![PowerGrip YG-3 Manual Download Page 10](http://html1.mh-extra.com/html/powergrip/yg-3/yg-3_manual_1589445010.webp)
Control:
Group 1 current:
-Current drain from group 1. Group 1 must be on to let this function work. go to
commutation menu to set it.
On threshold
-The amount of current to turn on assigned function. < I Group1> must be
assigned to any function in commutation or sequencer menus.
0 - function is disabled.
Group 1 must be set always on to let this function work.
Off threshold
-Assigned function will be turned off below this value. < I Group1> must
be assigned to the function in commutation or sequencer menus.
0 - function is disabled.
This function value mast be lower than "On threshold".
How to set threshold:
1)Turn On device connected. Set on threshold a little less than current consumption value. If console turn on
will be unstable set it one step less.
2)Turn connected device into standby mode. Set off threshold a little more than current consumption value.
On threshold must higher than the off threshold.
RS232 address
-RS232 address for control system.
RS232 terminal
-terminal for RS232 test.
Ethernet terminal
-terminal for Ethernet test *
Ethernet ECO
-turn off Ethernet power if all groups are off*
*Available if the optional Ethernet module is installed. The Ethernet module is not included as standard kit.
Information:
Online time
-Online time. any power fault will cause timer reset.
Grounding
-Information about grounding
Model
-Device model
Firmware
-Firmware version
Save:
Select ‘Save’ to save the settings made in the menu. If you do not save your settings, they will reset to
previous values after on/off or a power fault reset.