EEx- / I.S.-Zulassung:
5531B:
DEMKO 02ATEX132122 ..............................   

II 1 G

 

EEx ib IIC T6

Für Anwendung in Zone ..............................  1 oder 2
5531B1:
KEMA 05ATEX1044 X .................................  -5°C 

≤ 

T

≤ 

+60°C 

II 3 GD T 85˚C

 

-20°C 

≤ 

T

≤ 

+60°C 

II 3 G

 

EEx nL IIC T6

Für Anwendung in Zone ..............................  2 oder 22
5531B2:
KEMA 05ATEX1105 X .................................  -5°C 

≤ 

T

≤ 

+60°C 

II 2 GD T 85˚C

 

-20°C 

≤ 

T

≤ 

+60°C 

II 2 G

 

EEx ib IIC T6

Für Anwendung in Zone ..............................  1, 2, 21, oder 22
Ex- / I.S-Daten:
Ui ................................................................. : 45 VDC

Ii ................................................................... : 500 mA

Pi ................................................................. : 0,9 W

Ci ................................................................. : 0 

μ

F

Li .................................................................. : 0 mH

goST R Zulassung:
VNIIM & VNIIFTRI, Cert. no. ........................  Siehe www.prelectronics.de
Eingehaltene Richtlinien: 

Norm:

EMV 2004/108/EG .......................................  EN 61326-1
ATEX 94/9/EC ..............................................  EN 50014, EN 50020, EN 60079-15,
 

EN 61241-0 und draftIEC 61241-11

Richtlinien zur eigensicherer Anwendung:
Nur die mit dem Modul gelieferten Verschraubungen und Blindstopfen dürfen 

benötigt werden.

Für Installation in explosionsgefährdeten Staub-Luft Bereichen wobei Kategorie 

3D oder 2D Apparatur gefordert ist, müssen die LCD Messgeräte Typ 5531B1 

und Typ 5531B2 so mosntiert werden, dass wenig Risiko mechanishen Schäden 

besteht. Diese zwei Modultypen dürfen nur in Umgebungen benötigt werden, wo 

die UV-Beleuchtung die nichtmetallischen Bestandteile nicht beeinflüssen kann.

Die ersten beiden Ziffern der Seriennummer zeigen das Herstellungsjahr.

A: Keine Hintergrundbeleuchtung.

B: Halbe Hintergrundbeleuchtung.

C: Volle Hintergrundbeleuchtung.

Siehe elektrische Daten betr. Spannungsabfall.

FELDgEhÄUSE TYP 8501:
Das 8501 erfüllt den Industriestandard zum Schutz von Prozessanlagen in 
Nassbereichen bis IP65. Wenn das 8501 vormontiert mit Display geliefert wird, 
ist die Einheit zugelassen zur Installation im explosionsgefährdeten Bereich für 
Gas, als auch in explosiver Staub Atmosphäre. Die technischen Spezifikationen 
des Feldgehäuses sind in dem Datenblatt 8501 zu finden.

ELEkTRISChE DATEN:
Umgebungstemperatur:
-20°C bis +60°C
Allgemeine Daten:
Max. Spannungsabfall bei 20 mA:
Ohne Hintergrundbeleuchtung ....................  < 1,5 VDC
Halbe Hintergrundbeleuchtung ...................  < 6,5 VDC
Volle Hintergrundbeleuchtung .....................  < 10,5 VDC
Ansprechdauer (0...90%).............................  < 1 S
Signaldynamik, Eingang ..............................  15 Bit
Kalibrierungstemperatur ..............................  20...28°C
Temperaturkoeffizient ..................................  < ±0,01% d. Messspanne/°C
Linearitätsfehler ...........................................  < ±0,1% d. Messspanne
EMV-Immunitätseinfluss ..............................  < ±0,5%
Anzugsmoment d. Schraubklemmen ..........  0,5 Nm
Luftfeuchtigkeit ............................................  < 95% (nicht kond.)
Abmessungen (HxBxT) ................................  48 x 96 x 120 mm
Einbauöffnungsmaße (HxB) .........................  44,5 x 91,5 mm
Schutzart (Front) ..........................................  IP65
Gewicht .......................................................  150 g
Eingang:
Messbereich ................................................  3,6...23 mA
Display:
Displayanzeige ............................................  ±9999 (4 Ziffern)
Min. Displayanzeige (Spanne) .....................  0 counts
Kommaplazierung .......................................  Programmierbar
Ziffernhöhe ..................................................  16 mm
Aktualisierungszeit  .....................................  500 ms

d. Messspanne = der gewählten Messspanne

Summary of Contents for 5531

Page 1: ...op powered and universal isolators featuring linearisation inversion and scaling of output signals PC or front programmable modules with universal options for input output and supply This range offers a number of advanced features such as process calibration linearisation and auto diagnosis A wide selection of transmitters for DIN form B mounting and DIN rail modules with analogue and digital bus ...

Page 2: ...overensstemmelseserklæring 2 Anvendelse 3 Teknisk karakteristik 3 Programmering skalering 3 Indbygningskasse type 8501 4 Elektriske specifikationer 4 Særlige betingelser for egensikker installation 5 Bestillingsskema 6 Blokdiagram 6 Programmeringsskema 7 Rutediagram 7 ...

Page 3: ...ringsmode Instrumentet kan nu programmeres ved at definere 0 og 100 visning samt kommaplacering se rutediagram Runmode I runmode viser displayet målestrømmen skaleret så 4 mA ind gangsstrøm viser indstillet 0 visning og 20 mA indgangsstrøm viser indstillet 100 visning Baggrundsbelysning Med DP1 sw 2 og 3 vælges imellem A Ingen baggrundsbelysning B Halv baggrundsbelysning C Fuld baggrundsbelysning ...

Page 4: ... de ikke metalliske dele Produktionsår fremgår af de to første cifre i serienummeret Indbygningskasse Type 8501 Indbygningskassen type 8501 modsvarer industriens krav til effektiv beskyttelse af procesudstyr i vådrumsmiljøer op til IP65 8501 med indbygget PReview 5531 har samlet Ex godkendelse til montering i såvel eksplosiv gasatmos fære som i eksplosivt støvmiljø Indbygningskassens tekniske deta...

Page 5: ...stand 0 0 RUTEDIAGRAM BLOKDIAGRAM 2 1 4 3 CPU EEPROM A D 5531 DP 1 DP 1 1 3 2 Ex kreds løb Kun version B Fronttaster Baggrunds belysning Indgang 4 20 mA Indgang Bestillingsskema 5531 Type Version Indbygningskasse 8501 5531 Standard A Ingen ATEX Ex B Ingen 8501 EEx nL IIC 1 8501 EEx ib IIC 2 DP 1 Fronttaster SW ON SW OFF Taster er låst Taster er IKKE låst 1 1 DP 1 Baggrundsbelysning SW ON SW OFF In...

Page 6: ...contents EC Declaration of Conformity 10 Application 11 Technical characteristics 11 Programming scaling 11 Field enclosure type 8501 12 Electrical specifications 12 Special conditions for safe use 13 Order 14 Block diagram 14 Programming 15 Routing diagram 15 ...

Page 7: ...ale mode the indicator may be scaled see routing diagram Run mode In run mode the indicator will display the actual current according to the scaling Backlight Dipswitch 1 switch 2 and 3 on the rear panel is used to select backlight intensity see programming Please note that the input voltage drop is dependent on backlight intensity EC DECLARATION OF CONFORMITY As manufacturer PR electronics A S Le...

Page 8: ...ic parts Year of manufacture can be taken from the first two digits of the serial number Field enclosure type 8501 The field enclosure type 8501 complies with industrial standards for efficient protection of process equipment in wet areas up to IP65 When 8501 is delivered with a built in PReview 5531 the assembled unit is approved for installation in explosive gas atmospheres as well as in explosi...

Page 9: ...turns to stage 0 0 ROUTING DIAGRAM BLOCK DIAGRAM 2 1 4 3 CPU EEPROM A D 5531 DP 1 DP 1 1 3 2 Ex circuit Only version B Front buttons Backlight input 4 20 mA input Order 5531 Type Version Field enclosure 8501 5531 Standard A None ATEX Ex B None 8501 EEx nL IIC 1 8501 EEx ib IIC 2 DP 1 Front keyboard SW ON SW OFF Keys locked Keys NOT locked 1 1 DP 1 Backlight SW ON SW OFF Off Half intensity Full int...

Page 10: ...ns 19 Caractéristiques techniques 19 Affichage 19 Configuration 19 Boîtier de protection type 8501 20 Spécifications électriques 20 Conditions spécifiques à l installation de sécurité intrinsèque 21 Référence de commande 22 Schéma de principe 22 Configuration 23 Diagramme de configuration 23 ...

Page 11: ...que la position de la virgule sont configurables à l aide des trois touches en face avant Voir Diagramme de configuration Un cavalier situé à l arrière de l indicateur permet de régler l intensité du rétro éclairage voir la configuration Il faut noter que la chute de tension est proportionnelle à l intensité du rétro éclairage La configuration depuis la face avant peut être verrouillée ou déverrou...

Page 12: ... grace aux deux premiers chiffres du numéro de série boitier de protection type 8501 Le boîtier de protection type 8501 répond aux standards industriels pour une protection efficace en ambience humide jusqu au degré IP65 Quand le 8501 est livré avec un indicateur PReview incorporé l unité assemblée est approuvée pour installation en zones d atmosphère explosible due à la présence de gaz ou de pous...

Page 13: ...pe Version Boîtier de protection type 8501 5531 Standard A Aucun ATEX Ex B Aucun 8501 EEx nL IIC 1 8501 EEx ib IIC 2 DP 1 Commande face avant SW ON SW OFF Commandes verrouillées Commandes NON verrouillées 1 1 DP 1 Rétro éclairage SW ON SW OFF 0 d intensité 50 d intensité 100 d intensité 2 3 2 2 3 ...

Page 14: ...chnis EG Konformitätserklärung 26 Anwendung 27 Technische Merkmale 27 Programmierung Skalierung 27 Feldgehäuse Typ 8501 28 Elektrische Daten 28 Richtlinien zur eigensicherer Anwendung 29 Bestellangaben 30 Blockdiagramm 30 Programmierung 31 Schleifendiagramm 31 ...

Page 15: ...zugänglich ist wird in die Stellung ON für die Aktivierung der fronttasten geschaltet wonach das Gerät in den Skalierungsmodus versetzt werden kann Skalierungsmodus Das Messgerät kann nun programmiert werden indem man die 0 und 100 Anzeige sowie die Kommaplazierung definiert siehe Schleifendiagramm Betriebsmodus In Runmode zeigt das Display den Messstrom so an dass 4 mA Eingangsstrom 0 und 20 mA E...

Page 16: ...nummer zeigen das Herstellungsjahr A Keine Hintergrundbeleuchtung B Halbe Hintergrundbeleuchtung C Volle Hintergrundbeleuchtung Siehe elektrische Daten betr Spannungsabfall Feldgehäuse typ 8501 Das 8501 erfüllt den Industriestandard zum Schutz von Prozessanlagen in Nassbereichen bis IP65 Wenn das 8501 vormontiert mit Display geliefert wird ist die Einheit zugelassen zur Installation im explosionsg...

Page 17: ...SCHLEIFENDIAGRAMM BLOCKDIAGRAMM 2 1 4 3 CPU EEPROM A D 5531 DP 1 DP 1 1 3 2 Ex Kreis lauf Nur Version B Fronttasten Hintergrund beleuchtung Eingang 4 20 mA Eingang Bestellangaben 5531 Typ Version Feldgehäuse Typ 8501 5531 Standard A Kein ATEX Ex B Kein 8501 EEx nL IIC 1 8501 EEx ib IIC 2 DP 1 Fronttasten Schalter EIN Schalter AUS Tasten sind gesperrt Tasten sind NICHT gesperrt 1 1 DP 1 Hintergrund...

Page 18: ...pour vous l assurance de la meilleure qualité PR electronics A S verfügt über ein breites Produktprogramm an analogen und digitalen Signalverarbeitungsmodule für die in dustrielle Automatisierung Dieses Programm umfasst Displays Temperaturtransmitter Ex und galvanische Signaltrenner und Universalgeräte Sie können unsere Geräte auch unter extremen Einsatzbedingungen wie elektrisches Rauschen Erschü...

Reviews: