BATTERY CHARGING (230V IP65 CHARGER)
Check the battery fluid levels and charge in a well ventilated area, only
if Lead Acid batteries are fitted (not required for maintenance free AGM
batteries).
The battery charger is located under the checkerplate cover (
Pic A
)
.
The charging lead is fitted with a black 230V plug and is located on the
exterior of the machine base (
Pic B
)
. The input voltage is 180-265V AC.
Ensure the battery isolator is switched off when charging.
Plug the charger into an available power supply and ensure the “low”
LED illuminates (
Pic C
). If flashing, a fault is indicated. Disconnect and
reconnect to the mains supply. If flashing continues seek technical support.
The LEDs will illuminate in sequence and when the “full” LED is
illuminated the charge is complete.
Additionally, the battery charge indicator on the pendant controller will
indicate charge level. The charge is complete when the 2 Green LEDs are
illuminated, if the LED indicator is fitted to the pendant controller (
Pic D
)
,
or the pointer is fully over to the right, if the Dial indicator is fitted to the
pendant controller (
Pic E
)
.
The battery charger can be connected to the mains supply at any
time or left for extended periods.
The machine can be operated when the charger is connected, although
this is not recommended.
All mains supply should be protected with a suitable RCD.