4.
If the LED turns red at any time check on the specifications and make the
necessary remedial action. There is no connection and operation when LED
turns red. Once the fault has been cleared unit will return to normal operation.
5.
Installation for a One Battery System
1.
The selected LVD is usually lower than the two battery system since the unit
here is mainly used as a protection against over discharging the battery.
2.
However, the selection of LVD and LVR voltage are very much affected by the
type of load and relative battery capacity. Select a higher LVD for relatively
smaller load ; for high initial draw load such as Motor, choose a lower LVD.
3.
It is advisable to use a higher value of LVR to ensure a more completed
charging operation .
4.
Check the battery’s specifications for suitable LVR and LVD and in cycling or
standby applications.
5.
If the LED turns red at any time check on the section of LED INDICATIONS of
the specifications and make the necessary remedial action. There is no
connection and operation when LED turns red. Once the fault has been
cleared unit will return to normal operation.