Summary of Contents for Duecanali 1604

Page 1: ...7 Powersoft powersoft_Quattrocanali_servman_en_v2 8 Duecanali 804 Duecanali 1604 Duecanali 4804 Duecanali 804 DSP D Duecanali 1604 DSP D Duecanali 4804 DSP D Quattrocanali 1204 Quattrocanali 2404 Quattrocanali 4804 Quattrocanali 1204 DSP D Quattrocanali 2404 DSP D Quattrocanali 4804 DSP D ...

Page 2: ...Intentionally left blank ...

Page 3: ...5 2 5 CONTROL Board Layout 5 2 6 Rear Panel Board Layout 5 2 7 Front Panel Board Layout 5 3 Phoenix Connectors Connection Informations 6 Disassembling Procedure 6 1 Removing the Amplifier s Cover 6 2 Disassembling the Fan 6 3 Main Board Disassembling 6 4 Disassembling the DSP D CONTROL Board 6 5 Front Board Disassembling 6 6 Rear Board Disassembling 7 Troubleshooting 7 1 Testing the Amplifer with ...

Page 4: ...pect interior tighten back if possible 10 Temperature Sensor Remove and clean air filters and perform Reset Procedure 11 IP Address Refer to Chap 11 connect Amplifier to ArmoniaPlus to verify 12 Dante Failsafe Mode Refer to Chap 10 4 for Verifying Chap 10 5 for Recovery 13 Firmware Update Refer to Chap 13 carry out Firmware Update 14 Dante Firmware Update Refer to Chap 14 carry out Firmware Update...

Page 5: ... supply check LED LED If everything ok check DSP D Control Board 2 2 Reboot DSP D Control Board HW Check Internal LEDs Swap Golden Sample DSP D Control Board FW ArmonìaPlus Update Firmware 3 1 FAN No Fan Fan Check Voltage External Supply 3 2 Noisy Fan Mech Damage Loose Components Inside Visual Inspection Opened Chasis Close 3 3 Abnormal Behaviour DSP D Control Board HW Check Internal LEDs Swap Gol...

Page 6: ... Q ty Example Comments Dual stabilized power supply 30 Vdc 5 A 2 APLHA Electronica mod AL852D or equivalent Digital Oscilloscope 50 Mhz 1 TEKTRONIK TBS 1052B EDU or equivalent Signal generator 1 Rigol DG1022 Feeltech FY3200S Variac 1 Toroidal 3 KW Mono phase Dummy load 1500 W 8 Ohm 1 TE CONNECTIVITY CGS TE1500B10RJ Resistor Soldering Station 1 WELLER PU81 WSP80 or equivalent SMD rework soldering s...

Page 7: ... iron whose tip temperature cannot be controlled 4 2 Notes on REPLACING PARTS About the AMP Module The amplifier module of this unit is able to correspond to repairing in the component manufacturer Powersoft Company And it holds charge free warranty period for 16 months after production 4 3 Serial Number Labels The details of the Serial Number Labels is as follows On the DSP Board 4 4 MAC Address ...

Page 8: ...meter 13 Channel 1 level potentiometer 14 Power push button 15 Port reserved for servicing The left side and right side panels can be extracted by simply pulling on them releasing them from the magnet which holds them in place In order to clean the filters soak them in a mild soap and water solution rinse them out thoroughly and let them dry Please note that this is the only action that may be per...

Page 9: ...r cord inserted sectioning breaker closed the system can be either ON or in STANDBY mode depending on its state at latest power off In order to toggle the amplifier ON and STANDBY keep pressed the power button for 3 seconds Please consider that the operating condition can be modified by the REMOTE ON and REMOTE OFF configuration Restoring the Amplifier to its factory settings This procedure restor...

Page 10: ...l Type Action Description POWER Pushbutton keep pressed for 3 seconds Toggle system ready standby mode CALL Pushbutton press Highlight the amplifier in Armonia workspace SOFT RESET Pushbutton keep pressed for 3 seconds Reset network parameters to factory default HARD RESET Pushbutton keep pressed for 3 seconds Reboot the system CHECK Pushbutton keep pressed for 3 seconds Start the self checking pr...

Page 11: ...net Port J System Configuration Dip Switches K CH1 CH2 Output Configuration Dip Switches L CH3 CH4 Output Configuration Dip Switches 5 1 7 Duecanali Rear Panel Introduction G F K J I H E D B C A A AC Mains Connector B Air Vent C Output Connector D Line input Connector E Remote Levels Connector F Remote On Off G Alarm Connector H Dante Port DSP D version only I Ethernet Port J System Configuration ...

Page 12: ...s 5 2 Internal 5 2 1 Main Module Locations Layout EPROM NOTE When replacing the Main Board remove the Eprom by gently prying on its sides and place it in the new board The EPROM contains the following informations Model of the Amplifier Serial Number of the Amplifier MAC Address of the Amplifier Type of Rear Board Front Panel Board Quattrocanali 4CH Duecanali 2CH Quattrocanali 4CH Duecanali 2CH ...

Page 13: ...p CH2 Power Amp CH1 Power Amp Output Cable Bulk Capacitors Zobel Resistors Network PFC Converter EMI Filter Fuses PSU Control Section Rail Fuses F3000 F3001 10A 250VDc 5x20 mm Rail Fuses F1000 F1001 10A 250VDc 5x20 mm Varistors Fuses Layout Colour Description Fuse A Fuse B Varistors Old Versions New Versions ...

Page 14: ...14 QUATTROCANALI SERVICE MANUAL INDEX 5 2 3 Main Board MOSFETs Diodes Layout PFC 1 MOSFETs PFC 2 MOSFETs PFC 2 Diodes PFC 1 Diodes CH 1 MOSFETs CH 2 MOSFETs CH 3 MOSFETs CH 4 MOSFETs ...

Page 15: ...E Board Layout Colour Description Audio Control Section DANTE Section DANTE ETH Port DSP ETH Port Layout Colour Description Audio Control Section DSP Processor DSP ETH Port Layout 5 2 5 CONTROL Board Layout DSP D Board Old Version DSP D Board New Version ...

Page 16: ...itches Audio Input Connectors Remote Level Connectors Alarm Connectors Layout Colour Description CH Level Potentiometers LEDs Panel Layout 5 2 7 Front Board Layout Quattrocanali 4CH Duecanali 2CH Quattrocanali 4CH Duecanali 2CH QUATTROCANALI SERVICE MANUAL INDEX ...

Page 17: ...81 1803675 GPO ALARM Phoenix PC 5 8 STF1 7 62 1777891 Phoenix PC 5 8 STF1 7 62 1777891 REMOTE LEVEL INPUT Link Channel Pairs INPUT Analog Inputs not in use Phoenix MC 1 5 12 ST 3 81 1803675 Phoenix MC 1 5 4 ST 3 81 1803594 REMOTE ON REMOTE OFF Quattrocanali 4804 without DSP only Quattrocanali 2404 without DSP only Quattrocanali 1204 without DSP only Phoenix MC 1 5 12 ST 3 81 1803675 ...

Page 18: ...ning mechanism there is no need to remove the screws completely in order to open the amplifier s cover Untighten the screws by 3 complete turns 2 on each side Slide the side wings towards the back releasing them from the amplifier s chassis Gently pry the Front Panel slightly in order to completely expose the top cover s front side Gently remove the top cover ...

Page 19: ... fan s duct by gently unclipping the retainer indicated in the portrayed picture Lift and remove the fan s duct Unplug the fan s connector Note that the 2 screws highlighted in the following picture yellow sould not be present nor inserted It is now possible to remove the Fan ...

Page 20: ... Proceed by removing all the flat cables connecting the Main Board to the DSP D CNTRL and Front boards Also from the Rear Board to the DSP D CNTRL Board Older versions of the Quattrocanali feature the flat cables tucked in between the boards Please update this configuration as shown in the following pictures when reassembling the amplifier WRONG CORRECT ...

Page 21: ...3 1 5 6 4 7 8 2 3 1 5 6 4 7 8 Cable Number Cable Color Cable Number Cable Color 1 Gray 5 Yellow 2 Brown 6 Red 3 White 7 Black 4 Blue 8 Orange Focus your attention on the Output s Fastons Note that there are currently 2 versions of the main board s wiring these are easily recognizable by the color coding of the output terminations Refer to the following diagrams when reassembling the amplifier ...

Page 22: ...he new Main Board With a T10 Torx screwdriver remove the 8 screws highlighted yellow in the picture below It is now possible to extract the Main Board from the chassis please do so by gently pivoting it towards the front of the amplifier by pulling upwards and outwards on the heatsink ...

Page 23: ... as indicated Unscrew the 2 screws marked in red 5 retention pins are located on the points highlighted in light blue Gently push the DSP D Board towards the front of the amplifier releasing it from all retention pins Gently pry the back panel slightly so that it will become possible to lift the DSP D Board out of the chassis without damaging it ...

Page 24: ...move the 2 screws holding the front panel assembly to the rack ears one on each side By means of a T10 Torx screwdriver remove the 4 Torx screws highlighted in the portrayed picture It is now possible to remove the front board from the front panel Unplug the mains Faston connectors Unclip the safety retainer from the ground connector ...

Page 25: ... means of a T10 Torx screwdriver remove the 2 screws holding the rear panel assembly to the rack ears one on each side By means of a T10 Torx screwdriver remove the 5 Torx screws highlighted in the portrayed picture It is now possible to remove the rear board from the rear panel ...

Page 26: ...nal LEDs Checks Power Supply Section Normal Operating Conditions Colour Status LED Action GREEN ON RAIL None GREEN ON RAIL None OFF RAIL Check Standby LED Troubleshooting table Point 7 OFF RAIL Check Standby LED Troubleshooting table Points 7 13 16 17 Main Board PSU Section Main Board Colour Status LED Action GREEN ON PG None GREEN ON 15 None GREEN ON 15 None OFF BLINKING PG Check Standby LED Trou...

Page 27: ... CH 3 C RED OFF FAULT D GREEN ON ENA None CH 2 E GREEN ON ENA None F RED OFF FAULT Colour Status LED Action CH 1 G RED OFF FAULT H GREEN ON ENA None B A F E D C G H NOTE If any of the Channel ENA LED was Blinking GREEN Refer to Troubleshooting Standby LED Error Code Table Page 36 If any of the Channel FAULT LED was Lighted Up RED Refer to Troubleshooting Self Test Error Code Table Channel Fault Pa...

Page 28: ... A RED OFF K None B RED OFF K None ON Check Standby LED Troubleshooting table Points 7 CH1 CH2 Fuses Colour Status LED Action C RED OFF K None D RED OFF K None ON Check Standby LED Troubleshooting table Points 7 A B C D QUATTROCANALI SERVICE MANUAL ...

Page 29: ... Check Standby LED Troubleshooting table Point 7 and DANTE FW Colour Status LED Action I ORANGE BLINKING K None J GREEN BLINKING K None K ORANGE OFF K None L ORANGE ON K None ALL OFF Check Standby LED Troubleshooting table Point 7 Colour Status LED Action M ORANGE ON 14V None N GREEN ON 5V None O GREEN ON 3 3VD None P ORANGE ON 12V None Q ORANGE ON 12V None OFF 14V Check Standby LED Troubleshootin...

Page 30: ...E MANUAL 7 5 Checking the Fan Remove the FAN s connector as portrayed With a multimeter check the R361 Resistor R361 0 12 Ω Connect the fan to a DC power supply and check its consumption as portrayed on the picture 140 mA 10 12 Vdc ...

Page 31: ...oubleshooting LED Error table for further reference 8 2 Channel Faults Power supply fault AC Mains voltage out of range over under voltage PSU temperature out of range Channel Output Waveform non conformity Channel Temperature out of range Channel Output current measurement non conformity1 Fan Error ...

Page 32: ... to appear Check if the STANDBY LED is off Press and hold the Check button for 3 seconds The self check will start once the Check LED turns on Blinking Once the self check is complete the front LED panel will show the result of the test In this example the unit is displaying a fault in the AMP SECTION In this example the unit is displaying normal operating conditions Once the self check operations...

Page 33: ...ol or DSP D Board Contact Powersoft CHECK OFF Orange Auto test Completed Press the Check Pushbutton to return at Normal Working Condition OFF Auto test not Running Verify if the Mains voltage is correct Open the unit and Check all diagnostic LEDs conditions Contact Powersoft REMOTE OFF Green Preset has been Changed Armonia Disconnected Perform the Reset Procedure and Reconnect to Armonia Re Instal...

Page 34: ...he Rear switch status on OFF condition Check Internal LEDs Power AMP Section Check Internal LEDs DSP D Board Section 24dB OFF Green Channel Out Voltage Test Failed Reset Procedure and set the Rear switch status on OFF condition Check Internal LEDs Power AMP Section Check Internal LEDs DSP D Board Section SIGNAL OFF Green Channel Mute Perform Reset Procedure Check Internal LEDs Power AMP Section Up...

Page 35: ...s Power Supply Section Contact Powersoft MAINS Green OFF AC Mains Voltage Out of Range Overvoltage or Undervoltage Verify if the Mains voltage is correct Repeat Self Test Upgrade and Insert flat cables properly Measure the Rail Fuses Check Internal LEDs Power Supply Section ALARM OFF Red PSU Fault or Critical status Remove and Clean air filters and Perform Reset Procedure Check the Fan s consumpti...

Page 36: ...ilbus Voltage at Power ON Contact Service Centre Check Internal LEDs Power AMP Section Measure the Rail Fuses Replace Main Board Contact Powersoft STANDBY 8 Orange Disconnected or Open Circuit Fan Remove and clean air filters and perform Reset Procedure Check Internal LEDs Power AMP Section Check the Fan Consumption Replace Main Board Contact Powersoft STANDBY 9 Orange Short Circuited Fan Remove a...

Page 37: ...powers products available from hundreds of partners around the world For more information please visit the Audinate website at www audinate com 10 2 Dante Controller Downloading Dante Controller Dante Controller is available for download from Audinate s website To download a copy of Dante Controller 1 Go to the Audinate website www audinate com 2 Navigate to Products Dante Controller 3 Under Downl...

Page 38: ...collapse the sections Updates Available The Updates Available section of the Home tab lists devices that have been discovered on your Dante network which are eligible for a firmware update devices for which there is new firmware available in the Dante Updater database To update all eligible devices 1 Click Select All to select all the eligible devices 2 Click Update Selected Devices 3 When the upd...

Page 39: ...lsafe mode All Dante hardware modules use software loaded from Flash memory as part of their operation As with any storage device it is possible to corrupt the data on the Flash part potentially rendering it unusable if there are interruptions while writing to the Flash device By far the most common way for this to occur as with other Flash devices is by losing power to the Dante enabled device in...

Page 40: ...h at this point and click Failsafe Recovery again You will then see one of the two screens shown immediately below When you have restored one type of devices repeat the process for the other type 10 5 Using Failsafe Recovery Basic Steps To recover Dante devices in safe mode 1 Ensure the computer running Dante Firmware Update Manager and the device you wish to recover are on the same IP subnet foll...

Page 41: ...to the same network as Firmware Update Manager If you are sure that a device is in safe mode but Firmware Update Manager cannot find it contact your device manufacturer Select the devices that you wish to recover and click Start A pop up is displayed confirming that you wish to proceed 7 Click OK to start the recovery Firmware Update Manager will display Processing Safe Recovery and then Safe reco...

Page 42: ...re 1 Download the last version of Dante controller or at least 4 06 xx version and install it on your PC the download is available on https www audinate com products software dante controller 2 Execute Dante Controller on your PC 3 Click on Device Info and then click twice on the device to restore probably you will see it written in red ...

Page 43: ...200 121 6 Close Dante controller 7 On your PC enter Control Panel 8 Open Network and sharing center 9 Click on Change adapter setting 10 Right click on the network connection that you are using to connect the PC to the amplifiers ethernet connection and click on Properties 11 This window will be shown ...

Page 44: ...ies The following windows will be shown 13 Take note of your original configuration and then configure your computer s network interface with a static IP address in the same range as the IP address for the Dante device Use the same values for the first three octets and choose a different number from 1 to 255 for the last octet in this example Dante IP address is 169 254 200 121 then choose 169 254...

Page 45: ...stablished between the two devices YELLOW led ON ETH speed connection Amber on Operating as a Gigabit connection 1000 Mbps Green on Operating as a 100 Mbps connection Off Operating as a 10 Mbps connection Open ArmoniaPlus Application Click on the Shortcut Icon to open up Communication Manager Press Refresh wait for Connection to establish Click on to activate the network Click on to pause the netw...

Page 46: ...Unit to continue the test By hover the mouse cursor on top of the unit s icon it is possible to check the Model Serial Retel IP Address Firmware 7 9 10 8 11 12 Apply a 1KHz 1Vpp audio signal to CH1 Check for presence of the signal in all the other channel s VMeters 14 15 Function Generator Input 1 Connect a Function Generator tot Input 1 on the LINE connector as portrayed Signal 1KHz 1Vpp Sine App...

Page 47: ...mask will be automatically set 3 Copy the file upgrade4 v1 7 6 74 zip in local PC 4 Rename the file upgrade4 zip 5 On the front panel of your amplifier keep pressed four 4 push buttons all together CALL SOFT RESET HARD RESET CHECK 6 Power up the amp with the 4 buttons still pressed 7 Verify that all front leds turn ON Don t worry if some leds are ON OFF randomly for few seconds ...

Page 48: ...d port is blinking 10 Wait 20 sec and then launch the browser on your PC 11 Connect your PC to the amp writing 192 168 5 200 in the address bar of your browser The following screen will be shown Select upgrade firmware 12 The following screen will be shown 13 Click on Browse and select the file upgrade4 zip from you PC QUATTROCANALI SERVICE MANUAL ...

Page 49: ... front leds MAIN POWER ON and READY must be ON 16 When the procedure is finished you will see the Upgrading bar totally blue colored Don t worry if Upgrading is still displayed 17 Wait 2 minutes and then reboot the amplifier 18 Connect the amplifier to ArmoniaPlus and update the firmware to the last version available Remember to change again the IP address on your PC as it was before starting the ...

Page 50: ... By hovering the Mouse onto the unit the following information will be displayed EXAMPLE Model Quattrocanali 4804DSP D Serial 00506652 Device Address 169 254 9 71 Firmware 1 7 6 74 OLD VERSION Click on System List Check on the amplifier required to Update Firmware Click on the Update Selected Upon clicking the Update Selected the installation of Firmware begins After completed the updating Armonia...

Page 51: ...ante Firmware Or open View Tap to Launch Dante Updater Application Click on the Box to Select unit Click on the UPDATE SELECTED DEVICES Click on the Box to acknowledge Click on the UPDATE NOW to begin The Loading Bar shows the installing progress Within a minute the Updating of Dante Firmware will complete Upon Successful Update you may CLOSE the application check with Dante Controller ArmoniaPlus...

Page 52: ...ront Rear 4804 PF000461 SMD01149 R SM001101 R SM001098 R SM001100 R 1604 PF000462 SMD01096 R SM001101 R SM001098 R SM001100 R 0804 PF000460 SMD01096 R SM001101 R SM001098 R SM001100 R DUECANALI Yes DSP Yes Dante Product Code Main DSP DANTE Front Rear 4804 PF00H461 SMD01149 R SM001107 R SM001098 R SM001100 R 1604 PF00H462 SMD01096 R SM001107 R SM001098 R SM001100 R 0804 PF00H460 SMD01096 R SM001107...

Page 53: ...5 R 4CH LGT MAIN DISS FOR REPAIR QUATTROCANALI 2404 1204 MAIN BOARD SMD01096 R 2CH STD MAIN DISS FOR REPAIR DUECANALI 1604 804 MAIN BOARD SMD01149 R 2CH HGT MAIN DISS FOR REPAIR DUECANALI 4804 MAIN BOARD SM001097 R 4CH STD FRNT FOR REPAIR QUATTROCANALI FRONT BOARD SM001098 R 2CH STD FRNT FOR REPAIR DUECANALI FRONT BOARD 17 Replacement Parts ...

Page 54: ...CNTRL FOR REPAIR CONTROL BOARD SM001107 R 4CH STD DSP FOR REPAIR DSP BOARD VN000040 R BLOWER 120X120X32 _12V_1 12A FOR REPAIR ME001151 00 4CH Fan duct GU000096 02 AIR BOX GASKET F CABLE BLOCK IS000081 01 4CH MAKROFOL BASE ISOLATOR ME001100 02 4CH TOP COVER ME001099 02 4CH BASE ME001106 00 4CH SIDE BRACKET IC000117 24LC512 Series 512 Kb I2C 2 Wire 64K X 8 2 5 V Serial EPROM ...

Page 55: ... 1604 FRONT LABEL ET000590 00 2CH 1604 DSP DANTE FRONT LABEL ET000591 00 4CH 2404 FRONT LABEL ET000592 00 4CH 2404 DSP DANTE FRONT LABEL ET000593 00 4CH 4804 FRONT LABEL ET000594 00 4CH 4804 DSP DANTE_ FRONT LABEL ET000703 00 4CH 1204 FRONT LABEL ET000704 00 4CH 1204 DSP D FRONT LABEL ET000694 02 4CH LABEL FRONT REAR CASTING ET000696 02 2CH REAR FRONT CONTROLS ET000584 00 4CH FRONT LABEL ET000702 ...

Page 56: ...20A mains inlet socket 0722 1 PW25 CBK 0722 1 series CB000667 00 Cabl 4CH ground connection VI000393 SCW TCBTX M3X6_ T10_ SPEC_PWT GLSTL_ 4 8_ WHR_DIN127B VI000377 SCW TCTX M5X12 VI000276 01 SPC M3X5 MF RND BRASS_80PPM N VI000329 NUT M4_ ISO4161 A4 ME001117 MAGNET NEODIMIO CSN13 D13 H4 5mm VI000257 SCW_TSPTX_M3x8_ ISO14581_SL_ST_A2 QUATTROCANALI SERVICE MANUAL ...

Page 57: ... SLW 250V PCB _ RST_ LT23 0_ L _ VR000007 VARISTOR S20K385 CB000665 00 FLAT CABLE 20P L 45mm CB000666 00 4CH 34P INTERNAL CONNECTION CV000061 MAINS CABLE 3x1 5 16A SCHUKO SCHUKO TO IEC 320 C19 20A AC Mains cable CV000068 MAINS CABLE 3x1 5mmq 16A CN TO IEC 320 C19 20A AC Mains cable CV000078 MAINS CABLE SJT 16 3 USA JAPA TO IEC 320 C19 20A AC Mains cable ET000861 00 ANTI TAMPER LBL PWT GY SQUARE WA...

Page 58: ...abel after Repaired For every In Warranty repair you have to paste the Anti Tamper Label on the instructed position Upon receiving the Faulty Unit inspect the Label to see if there s any Tampering IF found any sign of damage to the Label Amplifier will consider Out Of Warranty ...

Page 59: ...SMD01095 R 100V ON None None Q103 gate With differential probe Grounded on D114 negative TEK00005 QUATTRO 4804 2404 1204 SMD01094 R SMD01095 R 100V ON Sine 1KHz 0 5Vrms 8 ohm x channel Q103 gate With differential probe Grounded on D114 negative TEK00006 QUATTRO 4804 2404 1204 SMD01094 R SMD01095 R 100V ON None None D102 anode Grounded on amplifier chassis TEK00007 QUATTRO 4804 2404 1204 SMD01094 R...

Page 60: ... R SMD01095 R 100 240V ON None None U1 pin 10 192KHz master clock CH3 4 Grounded on amplifier chassis TEK00014 QUATTRO 4804 2404 1204 SMD01094 R SMD01095 R 100 240V ON None None OUT CH1 Grounded on amplifier chassis Swicthing Frequency Output Residual TEK00015 QUATTRO 4804 2404 1204 SMD01094 R SMD01095 R 100 240V ON Sine 1KHz 0 5Vrms 8 ohm x channel OUT CH1 Grounded on amplifier chassis Audio Outp...

Page 61: ... subnet mask will be automatically set 6 Copy the file upgrade4 zip in local PC Note This upgrade4 zip File is the Standard File that normally used for the Powersoft Rescue Procedure In case the Service Team doesn t have it please request it from Powersoft HQ 7 On the front panel of your amplifier keep pressed four push buttons all together CALL SOFT RESET HARD RESET CHECK 8 Power up the amp with ...

Page 62: ...The Uploading Installing procedure will take approx 10 min During running procedure the LEDs condition will change randomly After some minute the Front Panel LEDs POWER ON and READY must be ON 18 When the procedure is finished you will see the Upgrading bar totally blue coloured 19 Wait 2 minutes and then reboot the amplifier 20 Reset the PC IP Address as Obtain an IP Address Automatically ...

Page 63: ...L 21 Launch ArmoniaPlus to Update the Firmware 23 Click UPDATE to begin 22 Select the Amp Click UPDATE 24 Uploading in progress 25 Installing in progress 26 Firmware Update completed 27 Note the IP Address of the Amplifier 169 254 xxx xxx ...

Page 64: ...xx and then Press Connect 31 The software will configure the amplifier as VOID then it will send automatically a Factory Default and Reboot 32 Launch ArmoniaPlus to check IP Address of the VOID Bias 33 Launch the browser on your PC 34 Connect your PC to the Amp writing 192 254 xxx xxx update in the address bar of your browser The following screen will be shown Select upgrade firmware ...

Page 65: ...After some minute the Front Panel LEDs POWER ON and READY must be ON 38 When the procedure is finished you will see the Upgrading bar totally blue coloured 39 Launch the browser on your PC 40 Connect your PC to the Amp writing 192 254 xxx xxx in the address bar of your browser The following screen will be shown Note Notice the Top Left Corner ICON had changed This shows you that you had successful...

Page 66: ...ear Must be Worn Observe precaution for handling Electrostatic Discharge sensitive devices Safety precautions We recommend to follow all precautions stated by the law while handling sensitive electrical components All of the servicing work must be carried in a EPA ESD compliant environment with the exception of the mere handling of the mechanical parts An ESD protected workstation consists in Stat...

Page 67: ...Intentionally left blank ...

Page 68: ...ble on www powersoft audio com Powersoft S p A Via Enrico Conti 5 50018 Scandicci FI Italy Tel 39 055 735 0230 Fax 39 055 735 6235 General inquiries info powersoft it Sales sales powersoft it Application technical support support powersoft it Service maintenance service powersoft it powersoft audio com ...