![PowerGrip YG-3 Manual Download Page 6](http://html1.mh-extra.com/html/powergrip/yg-3/yg-3_manual_1589445006.webp)
Settings menu
To enter the menu press and hold Main button (2) until you will see the menu on screen. Please be aware
that changes of settings can result in unexpected power status of connected devices.
Root menu:
Exit
-Exit
Filtering
-Filtering settings
Display
-Display settings
Commutation -Power groups, trigger out and protection time settings
Wi-Fi
-Wi-Fi setup
Sequencer
-Power groups on/off timing settings
Control
-Auxiliary control settings
Information
-Device information
Save
-Press ‘Save’ to save your settings. If you do not save your settings after making changes, the
settings will be restored to the previous values after on/off or protection has been triggered.
Filtering:
Filter
-Trigger options for filter state. Go to Trigger options list for details.
Filt. Dumper
-Trigger options for filter Dumper state. Go to Trigger options list for details.
Does not operate if the Filter option is not activated.
DC filter
-Trigger options for DC filter. Go to Trigger options list for details
Auto Threshold
-Amount of DC voltage to trigger DC filter.
Ground indicator
-Turn off ground indicator. This may be required in TT (functional earthing) power
systems if the neutral to ground voltage is high.
Trigger option list:
<Power ON> -Activation at power on.
<Sens.btn1> -Activation with sensor 1(enumeration from left to right) *
<Sens.btn2> -Activation with sensor 2(enumeration from left to right) *
<Sens.btn3> -Activation with sensor 3(enumeration from left to right) *
<Sens.btn4> -Activation with sensor 4(enumeration from left to right) *
<Sens.btn5> -Activation with sensor 5(enumeration from left to right) *
<Trigger>
-Activation with trigger input.
<I Group1>
-Activation with current drain from Group1. Check Control menu for settings. Group1 must
be set to ‘always ON’ to let this function work. Go to Commutation Menu to set Group1 to
‘always ON’.
<Amb.Light> -Activation with illumination of YG-3. The Threshold can be set in the ‘Display’ section of
menu. ‘OFF Threshold’ controls the level of activation. In case the display is set to auto
option, when the display is turned off/on this function will trigger as well.
<OFF> or <----> -No trigger option assigned.
<Auto>
-Automatic activation. *Can be set for DC blocker only.
*Sensor button LED shows assigned state. If more functions are assigned, those are controlled together.