background image

4 4222MCM101

Input type

Min. value

Max. value

Standard

mA

V

Pt10...Pt1000 

Ni50...Ni1000 

Lin. R 

Potentiometer

TC B 

TC E 

TC J 

TC K 

TC L 

TC N 

TC R 

TC S 

TC T 

TC U 

TC W3 

TC W5 

TC LR

0 mA

0 V

-200°C 

-200°C 

0 Ω 

10 Ω

0°C 

-100°C 

-100°C 

-180°C 

-200°C 

-180°C 

-50°C 

-50°C 

-200°C 

-200°C 

0°C 

0°C 

-200°C

20 mA

10 V

+850°C 

+250°C 

10000 Ω 

100 kΩ

+1820°C 

+1000°C 

+1200°C 

+1372°C 

+900°C 

+1300°C 

+1760°C 

+1760°C 

+400°C 

+600°C 

+2300°C 

+2300°C 

+800°C

-

-

IEC 60751 

DIN 43760 

-

IEC 60584-1 

IEC 60584-1 

IEC 60584-1 

IEC 60584-1 

DIN 43710 

IEC 60584-1 

IEC 60584-1 

IEC 60584-1 

IEC 60584-1 

DIN 43710 

ASTM E988-90 

ASTM E988-90 

GOST 3044-84

4222 Input Types and Ranges

0

°C

10

mils

20

in/s

30

kHz

40

MPa

50

GW

60

mV

70

gal/h

1

°F

11

yd

21

ips

31

Hz

41

kPa

51

MW

61

W

71

t/h

2

K

12

m

3

22

ft/s

32

p/min

42

hPa

52

kW

62

S

72

mol

3

%

13

L

23

in/min

33

p/h

43

bar

53

hp

63

µS

73

pH

4

m

14

s

24

ft/min

34

p/day

44

mbar

54

A

64

m

3

/min 74

[blank]

5

cm

15

min

25

in/h

35

t

45

kJ

55

kA

65

m

3

/h

6

mm

16

m/s

26

ft/h

36

kg

46

Wh

56

mA

66

l/s

7

µm

17

mm/s

27

m/s

2

37

g

47

MWh

57

µA

67

l/min

8

Ft

18

m/min

28

mm/s

2

38

N

48

kWh

58

V

68

l/h

9

in

19

m/h

29

rpm

39

Pa

49

W

59

kV

69

gal/min 

Table 1: Display units

Summary of Contents for 4511

Page 1: ...4511 MODBUS RTU Configuration Manual 4 2 2 2 Universal I f converter N o 4 2 2 2 M C M 1 0 1 1 4 4 5 F o r 4 5 1 1 d e v i c e s f r o m s e r n o 1 4 1 5 9 0 0 0 1 ...

Page 2: ...gment line termination 1 4222 Configuration Parameter List 2 General 2 Input 2 Display 2 Output 2 Table 1 Display units 4 4222 Input Types and Ranges 4 4222 Process Parameter List 5 4511 Modbus Configuration Parameter List 6 4511 Additional Parameter List 6 4511 Modbus Status Parameter List 6 4511 Modbus Front Programming Parameter Menu 7 ...

Page 3: ...odes Command Function code Read Holding Registers 03 Read Input Registers 04 Write Single Register 06 Diagnostics 08 Write Multiple Registers 16 The Function Code defines the command that the slave device is to execute such as read data accept data report status Some function codes have sub function codes The Data defines addresses in the device s memory map for read functions contains data values...

Page 4: ...R W UNSIGNED INTEGER Temperature units C 0 F 1 Input TEMP SENSOR TYPE 10 10 1 R W UNSIGNED INTEGER Temperature sensor type TC 0 Ni 1 Pt 2 Input PT TYPE 11 11 1 R W UNSIGNED INTEGER Pt value Pt10 Pt20 Pt50 Pt10 0 Pt20 1 Pt50 2 Pt100 3 Pt200 4 Pt250 5 Pt300 6 Pt400 7 Pt500 8 Pt1000 9 Input NI TYPE 12 12 1 R W UNSIGNED INTEGER Ni value Ni50 Ni100 Ni50 0 Ni100 1 Ni120 2 Ni1000 3 Input TC TYPE 13 13 1 ...

Page 5: ... types value is 1 10 Range equals the measurement range for the selected sensor type and must be higher than OUTPUT LOW Display DISPLAY CONTRAST 29 35 1 R W UNSIGNED INTEGER Contrast in the LCD display Range 0 9 Display DISPLAY BACKLIGHT 30 36 1 R W UNSIGNED INTEGER Backlight intensity in LCD Range 0 9 Display TAG TEXT 31 37 3 R W ASCII CHAR Tag of the device 6 characters Range ASCII values from 3...

Page 6: ...584 1 DIN 43710 IEC 60584 1 IEC 60584 1 IEC 60584 1 IEC 60584 1 DIN 43710 ASTM E988 90 ASTM E988 90 GOST 3044 84 4222 Input Types and Ranges 0 C 10 mils 20 in s 30 kHz 40 MPa 50 GW 60 mV 70 gal h 1 F 11 yd 21 ips 31 Hz 41 kPa 51 MW 61 W 71 t h 2 K 12 m3 22 ft s 32 p min 42 hPa 52 kW 62 S 72 mol 3 13 L 23 in min 33 p h 43 bar 53 hp 63 µS 73 pH 4 m 14 s 24 ft min 34 p day 44 mbar 54 A 64 m3 min 74 b...

Page 7: ...Range for non temperature input types DISPLAY LOW DISPLAY HIGH Range for temperature input types equals the measurement range for the selected sensor type PRIMARY VALUE 6 1007 2 R W FLOAT The measured value in 1 10 of C F for temperature Input types or the scaled display value for non temperature input types Range for non temperature input types DISPLAY LOW DISPLAY HIGH Range for temperature input...

Page 8: ...DDRESS 6 3005 1 R W INTEGER Configures the Modbus address of the 4511 Address 0 is broadcast address Range 1 247 RESPONSE DELAY 7 3006 1 R W INTEGER Configures minimum delay for Modbus response in ms Range 0 1000 4511 Modbus Status Parameter List Parameter Name No Register Address Register Size Read Write Type Description Values AUTOBAUD STATUS 1 4000 1 RO INTEGER Actual state of automatic baudrat...

Page 9: ...e 4511 The actual placement is defined for each particular device Scrolling HELP TEXTS 1 Set correct password 2 Enter advanced setup menu 3 Perform memory operations Enter display setup Perform process calibration Enter simulation setup Enter password setup Enter language setup Enter rail setup System 9000 Enter Modbus setup 4 Check automatic baudrate detection status Enable Modbus communication D...

Reviews: