5. Service  

                                                                     

 

WARRANTY CONDITION:  
 
The standard warranty is TWO (2) years from the date of purchase. The standard PowerShield 

procedure is to replace the original unit with a factory refurbished unit. PowerShield will ship the 
replacement unit once the defective unit has been received by the service department, or cross 
ship upon the receipt of a valid credit card number. The customer pays for shipping the defective 
unit to PowerShield. PowerShield pays ground freight transportation costs to ship the 

replacement to the customer within Australian capital cities metro areas only. 
 
NOTE : For more information about our Warranty Policy, please visit our web site. 

www.powershield.com.au 

 
WARRANTY SEVICE PROCESS :  

 
1.

 

Review the problems discussed in the troubleshoot section of this manual to eliminate 
common problems. 

2.

 

Verify that no input/output circuit breaker are tripped. A tripped circuit breaker is the most 

common problem. 

3.

 

If the problem still persists, please call 1300-305-393 for technical support or fill in the form 
in PowerShield web page for on line technical support. 

Following details are needed for warranty claims. 

 

Model number 

 

Serial number 

 

The date of purchase 

4.

 

Be prepare to troubleshoot the problem over the phone with PowerShield technical support. 

5.

 

If technical support found that the product is defective, then the technical support will issue a 
Return Material Authorization Number ( RMA # )  

6.

 

If the unit is under warranty, repair is free. If not there is a repair charge. 

7.

 

Pack the unit in its original packaging. Pack properly to avoid damage during transit. Damage 
sustained in transit is not covered under warranty. 

8.

 

Mark the RMA # on the outside of the package. 

9.

 

Return the defective unit by insured, prepaid carrier to the address given to you by Technical 
support. 

 

 

 

Summary of Contents for PSCM1100

Page 1: ...nteractive Sinewave UPS Uninterruptible Power Supply System t l lbwer f Shield NetGuard UPS Monitoring Software IMPORTANT Download the latest NetGuard Monitoring Software www powershield eom au index...

Page 2: ...sags power surges under voltage over voltage line noise frequency variation switching transients and harmonic distortions The Commander will continuously protect your equipment by internally isolating...

Page 3: ...nd the associated warning should be observed CAUTION REFER TO OPERATOR S MANUAL Refer to your operator s manual for additional information such as important operating and maintenance SAFETY EARTHING T...

Page 4: ...up 6 2 1 Rear Panel View 6 2 2 Setup the UPS 6 3 Operations 9 3 1 Button Operation 9 3 2 LCD Panel 9 3 3 Audible Alarm 10 3 4 LCD Display Wordings Index 11 3 5 UPS Setting 11 3 6 Operating Mode Descri...

Page 5: ...the UPS system near water or in moist environments Do not install the UPS system where it would be exposed to direct sunlight or near heater Do not block ventilation holes in the UPS housing 1 3 Inst...

Page 6: ...nect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS capacitors Only persons are adequately familiar with...

Page 7: ...eaker 5 Emergency power off function connector EPO 6 USB communication port 7 RS 232 communication port 8 SNMP intelligent slot 2 2 Setup the UPS Before installing the UPS please read below to select...

Page 8: ...lug the UPS into a two pole three wire grounded receptacle only Avoid using extension cords Step 2 UPS output connection There two kinds of outputs programmable outlets white coloured outlets and gene...

Page 9: ...5 Turn on the UPS Press the ON Mute button on the front panel for two seconds to power on the UPS Note The battery charges fully during the first five hours of normal operation Do not expect full bat...

Page 10: ...this button at least 2 seconds to turn off the UPS Confirm selection key Press this button to confirm selection in UPS setting mode SELECT Button Switch LCD message Press this button to change the LCD...

Page 11: ...level by 0 25 26 50 51 75 and 76 100 Indicates overload UPS status Indicates that programmable management outlets are working Indicates that the UPS alarm is disabled Indicates the UPS powers the out...

Page 12: ...Battery AH EPO Emergency Power Off AC Active Close AO Active Open ESC Escape ON ON OK OK EP EPO TP Temperature CH Charger BF Battery Fault BR Battery Replace EE EEPROM error 3 5 UPS Setting Parameter...

Page 13: ...veform Sensitivity setting Interface Setting Set up input waveform sensitivity St1 Input voltage waveform detection is highly sensitive St2 Input voltage waveform detection is middle sensitive Default...

Page 14: ...PO logic it will activate EPO function with Pin 1 and Pin 2 in close status 00 Exit setting Interface Setting Exit the setting mode Steps for setting programmable outlet White Coloured Outlets Step 1...

Page 15: ...ge is within voltage regulated range UPS will power the output directly from the mains ECO is an abbreviation of Efficiency Corrective Optimizer mode In this mode when battery is fully charged the fan...

Page 16: ...nverter voltage Low 13 x Charger failure 45 x 3 8 Warning Indicator Warning Icon flashing Alarm Low Battery Rapid one beep every second Overload 2 short beeps every 2 seconds Battery is not connected...

Page 17: ...flashing on LCD display and alarm is sounding 2 short beeps every 2 seconds The external or internal battery is incorrectly connected Check if all batteries are connected well Fault code is shown as...

Page 18: ...ime is shorter than nominal value Batteries are not fully charged Charge the batteries for at least 5 hours and then check capacity If the problem still persists consult your dealer Batteries defect C...

Page 19: ...l to eliminate common problems 2 Verify that no input output circuit breaker are tripped A tripped circuit breaker is the most common problem 3 If the problem still persists please call 1300 305 393 f...

Page 20: ...b site www powershield com au support php 6 2 Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance w...

Page 21: ...hours recover to 90 capacity PROTECTION Full Protection Overload thermal short circuit discharge and overcharge protection Surge Protection 1968Joules 39000 Amps COMMUNICATION MANAGEMENT Interface USB...