DEcLARATIoN oF coNFoRmITy

As manufacturer

PR electronics A/S
Lerbakken 10
DK­8410 Rønde

hereby declares that the following product:

Type: 5715
Name: Programmable LED indicator

is in conformity with the following directives and standards:

The EMC Directive 2004/108/EC and later amendments

EN 61326­1

  For specification of the acceptable EMC performance level, refer to the 

electrical specifications for the module.

The Low Voltage Directive 2006/95/EC and later amendments

EN 61010­1

Rønde, 17 December 2009 

Kim Rasmussen 

 

Manufacturer’s signature

Summary of Contents for 5715

Page 1: ...5 7 1 5 S I G N A L S T H E B E S T P r o g r a m m a b l e L E D I n d i c a t o r N o 5 7 1 5 V 1 0 2 U K F r o m s e r i a l n u m b e r 1 2 1 4 9 6 0 0 1 B 1 3 1 0 7 7 0 0 1 D ...

Page 2: ... electronics A S offre une large gamme de produits pour le traite ment des signaux analogiques et numériques dans tous les domaines industriels La gamme de produits s étend des transmetteurs de température aux afficheurs des isolateurs aux interfaces SI jusqu aux modules universels Vous pouvez compter sur nos produits même dans les conditions d utilisation sévères p ex bruit électrique vibrations ...

Page 3: ...pplication 7 Technical characteristics 7 Mounting installation 7 Applications 8 Order 5715 9 Electrical specifications 9 Sensor error detection inside and outside range 13 Connections 14 Block diagram 15 Routing diagram 17 Scrolling help texts 18 Configuration operating the function keys 20 Programming via PC 21 Graphic depiction of the relay function setpoint 21 ...

Page 4: ... followed The specifications must not be exceeded and the module must only be applied as described in the following Prior to the commissioning of the module this manual must be examined carefully Only qualified personnel technicians should install this module If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired WARNING Unti...

Page 5: ...st high temperatures mechanical vibrations and shock as well as rain and heavy moisture If necessary heating in excess of the stated limits for ambient temperatures should be avoided by way of ventilation All modules fall under Installation Category II Pollution Degree 1 and Insulation Class II Mounting Only technicians who are familiar with the technical terms warnings and instructions in the man...

Page 6: ... and Adjustment During calibration and adjustment the measuring and connection of external voltages must be carried out according to the specifications of this manual The technician must use tools and instruments that are safe to use Normal operation Operators are only allowed to adjust and operate modules that are safely fixed in panels etc thus avoiding the danger of personal injury and damage T...

Page 7: ...D indicator is in conformity with the following directives and standards The EMC Directive 2004 108 EC and later amendments EN 61326 1 For specification of the acceptable EMC performance level refer to the electrical specifications for the module The Low Voltage Directive 2006 95 EC and later amendments EN 61010 1 Rønde 17 December 2009 Kim Rasmussen Manufacturer s signature ...

Page 8: ...6 5715V102 UK Front and back layout Picure 1 Front of PReview 5715 Picture 2 Back of PReview 5715 ...

Page 9: ...al point and relay ON OFF indication All standard operational parameters can be adjusted to any application by way of the front function keys When programming is carried out by way of a PC and the configuration program PReset additional configuration options are available such as customer defined linearisation and special input signals Help texts in eight languages can be selected via a menu item ...

Page 10: ...4 23 22 21 66 65 64 63 62 61 32 31 1 2 3 4 8 5715V102 UK Applications Input signals Current Potentio meter Output signals 4 change over relays Analogue 0 4 20 mA Supply 21 6 253 VAC or 19 2 300 VDC Voltage RTD Lin R Connection wires 2 twire transmitter TC ...

Page 11: ...0 kHz Communications interface USB Loop Link Response time 0 90 100 10 Temperature input 1 s Current voltage input 400 ms Calibration temperature 20 28 C Accuracy the greater of general and basic values General values Input type Absolute accucary Temperature coefficient All 0 1 of reading 0 01 of reading C Type Internal consumption Max consumption 5715B 3 0 W 3 3 W 5715D 3 5 W 3 8 W Type Version 5...

Page 12: ...00 Pt200 Pt250 Pt300 Pt400 Pt500 Pt1000 Ni50 Ni100 Ni120 Ni1000 Cu10 Cu20 Cu50 Cu100 EMC immunity influence 0 5 of reading Basic values Input type Basic accuracy Temperature coefficient mA 4 µA 0 4 µA C Volt 20 µV 2 µV C Pt100 0 2 C 0 01 C C Linear resistance 0 1 Ω 0 01 Ω C Potentiometer 0 1 Ω 0 01 Ω C TC type E J K L N T U 1 C 0 05 C C TC type R S W3 W5 LR 2 C 0 2 C C TC type B 160 400 C 4 5 C 0 ...

Page 13: ...range 0 20 mA Programmable measurement ranges 0 20 and 4 20 mA Input resistance Nom 20 Ω PTC 25 Ω Sensor error detection loop break 4 20 mA Yes Voltage input Measurement range 0 12 VDC Programmable measurement ranges 0 1 0 2 1 0 10 and 2 10 VDC Input resistance Nom 10 MΩ Type Min value Max value Standard B E J K L N R S T U W3 W5 LR 0 C 100 C 100 C 180 C 200 C 180 C 50 C 50 C 200 C 200 C 0 C 0 C 2...

Page 14: ... Up Downscale 23 mA 3 5 mA Output limitation on 4 20 and 20 4 mA signals 3 8 20 5 mA on 0 20 and 20 0 mA signals 0 20 5 mA Current limit 28 mA Relay outputs Relay function Setpoint Hysteresis 0 100 On and Off delay 0 3600 s Sensor error detection Make Break Hold Max voltage 250 VRMS Max current 2 A AC Max AC power 500 VA Max current at 24 VDC 1 A Marine approval Det Norske Veritas Ships Offshore S...

Page 15: ...f the valid range of the A D converter or the polynomial is exceeded Input Range Readout Limit VOLT 0 1 V 0 2 1 V IN LO 25 mV IN HI 1 2 V 0 10 V 2 10 V IN LO 25 mV IN HI 12 V CURR 0 20 mA 4 20 mA IN LO 1 05 mA IN HI 25 05 mA POTM IN LO 0 5 IN HI 100 5 TEMP TC RTD IN LO temperature range 2 C IN HI temperature range 2 C LIN R 0 800 ohm IN LO 0 ohm IN HI 1 kohm 0 10 kohm IN LO 0 ohm IN HI 15 kohm Sen...

Page 16: ...41 42 43 44 45 46 41 42 43 44 45 46 41 42 43 44 45 46 mA 11 12 R2 R1 21 22 23 24 25 26 R3 R4 41 42 43 44 45 46 61 62 63 64 65 66 14 5715V102 UK Connections RTD Lin R 2 wire RTD Lin R 3 wire RTD Lin R 4 wire Potentiometer Voltage TC 2 wire transmitter Current Current Relays Inputs Output Supply Relays ...

Page 17: ...R4 1 3 2 Tx mA 5715V102 UK 15 Block diagram I Output Common Relay 1 N O Relay 1 N C Common Relay 2 N O Relay 2 N C Common Relay 3 N O Relay 3 N C Common Relay 4 N O Relay 4 N C Supply Supply 21 6 253 VAC or 19 2 300 VDC Version D 0 2 mA Int CJC 2 wire supply 15 VDC Input mA Input gnd RTD Lin R wires Potm PC communication Gnd ...

Page 18: ...1 9999 1 2 CONN 1 2 2W 3W 4W 3 3 3 CU TY CONN CU 3 1 2 1 2 10 100 2W 3W 4W 3 3 3 1 2 3 3 3 3 3 3 3 3 ADV SET YES 3 C LIN 1 4 DEC P 16 5715V102 UK 1 0 Default state 1 1 Only if password protected 1 2 Only is FastSet is enabled 1 3 Setpoint adjustment and relay test disabled at pass word 5000 9999 1 4 Only for special configura tion via PC 1 5 Not valid for these input signals Potentiometer 0 20 mA ...

Page 19: ...S NO 1 2 3 N PAS 0000 9999 1 2 3 NO 1 5 1 6 1 6 1 7 1 7 DE DK ES FR IT SE UK CZ X 2 4 ADV SET LANG DISP CAL 1 8 7 LIGH 3 1 7 1 2 LANG DISP CAL 1 2 3 3 UK HLP T 1 2 3 YES CA LO 3 YES NO 1 2 2 0 VAL L 3 100 0 0 0 1 2 NO 3 YES CA HI 3 1 2 90 0 VAL H 3 100 0 0 0 1 2 NO YES USE C 3 1 2 YES NO YES NO 3 5715V102 UK 17 Routing diagram If no key is activated for 2 minutes the display returns to default sta...

Page 20: ...ADOUT LOW DI HI xxxx DISPLAY READOUT HIGH REL U PERC SET RELAY IN PERCENTAGE DISP SET RELAY IN DISPLAY UNITS TYPE CU SELECT CU SENSOR TYPE PT SELECT PT SENSOR TYPE NI SELECT NI SENSOR TYPE TC SELECT TC SENSOR TYPE CU TY 10 SELECT CU SENSOR TYPE 20 SELECT CU SENSOR TYPE 50 SELECT CU SENSOR TYPE 100 SELECT CU SENSOR TYPE PT TY 10 SELECT PT SENSOR TYPE 20 SELECT PT SENSOR TYPE 50 SELECT PT SENSOR TYP...

Page 21: ...mA 4 20 OUTPUT RANGE IN mA 20 0 OUTPUT RANGE IN mA 20 4 OUTPUT RANGE IN mA O LO xxxx DISPLAY VALUE FOR OUTPUT LOW O HI xxxx DISPLAY VALUE FOR OUTPUT HIGH O ERR 23 mA NAMUR NE43 UPSCALE AT ERROR 3 5 mA NAMUR NE43 DOWNSCALE AT ERROR 0mA DOWNSCALE AT ERROR NONE UNDEFINED OUTPUT AT ERROR RESP xxx x ANALOGUE OUTPUT RESPONSE TIME IN SECONDS E PAS NO ENABLE PASSWORD PROTECTION YES N PAS xxxx SELECT NEW P...

Page 22: ...es or parameters If no key is activated for 2 minutes the display will return to the default state 1 0 without saving the changed values or parameters Furhter explanations Fast setpoint adjustment and relay test These menus are interactive and allow you to adjust the setpoints while the display is measuring the input sig nal The diodes will then indicate when the relays change state thus easing th...

Page 23: ...signals current voltage resistance and potentiometer This input type can be defined with special input spans e g 5 12 mA and customer defined linearisation with or without offset The customer defined input type is saved in the 5715 in the input menu C LIN If the display is later configured by way of the front keys for e g temperature input the input type C LIN containing all the original parameter...

Page 24: ... Galvanic isolators for analogue and digital signals as well as HART signals A wide product range with both loop powered and universal isolators featuring linearisation inversion and scaling of output signals Isolation Interfaces for analogue and digital signals aswellasHART signalsbetweensensors I Pconverters frequency signals and control systems in Ex zone 0 1 2 and for some devices in zone 20 2...

Page 25: ...prelectronics fr sales prelectronics fr www prelectronics de sales prelectronics de www prelectronics es sales prelectronics es www prelectronics it sales prelectronics it www prelectronics se sales prelectronics se www prelectronics co uk sales prelectronics co uk www prelectronics com sales prelectronics com www prelectronics cn sales prelectronics cn ...