23
ER8
Insufficient
H2 Supply
The generator
is not receiving
sufficient
hydrogen fuel.
Generator
does not go
into ready
mode.
Inspect the
connection of
the regulator
assembly and
the ‘Hydrogen
Inlet’ port. Check
the regulator
assembly and
pressure on both
gauges.
ER16
Overcurrent
Too much current
is drawn from the
generator
Generator
shuts down.
Ensure that upon
re-starting the
generator, no load
is connected that
draws above the
nominal power
rating of the
generators.
ER32
Low Internal
Battery
The charge of the
internal service
battery is critically
low.
Generator
shuts down.
Prior to turning
the generator
back on, charge
its internal
battery (see 6.2).