5715V102-UK 9
Electrical specifications
Specifications range:
-20°C to +60°C
common specifications:
Supply voltage, universal ............................ 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Consumption:
Isolation voltage, test / operation ............... 2.3 kVAC / 250 VAC
Signal / noise ratio ...................................... Min. 60 dB (0...100 kHz)
Communications interface .......................... USB Loop Link
Response time (0...90%, 100...10%):
Temperature input .................................... < 1 s
Current / voltage input ............................. < 400 ms
Calibration temperature............................... 20...28°C
Accuracy, the greater of general and basic values:
General values
Input type
Absolute
accucary
Temperature
coefficient
All
≤
±0.1% of reading
≤
±0.01% of reading / °C
Type
Internal consumption
Max. consumption
5715B
3.0 W
3.3 W
5715D
3.5 W
3.8 W
Type
Version
5715
4 relays . . . . . . . . . . . . . . . . . . . .: B
Analogue output and 4 relays . .: D
order: 5715