page no. 25 of 36
Vision Mini
User Instructions Doc Ref M608 issue 1.0 June 2021.
Modification for low-wall to high-wall
installation
If necessary, the air outlet can be changed from top to
bottom.
This operation must be performed while the appliance is
switched off and disconnected.
To make changes:
– if installed, remove aesthetic panels see chapter "Removal
of aesthetic panels and grilles"
p. 27
– Position the lower aesthetic cover kit (code GB0737II).
– fix with the screws provided
– remove the fixing screws of the right support bracket for
the flap
– Rotate the bracket 180°
– re-install the stirrup
– reassemble the aesthetic panel
– re-install the grid
see the chapter "Assembly of aesthetic panels and
grilles"
p. 27
A
Overhead installation
B
Low installation (factory settings)
1.
Aesthetic lower cover kit (Code GB0737II)
2.
Fixing screws (supplied with the optional kit GB0737II)
3.
Right support bracket for the flap
A
B
1
3
2
180°
Configuration
After adjusting the air outlet flap position, it is necessary to
set up the electronic control of the appliance.
With the display on:
–
Keep pressed the
button on the display for 10 seconds
The symbol appears
dn
(low wall) flashing.
–
press again the
key
The symbol appears on the display
(high wall).
–
Do not perform any other operations for 2 seconds
The new setting is memorised.
For the appliance to work properly, each time the
configuration of the air outlet flap is modified, the
electronic control must be set.
2.14 Setting cooling only or heating only mode
It is possible disable the heating or cooling function by
setting the unit to cold only or hot only mode.
–
Keep the
A
key pressed for 10 seconds on the display
Appear
HC
heating and cooling.
–
Press the
A
key for 1 second
Appear
CO
cooling only.