   Installation notes

 

 :

1.

Negative Ground convention is used , that is the chassis of vehicle is 

connected to the negative terminal of the starting battery.

2.

Whenever possible, use the shortest connection to the unit and batteries.

The voltage drop of large current will affect the accuracy of isolator if cable  

size and length are not correctly selected.

Please refer to the following link...

http://www.zetatalk.com/energy/tengy10s.pdf

3.

Always double check the tightness of all connections by wiggling the 

connected terminals and etc. Connectors and fasteners are prone to vibration 

loosening in a moving vehicle.

Loosen connections cause sparks .

4.

Make sure the yellow wire (2) is isolated and insulated if not in use.

Use a toggle switch to connect this yellow wire to the positive terminal of the 

battery for manual connection of the Main and Aux terminals.

4.

      

   Installation for a Two Battery System

 

 

1.

Select the suitable Disconnect (LVD) and Connect voltages (LVR) according 

to your requirement. For a normal 2 battery system the LVD is about 12.4V 

and LVR is about 13.3V. However the selections depend on the relative 

capacity difference of the 2 batteries and load at the auxiliary battery. It is 

advisable to make the difference between LVD and LVR wider if rapid on off 

actions occur frequently.

2.

Please note that for the unit to function properly selections of LVR is always 

greater than LVD.

3.

Switch off the car of DC charging source, connect the Main terminal first then 

the Aux. terminal. Switch on the car or the DC charging source, if the main  

battery is full and the auxiliary is low the green LED will be on.

Summary of Contents for MB-3680

Page 1: ...Battery Isolators MB 3680 12V 100A and MB 3682 24V 100A User Manual REV 0 2011 02 7673 2112 2300 ...

Page 2: ...battery from the second battery in normal condition It allows charging of the second battery only when the main battery is at the selected voltage level set in LVR Connect This way it also diverts excess power from the alternator to run equipment that feeds from the second battery It does not allow the second battery to power the car electronics or feed into the starting of the car unless the manu...

Page 3: ... 3 Main Terminal for connection to the Positive battery terminal of main starting battery 4 Disconnect Voltage Selector LVD 5 Dual colour LED Indicator A No light Disconnect Green light Connect B Red light solid Over Voltage Protection for Main Terminal Red light slow flash Over Temperature Protection Red light fast flash Over Current Protection 6 Connect Voltage Selector LVR 7 Auxiliary Terminal ...

Page 4: ... in use Use a toggle switch to connect this yellow wire to the positive terminal of the battery for manual connection of the Main and Aux terminals 4 Installation for a Two Battery System 1 Select the suitable Disconnect LVD and Connect voltages LVR according to your requirement For a normal 2 battery system the LVD is about 12 4V and LVR is about 13 3V However the selections depend on the relativ...

Page 5: ...and LVR voltage are very much affected by the type of load and relative battery capacity Select a higher LVD for relatively smaller load for high initial draw load such as Motor choose a lower LVD 3 It is advisable to use a higher value of LVR to ensure a more completed charging operation 4 Check the battery s specifications for suitable LVR and LVD and in cycling or standby applications 5 If the ...

Page 6: ...4 Wide Operating Temperature Range 40 C to 60 C 5 Extruded Aluminum housing sealed with Polycarbonate end caps 7 Protections 1 Instant disconnection when main terminal drops to 8 5V 2 Over voltage protection at the main terminal 3 Over temperature to the isolator 90 C case temperature 4 Over current to the unit 5 Input reversed polarity protection to Main Terminal self reset ...

Page 7: ...olator Mode 15 Seconds Protection Low Voltage Protection No Delay 8 5VDC 0 5VDC 17VDC 1 0VDC Over Voltage Protection 18 5VDC 0 5VDC 34 5VDC 1 0VDC Over Temperature Protection Yes Protection Current Start Point 150A Continuous Output Current 100A Maximum Output Current 1 Minute 110A Operation Current Consumption LED ON 9mA Standby Current Consumption LED OFF 6mA Voltage Drop With 100A Main Batt To ...

Page 8: ...9 Dimension Diagram ...