The following information is to be included in the PWR-100154 User Guide to accompany the 
product  on  a  printed  insert.  For  readability,  the  product  is  described  as  the  PEEX  tX 
Transmitter and PEEX tX in this guide.   
 
N.B.  The  PEEX  tX  is  a  professional  part  of  the  PEEX  system  which  is  only  available  for 
installation and use by trained operators.  Operators must confirm that the radio channels 
selected for use are allowed by the country specific regulations before enabling transmission. 
 
There will be five main elements covered, Radio Specifications; Installation; Use; Status and 
Care.   
 

Radio Specifications: 

 

Approved for Use Country List 

Austria 

Hungary 

Portugal 

Belgium 

Iceland 

Romania 

Bulgaria 

Ireland 

Slovakia 

Croatia 

Italy 

Slovenia 

Cyprus 

Latvia 

Spain 

Czech Republic 

Liechtenstein 

Sweden 

Denmark 

Lithuania 

Switzerland 

Estonia 

Luxembourg 

Turkey 

Finland 

Malta 

United Kingdom 

France 

Netherlands 

United States of 
America 

Germany 

Norway 

Canada  

 Greece 

Poland 

Australia & New 
Zealand  

 

DFS 

Dynamic Frequency Selection 

TPC 

Transmit Power Control 

e.i.r.p 

effective (or equivalent) isotropic radiated power 

PSD 

Power Spectral Density 

COP 

Conducted Output Power 

LSB 

Listen before talk 

 

Summary of Contents for PEEX PWR-100154

Page 1: ...d by the country specific regulations before enabling transmission There will be five main elements covered Radio Specifications Installation Use Status and Care Radio Specifications Approved for Use...

Page 2: ...W with antenna gain 6dBi FCC 15 407 a 1 i ii Radar detection No FCC 15 407 h 2 TPC No FCC 15 407 h 1 LSB No N A 5250 5350 MHz Available 20 MHz channels 52 56 60 64 Section in standard Maximum PSD 11 d...

Page 3: ...uding antenna gain e i r p 23 dBm no TPC ETSI EN 301 893 Table 2 Radar detection No ETSI EN 301 893 4 2 6 1 2 TPC No ETSI EN 301 893 4 2 3 1 2 LSB Yes ETSI EN 301 893 4 2 7 CAUTION The 5150 to 5250 MH...

Page 4: ...rdance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does c...

Page 5: ...ry Canada Operation is subject to the condition that this device does not cause harmful interference Cet appareil est conforme la norme RSS 310 d Industrie Canada L op ration est soumise la condition...

Page 6: ...25 MHz doit tre conforme la limite de la p i r e iii le gain maximal d antenne permis pour les dispositifs utilisant la bande de 5 725 5 850 MHz doit tre conforme la limite de la p i r e sp cifi e pou...

Page 7: ...on and avoid obstructing with the connection of the clamp to tubing Please make sure that the M12 Hex socket bolts cannot enter further than 25mm into the mounting plate 4 The PEEX tX is water resista...

Page 8: ...an be inserted into either one of these sockets 11 If the Ethernet is to be looped through the PEEX tX to another device then suitable Ethernet cable capable of supporting 100base T networking can be...

Page 9: ...ut are not currently used 17 All other statuses are only available via the PEEX muX Multiplexer see separate document Care 18 To keep your PEEX tX clean use a damp cloth to remove any marks and then d...

Reviews: