7.3.
Changing oil
Drain the oil while the engine is still warm to assure rapid and complete draining.
•
Make sure to turn the ignition switch “OFF” before draining the oil.
1.
Loosen the oil access cover screw and the remove cover.
2.
Remove the oil dipstick.
3.
Install the oil drain pipe (included with the generator).
4.
Drain the dirty oil into a container. Be sure to allow time for the oil to drain completely.
5.
Refill with the recommended oil, and check to be sure the oil level is at the upper line on the dipstick.
6.
Reinstall the oil access cover and tighten the screw securely.
Recommended oil is SAE 10W-30 or 15W-30 when ambient temperature is above 32° F (0° C).
SAE 0W-30 or 0W-40 is recommended if operating temperatures are below 32° F (0° C).
Synthetic oil is approved for use in POWERHOUSE
®
generators generally, and is recommended when operating the
generator in temperatures below 32° F. You can use synthetic oil the first time you fill the oil well of your generator, and
you can use it for subsequent oil changes.
Engine oil capacity: 33.8 fl oz (1.0 L)
•
Please dispose of used motor oil in a manner that is compatible with the environment and local
disposal regulations. Do not throw it in the trash or pour it on the ground.