BEARING
The generator rotor assembly is suspended on a shielded factory lubricated ball
bearing. A visual inspection of the bearing is recommended at typical service intervals.
If signs of abnormal wear or leakage are observed, the bearing should be replaced.
Never use liquids of any kind to clean the generator end and bearing.
STATOR ASSEMBLY
The stator assembly consists of laminations of steel mounted in a rolled steel
frame. Random wound stator coils are fitted into the insulated slots.