Warranty and Remedies. 

(a) General.

 Powerex warrants each Compressor System, Vacuum System, Vacuum Pump, Compressor Air-End, or Powerex branded 

Accessory (collectively “Products”, individually each a “Product”) to be free from defects in material and workmanship (“Defects”) 
at the date of shipment. EXCEPT AS SET FORTH BELOW, NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED, INCLUDING ANY 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL EXIST IN CONNECTION WITH THE SALE OR USE 
OF SUCH PRODUCTS. TO THE EXTENT PERMITTED BY LAW, ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. All claims under this 
warranty must be made in writing and delivered to Powerex, or such claim shall be barred. Upon timely receipt of a claim, Powerex shall 
inspect the Product claimed to have a Defect, and Powerex shall repair, or, at its option, replace, free of charge, any Product which it 
determines to have had a Defect at the time of shipment from Powerex; provided, however, that if circumstances are such as to preclude 
the remedying of Defect by repair or replacement, Powerex shall, upon return of the Product, refund to buyer any part of the purchase 
price of such Products paid to Powerex. Freight for returning Products to Powerex for inspection shall be paid by buyer. The warranties 
and remedies herein are the sole and exclusive remedy for any breach of warranty or for any other claim based on any Defect, or non-
performance of the Products, whether based upon contract, warranty or negligence. 

b) Initial Period of Warranty – Parts and Labor.

 Powerex warrants and represents all Products shall be free from Defects for the 

fi rst twelve (12) months from the date of shipment by Powerex, or fi ve thousand (5,000) hours of use, whichever occurs fi rst. During 
such warranty period, Powerex shall be fully liable for all Defects in the Products (the “Product Defects”), i.e., all costs of repair or 
replacement, which may include “in and out” charges, so long as the Products are located in the continental United States, and the 
Products are reasonably located and accessible by service personnel for removal. “In and out” charges include the costs of removing a 
Product from buyer’s equipment for repair or replacement. 

(c) Additional Period of Warranty – Parts Only (No Labor). 

In addition to the above, Powerex warrants each Powerex branded 

Compressor Air-End, and Vacuum Pump shall be free of Defects for a period of thirty-six months from the date of shipment of Product, or 
10,000 hours of use, whichever occurs fi rst. Supplier’s repair or replacement of any Product shall not extend the period of any warranty of 
any Product. This warranty applies to the exchange of part(s) found to be defective by an Authorized Powerex Service Center only.

(d) Coverage.

 The above mentioned warranty applies to Powerex manufactured units or systems only. 

(e) Exceptions.

 Notwithstanding anything to the contrary herein, Powerex shall have no warranty obligations with respect to Products: 

(i)  that have not been installed in accordance with Powerex’s written specifi cations and instructions;

(ii)  that have not been maintained in accordance with Powerex’s written instructions; 

(iii)  that have been materially modifi ed without the prior written approval of Powerex; or

(iv)  that experience failures resulting from operation, either intentional or otherwise, in excess of rated capacities or in an otherwise 

improper manner.

(f)

 The warranty provided herein shall not apply to: (i) any defects arising from corrosion, abrasion, use of insoluble lubricants, or 

negligent attendance to or faulty operation of the Products; (ii) ordinary wear and tear of the Products; or (iii) defects arising from 
abnormal conditions of temperature, dirt or corrosive matter; (iv) any OEM component which is shipped by Powerex with the original 
manufacturer’s warranty, which shall be the sole applicable warranty for such component.

Limitation of Liability.

 TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, NOTWITHSTANDING ANYTHING TO THE CONTRARY 

HEREIN, UNDER NO CIRCUMSTANCES SHALL POWEREX BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTAL, PUNITIVE, SPECULATIVE OR 
INDIRECT LOSSES OR DAMAGES WHATSOEVER ARISING OUT OF OR IN ANY WAY RELATED TO ANY OF THE PRODUCTS OR GOODS SOLD 
OR AGREED TO BE SOLD BY POWEREX TO BUYER. TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, POWEREX’S LIABILITY IN ALL 
EVENTS IS LIMITED TO, AND SHALL NOT EXCEED, THE PURCHASE PRICE PAID.

Warranty Disclaimer.

 Powerex has made a diligent effort to illustrate and describe the Products in this literature accurately; however, 

such illustrations and descriptions are for the sole purpose of identifi cation, and do not express or imply a warranty that the Products are 
merchantable, or fi t for a particular purpose, or that the Products will necessarily conform to the illustrations or descriptions.

Product Suitability. 

Many jurisdictions have codes and regulations governing sales, construction, installation, and/or use of Products for 

certain purposes, which may vary from those in neighboring areas. While Powerex attempts to assure that its Products comply with such 
codes, it cannot guarantee compliance, and cannot be responsible for how the product is installed or used. Before purchase and use of a 
Product, please review the Product applications, and national and local codes and regulations, and be sure that the Product, installation, 
and use will comply with them.

Claims.

 Claims pertaining to the Products, with the exception of warranty claims, must be fi led with Powerex within 6 months of the 

invoice date, or they will not be honored. Prices, discounts, and terms are subject to change without notice or as stipulated in specifi c 
Product quotations. All agreements are contingent upon strikes, accidents, or other causes beyond our control. All shipments are 
carefully inspected and counted before leaving the factory. Please inspect carefully any receipt of Products noting any discrepancy or 
damage on the carrier’s freight bill at the time of delivery. Discrepancies or damage which obviously occurred in transit are the carrier’s 
responsibility and related claims should be made promptly directly to the carrier. Returned Products will not be accepted without prior 
written authorization by Powerex and deductions from invoices for shortage or damage claims will not be allowed. 

UNLESS OTHERWISE 

AGREED TO IN WRITING, THESE TERMS AND CONDITIONS WILL CONTROL IN ANY TRANSACTION WITH POWEREX

 any different 

or confl icting terms as may appear on any order form now or later submitted by the buyer. All orders are subject to acceptance by 
Powerex.

Summary of Contents for SED1007

Page 1: ...rex Oilless Rotary Scroll Air Compressor has advanced scroll compressor technology through the development of a completely oilless unit The Powerex Scroll Compressor offers a dynamically balanced air end which insures vibration free operation The rotary design permits a continuous 100 duty cycle No oil separation oil filtration or inlet valves are required on the Powerex Scroll unit The compressor...

Page 2: ...rstand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution indicates a potentiall...

Page 3: ... HOT parts of the compressor such as the air end discharge pipe aftercooler motor etc 7 Keep flammable gases away from the compressor Parts of the compressor become very hot during operation and the vapors from flammable gases may cause the unit to explode 8 Never use flammable or toxic solvents to clean the compressor or any of the unit s parts 9 Do not remove or tamper with any safety devices gu...

Page 4: ...can clog the intake filter and or intake metal mesh 2 The area should be free of excessive dust toxic or flammable gases moisture and direct sunlight 3 Never install the compressor where the ambient temperature is higher than 104 F or lower than 32 F or where humidity is high High humidity will cause electrical short circuit and rusting of components 4 Clearance must allow for safe effective inspe...

Page 5: ...hart 2 as a guideline for sizing the air receiver 1 Make sure the piping is lined up without being strained or twisted when assembling the piping for the scroll compressor 2 Appropriate expansion loops or bends should be installed at the compressor to avoid stresses caused by changes in hot and cold conditions 3 Piping supports should be anchored separately from the compressor to reduce noise and ...

Page 6: ...e on a three phase unit turn the unit off the unit is running backwards Have a qualified electrician switch the breaker OFF and exchange two out of three phases of electric source 8 Check the discharge pressure Also make sure the air pressure rises to the designated pressure setting by checking the discharge pressure gauge CONTROL LOGIC SEQUENCING ORDER Since the compressors are designed using mul...

Page 7: ...me and restarts the air end whose operating time has been shorter thus resulting in equalization of operating time of each air end and operation with a min quantity of air ends in accordance with air consumption and energy saving operation by eliminating waste of electricity 2 Prevention of long term operation When operating time of an air end exceeds the initial setting time it changes operation ...

Page 8: ...e each pump starts 3 Service Mode In order to select Service Mode push Mode Selector Switch so that Service Mode light is illuminated By Item Selector Switch you can determine causes and conditions when problems occur as indicated in Charts 5 and 7 It functions only when compressor stops 4 Set Mode Push Mode button so that Set Mode light is illuminated Item button can show each of the set contents...

Page 9: ... If the unit has no air end to display the indicator will always display underline Operating condition of Unit No 1 SEO and SEH series Displays operating condition of present Unit No 1 left side which consists of air ends no 1 4 Display contents are the same as illustrated above Operating condition of Unit No 2 SEO and SEH series Displays operating condition of present Unit No 2 right side which c...

Page 10: ... in C when emergency stops occur This display means 58 C When air end temperature is less than 15 C or other failure like cut of temperature sensor occurs displays Operating Time Shows Operating Time in x 10 hours when emergency stops occur This display means 230 hours Operating Mode Shows Operating Mode in number when emergency stops occur Refer to Chart 9 for Operating Mode Chart 5 Caution and S...

Page 11: ... and inspection in terms of 10 hours The first figure is 980 480 for high pressure models and decreases as operating time becomes longer Group Control Shows set situation of Group Control means that Group Control mode OFF is set means that Group Control mode ON is set If Group control mode ON is set ON OFF button does not work When either displays it can be changed by pushing reset switch Chart 8 ...

Page 12: ...the standard maintenance schedule This will allow you to spread the cost of maintenance over period of times Another alarm will activated at 9 800 hours INSTALLATION PROCEDURE In the same way as stated in the above to install power outage reset connector insert attached the Early Caution maintenance connector into CN26 on circuit board Caution Troubleshooting Guide When caution occurs caution numb...

Page 13: ...ature compressor air end stops See Chart 12 EX32 Rise of current If current becomes very high EX32 displays and compressor stops See Chart 13 EX41 Emergency stop by high pressure When pressure is higher than cut out pressure by 15 psig E41 displays and compressor stops Only SEH and SEO series EX60 EX61 EX63 Communications failure between the main panel circuit board and circuit board on each Unit ...

Page 14: ...nd reengage the circuit breaker Replace circuit board It starts but then stops E21 or E22 are displayed High ambient temperature or bad ventilation Clogging of aftercooler fins or intake wire screen Failure of ventilating fan Damage to intake hose Cooling passage of air end clogs High exhaust pressure Improve installation environment and ventilation Clean Replace Replace Inspect Inspect E32 is dis...

Page 15: ... SEH300720BHP SEH300730B SEH300730BHP SEH300740B SEH300740BHP 5 5 5 5 5 5 208V 3 208V 3 230V 3 230V 3 460V 3 460V 3 16 7 16 7 15 2 15 2 7 6 7 6 100 100 91 91 47 47 SEO400720B SEO400720BHP SEO400730B SEO400730BHP SEO400740B SEO400740BHP 5 5 5 5 5 5 208V 3 208V 3 230V 3 230V 3 460V 3 460V 3 16 7 16 7 15 2 15 2 7 6 7 6 134 134 121 121 61 61 Branch Circuit Protection Table B Branch circuit protection ...

Page 16: ... and bolts and then the fixed scroll from the air end 3 Grease all three pin crank bearings as indicated on the grease delivery Chart 14 above Use only Powerex genuine grease Part IP600000AV or equivalent Pump grease gun before feeding to eliminate air from grease passage of the needle adapter NOTE Each pump of the grease gun equals 0 65g of grease The volume of grease is less after the 2nd pump s...

Page 17: ...r OS or Orbit Scroll so that there will be no clearance at the tip start section See Figure 11 and 12 2 Insert so that new LP tip seal will contact closely with HP tip seal inside Scroll Groove Insert approxi mately half of the LP tip seal and remove the tip seal to confirm that a notch in the tip seal has been created This will prevent movement during installation See Figure 8 3 Repeat the same p...

Page 18: ...ssemble Fixed Scroll set to the Orbit Scroll Tighten nuts and bolts temporarily and confirm if pump pulley rotates smoothly by hand and tighten them firmly Tightening torques are NOTE Assemble so that dust seal and tip seal will not drop between Orbit Scroll set and Fixed Scroll set Dust Seal Back up Tube Figure 14 Bolt Torque First Second 17 in lb 265 in lb ...

Page 19: ...eriorated Check valve Inspect Confirm operation by watching pump shut off Safety Valve Confirm operation Every 500 hours or less Ventilation Fan Inspect Replace if malfunctions Pulley Inspect groove Repair if abnormal wear is detected Motor Inspect Replace if abnormal noise is detected Intake hose Replace Air Hose Inspect replace After Cooler Clean outside Every 5000 hours or less O ring Replace O...

Page 20: ...e top panel from the scroll cabinet to access the operating panel Remove the plastic cover from the backside of the operating panel Lift the expansion PCB from the operating panel 3 Output wires should be connected between terminals 3 and 4 The dry contacts are normally open when there is a fault the contacts close The contact rating is as follows 200 V AC 1A maximum 4 For larger load devices such...

Page 21: ... Enclosure Air Compressors 2 TI 2 TI 4 T2 4 T2 6 T3 6 T3 1 2 3 4 1 4 1 4 2 4 2 4 3 4 3 4 4 4 4 6 7 1 7 1 7 2 7 2 13 13 14 14 15 15 16 16 11 11 9 12 12 10 10 8 5 17 17 Figure 16 Parts Diagram SET1507E SET1507EHP ...

Page 22: ...22 Scroll Enclosure Air Compressors 6 T3 4 T2 2 TI 1 2 3 4 1 4 2 4 3 4 4 6 7 1 7 2 13 14 15 16 11 9 12 10 8 5 17 7 3 Figure 17 Parts Diagram SEQ2007E SEQ2007EHP ...

Page 23: ...2899060 92899060 92899060 92803070 92803070 1 7 2 Intake hose 2 92805070 92805070 92805070 92805070 92899060 92899060 1 2 2 7 3 Intake hose 3 N A N A N A N A 92805070 92805070 1 8 Temperature transducer 02801001 02801001 02801001 02801001 02801001 02801001 2 3 4 9 Pressure sensor 97992133 97992133 97992133 97992133 97992133 97992133 1 10 Check valve CV 157 CV 157 CV 157 CV 157 CV 157 CV 157 2 3 4 ...

Page 24: ...24 Scroll Enclosure Air Compressors 4 3 1 6 11 2 9 12 7 5 10 8 Figure 18 Service Parts Diagram ...

Page 25: ...uct 2 02519042 02519042 1 6 Fan Cover IP601700AV IP601700AV 1 7 Fan Dust Gasket 1 IP601900AV IP601900AV 1 8 Heat Insulation Pipe IP602000AV IP602000AV 1 9 Fan Duct Gasket 2 IP602400AV IP602400AV 1 10 Long Nipple 96647011 96647011 1 11 Dust Cap IP603500AV IP603500AV 1 12 Tip Seal Set 92832070 92832080 1 Grease Gun Kit IP616201AJ IP616201AJ Grease Gun IP616101AJ IP616101AJ Grease IP600000AV IP600000...

Page 26: ...26 Scroll Enclosure Air Compressors Maintenance Service Record Date Maintenance Performed Replacement Components Required ...

Page 27: ...27 Scroll Enclosure Air Compressors Notes ...

Page 28: ... s written instructions iii that have been materially modified without the prior written approval of Powerex or iv that experience failures resulting from operation either intentional or otherwise in excess of rated capacities or in an otherwise improper manner f The warranty provided herein shall not apply to i any defects arising from corrosion abrasion use of insoluble lubricants or negligent a...

Reviews: