for pump...
Page 57: ...29 www praherplastics com Notes...
Page 58: ...www praherplastics com 30 Notes...
Page 59: ...31 www praherplastics com Notes...
Page 60: ...Praher Plastics Austria GmbH BA DEEN 15 02 182 C 90377A...