27
OPTIONAL ACCESSORIES for Model 15S Planer
708816 . .........Knives (set of 3)
2230002 .........Bed and feed roller gauge
............. .........Battery for digital scale
............. .........Battery cover
TROUBLE-SHOOTING: Digital Scale
PROBLEM POSSIBLE
CAUSE
SOLUTION
Flashing digits.
1. Low voltage.
1. Replace battery.
Locked digits.
1. Haphazard memory.
1. Take battery out, wait thirty seconds,
then re-insert it.
No display.
1. Poor contact of battery.
1. Improve battery contact.
2. Low voltage.
2. Replace battery.
Displays only ‘0000’.
1. Short-circuit of zero setting spring
1. Remove frame and adjust spring.
and slider signal source.
Function buttons won’t
1. Distortion of springs from
1. Remove frame and adjust springs.
work.
over-pressing.
Summary of Contents for 15S