14
TROUBLESHOOTING
ERROR PICTURE
MEASURES
No function of the wallbox. (LEDs extinguished)
•
Check the fuses in the house distribution.
•
Check the RCD switch in the house distribution.
•
Check the internal fuses.
•
Check the internal RCD switch
Wallbox no longer responds.
•
First disconnect all vehicles from the system. Then restart the
wallbox.
The wallbox signals a fault (red LED display).
•
Disconnect the connection to the vehicle.
•
Check the charging coupling and charging cable for possible
damage.
•
In case of damage, disconnect the wallbox from the mains and
repair it.
•
Check the contacts of the charging coupler for dirt. To do this,
disconnect the box from the mains.
•
After repair or cleaning, the wallbox can be connected to the mains.
If the fault has been rectified, the box is ready for operation.
The vehicle suddenly charges with a lower
charging current or briefly interrupts the charging
process.
•
The wallbox is equipped with thermal overload protection.
•
From around 40°C outside temperature, the system gradually
reduces the maximum charging current.
•
If the ambient temperature continues to rise, the wallbox may
switch off the charging process.
•
As the outside temperature decreases, the wallbox automatically
continues the charging process.
The charging process was interrupted.
•
Start the charging process again. To do so, disconnect the wallbox
from the vehicle for 10 seconds.
CONTACT ADDRESS
PRACHT Industry GmbH
Am Seerain 3, 35232 Dautphetal-Buchenau, Germany
Phone +49 6466 9140-900