background image

 

NOTES ON THIS DOCUMENT

 

Before installing and using the wallbox the instructions must be read and understood in full by the installer and each user. 
Please keep the instructions for the entire service life of the wallbox in order to be able to access them later. 
Also observe the operating instructions for your electric vehicle. 

 

SAFETY, INSTALLATION, AND USE

 

The wallbox is only suitable for use in private and semi-public areas (e.g. company car parks). 
The wallbox must not be installed in areas where there is an explosive atmosphere (EX area) or where flammable liquids or 
objects are stored. 
The wallbox is only suitable for stationary installation. A minimum distance of 50 cm from all neighbouring objects must be 
maintained. Installation in a closed box is not permitted. Likewise the wallbox must not be installed in areas at risk of flooding. 

The wallbox may only be installed and put into operation for the first time by a trained electrician. 

The electrical connection must be made in accordance with nationally applicable standards and other national and international 
regulations regarding accident prevention and personal protection as well as fire protection. 
The wallbox may only be connected to and operated on TT, TN-C, and TN-C-S networks. Operation on an IT network is not 
permitted. 
Work on the wallbox may only be carried out when it is de-energised. There is a risk of fatal electric shock due to the 
components inside the box! 
Modifications or conversions to the wallbox are not permitted and will result in the loss of any guarantee or warranty claims 
against the manufacturer. 
The box and all associated components may only be used for their intended purpose. The manufacturer accepts no liability for 
personal injury or damage to property resulting from improper use. 
Defective or damaged wallboxes must not be put into operation. In this case, contact your installer. 
Check the function of the RCD switch regularly in accordance with national regulations. 

Summary of Contents for ALPHA XT

Page 1: ...ALPHA XT NRG1012 MANUAL Status May 2021...

Page 2: ...MOUNTING 6 ELECTRICAL CONNECTION 7 CONNECTION TO THE MAINS 7 SETTING THE MAXIMUM CURRENT 8 INITIAL COMMISSIONING 9 OPERATION 10 LED DISPLAY 10 LEARNING OF RFID CARDS 10 ERASING RFID CARDS 10 UNLOCKIN...

Page 3: ...ut into operation for the first time by a trained electrician The electrical connection must be made in accordance with nationally applicable standards and other national and international regulations...

Page 4: ...cle must be parked at a suitable distance from the charging station to ensure that the charging cable can be plugged in without tension Avoid direct sunlight Do not open an outdoor charging station du...

Page 5: ...sembled Operatinginstructions Drillingtemplate Fixing material consisting of 1x mounting bracket left 1x mountingbracket right 8x self tapping screws for mounting brackets 2 RFID cards additional card...

Page 6: ...x IK08 Number of charging connections 2 Charging connection coupling Typ 2 Length of charging cable m 5 5 Mounting location Indoor protected outdoor area Mounting type Wall mounting pillar mounting op...

Page 7: ...ck the proper fit of the cover and the tight fit of the cable glands after installation WALL MOUNTING 1 The enclosed mounting plates left right must be mounted on the back of the wallbox using four se...

Page 8: ...ly cable into the box 2 Connect the supply cable as shown in figure 2 and then relieve the strain and seal it using the cable gland RCD SWITCH CONNECTING TERMINALS FEED POINTS FOR SUPPLY CHAIN up to 1...

Page 9: ...mum current that the wallbox draws via the supply line must be set using the enclosed jumper on the control board When setting the maximum current it must not be higher than the fuse or the cable cros...

Page 10: ...t all vehicles from the system 2 Switchon the fuse in your house power box 3 Switchon the RCD switch located in the box The microcontroller will now start automatically Within 2 seconds the box report...

Page 11: ...not known all RFID cards successfully deleted 3 seconds white RFID card has been tuned in The LED indicator lights also show the preset current consumption every time the box is restarted LEARNING OF...

Page 12: ...y Charging points to which no vehicle is connected are blocked by the wallbox after 30 seconds As long as the connected vehicle is waiting or charging the connected charging point remains unlocked Aft...

Page 13: ...omatically Within 2 seconds the box signals the preselected setting by white flashing of the LEDs 10 flashes signal a presetting of 10 amps INTERFACE RS 485 The RS 485 interface communicates with Modb...

Page 14: ...not permitted The wallbox must not be cleaned with a water jet or high pressure cleaner ENVIRONMENT Disposeof the packagingmaterial via the collection containers for paper andplastics provided for yo...

Page 15: ...s Afterrepairorcleaning the wallboxcan beconnectedtothe mains If the fault has been rectified the box is ready for operation The vehicle suddenly charges with a lower chargingcurrentor briefly interru...