background image

4/14 

 

 

 

INSTALL THE LIGHTING FIXTURE 

 

 

 

When the lighting fixture is used, put it on a flat surface or hang it. Make sure it is steady and secured. 
 

 

When the lighting fixture is used at a high place, as the figure above, move the support to the top of the lighting fixture, connect a lamp 
hook to the mounting hole reserved in the support by screws, and then hang the hook to mounting bar. Eventually, use the safety cord 
provided to pass through the support and hang it as a second safety fixing. 

 
 
 
 

CONTROL SYSTEM AND POWER CONNECTION 

 
 

DMX 512

2

DATA-

DATA+

3

1

GND

FUNCTION

PIN

三芯

DMX OUT

DMX IN

2

1

3

2

1

3

 

THREE-PIN 

Connection between the controller and a lighting fixture and between one lighting fixture and another must be made with a 2 
core-screened cable, with each core having at least a 0.5mm diameter. Please use the lighting fixture’s cannon 3- pin signal input and 
output cables as connection. The 3-pin signal connections are connected as shown in the figure above.   

Summary of Contents for PR-8920

Page 1: ...nual contains important information about the safe installation and use of this lighting fixture Please read and follow these instructions carefully and keep this manual in a safe place for future ref...

Page 2: ...g from them Every unit is completely tested and properly packed by the manufacturer Please make sure the packing and or the unit are in good condition before installation and use Should there be any d...

Page 3: ...relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cordcomeintocontactwi...

Page 4: ...Eventually use the safety cord provided to pass through the support and hang it as a second safety fixing CONTROL SYSTEMAND POWER CONNECTION DMX 512 2 DATA DATA 3 1 GND FUNCTION PIN DMX OUT DMX IN 2 1...

Page 5: ...a DMX terminator This prevents electrical noise from disturbing and corrupting the DMX control signals The DMX terminator is simply an XLR connector with a 120 ohm resistor connected across pins 2 an...

Page 6: ...nnels so set the No 1 lighting fixture s address 001 No 2 lighting fixture s address 007 No 3 lighting fixture s address 013 No 4 lighting fixture s address 019 and so on Launch the lighting fixture P...

Page 7: ...ing from dark to light 2 White 000 255 Linear Dimming from dark to light 3 Red 000 255 Linear Dimming from dark to light 4 Green 000 255 Linear Dimming from dark to light 5 Blue 000 255 Linear Dimming...

Page 8: ...lighting fixture at least once every 20 days Do not use any organic solvent e g alcohol to clean housing of the apparatus TROUBLESHOOTING PROBLEM ACTION The lighting fixture doesn t switch on Power c...

Page 9: ...inear color temperature correction from 3200K to 10000K DIMMER 0 100 linearly adjustable Light Source Luminous Flux 2100 lm STROBE Electronic Strobe 0 25F P S LIGHTANGLE FieldAngle 1 10 Maximum horizo...

Page 10: ...10 14 Light Output vertical direction SIZES...

Page 11: ...11 14 Electrical Diagram...

Page 12: ...ORDER CODES NAME PARTNO QUANTITY REMARK 3 PIN CONTROLCABLE 242810033 1 5m 200WPOWER SUPPLY 190010122 1 K18N UP200S58 LAMPBOARD 230060162 1 RGBW48 3W MAIN CONTROLBOARD 230060171 1 LED 4 CHANNELDRIVER B...

Page 13: ...13 14...

Page 14: ...14 14 PR LIGHTING LTD PR New Hi tech Science Park 1582 XingyeAvenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 FAX 86 20 3995 2330 P N 320020131 Version 20130513...

Reviews: