Operating Instructions

Form No. 102838

PROBLEM                                   CAUSE                                         SOLUTION

Pump builds pressure but cannot
maintain pressure.

Pump will not build full pressure

1.   Check to see if there are any

external leaks. If no oil leakage 
is visible, the problem is internal.
If using a double-acting cylinder,
remove it from the system to 
ensure that the leak is not in the 
cylinder.

2.   To test for a leaking control 

valve lift the pump from the 
reservoir but keep the filter in 
the oil. Remove the drain line to 
see if the oil is leaking from the 
valve. If the valve is not leaking, 
the internal check valve could 
be leaking. Refer to the note 
concerning checking for oil leaks
at the beginning of this Trouble-
shooting Guide.

1.   Check for external leakage.

2.   Check the relief valve setting.

3.   Look for internal leakage in

double-acting cylinders.

4.   Check for leaks in the flow 

control valve.

5.   Inspect the pump for internal 

leakage. Check high pressure 
pump inlet or outlet ball checks.

6.   Sheared key(s).

1.   Seal leaking pipe fittings with 

pipe sealant.

2.   Clean, reseat or replace flow 

control valve parts. If the internal
check valve(s) are leaking, the
pump must be dismantled and 
the seat areas repaired, poppets
replaced, etc.

1.   Seal faulty pipe fitting with pipe 

sealant.

2.   Lift the pump from the reservoir, 

but keep the filter immersed in 
oil. Note the pressure reading 
when the relief valve begins to
open. If functioning normally, it 
should start to leak off at relief 
valve pressure.

3.   Remove the cylinder from the

pump. If the pump builds full 
pressure, the cylinder is
defective.

4.   Clean and reseat or replace 

parts.

5.   Same procedure as above, but 

look for leads around the entire
inner mechanism. If there are
no visible leaks, the high 
pressure pump subassembly 
may be leaking. Remove all 
parts. Check the valve head 
assembly body for any damage
to the seat area. Clean and 
reseat if necessary. Inspect for 
damage and replace parts if 
necessary, then reassemble.

6.   Replace.

Sheet No.

3 of 3

Rev. 7

Date: 25 May 2012

Summary of Contents for PE30-HOGEN

Page 1: ...ve attached equipment Stress may damage the hose and cause personal injury Hose material and coupler seals must be compatible with the hydraulic fluid used Hoses also must not come in contact with corrosive materials such as creosote impregnated objects and some paints Consult the manufacturer before painting a hose Never paint the couplers Hose deterioration due to corrosive materials may result ...

Page 2: ...used to seal hydraulic connections if only one layer of tape is used Apply the tape carefully two threads back to prevent it from being pinched by the coupler and broken off inside the system Any loose pieces of tape could travel through the system and obstruct the flow of oil or cause jamming of precision fit parts Filling the Reservoir NOTE This pump has been shipped without oil in the reservoir...

Page 3: ... free of dirt and grime 4 Keep the filler cap clean and unobstructed at all times 5 Equipment connected to the pump must be kept clean 6 Use only Power Team hydraulic fluids in this pump Change as recommended Draining and Cleaning the Reservoir IMPORTANT Clean the pump exterior before the pump interior is removed from the reservoir 1 Remove the screws that fasten the pump assembly to the reservoir...

Page 4: ...le acting cylinder 7 Cold oil or oil is too heavy Hydraulic oil is of a higher viscosity than necessary 8 Relief valve or low pressure unloading valve out of adjustment 9 Reservoir capacity is too small for the size of the cylinder s used 10 Defective directional valve 11 Sheared drive shaft key s 12 Vacuum in reservoir 1 With all cylinders retracted fill reservoir to 1 of fill hole 2 Check quick ...

Page 5: ...nternal leakage Check high pressure pump inlet or outlet ball checks 6 Sheared key s 1 Seal leaking pipe fittings with pipe sealant 2 Clean reseat or replace flow control valve parts If the internal check valve s are leaking the pump must be dismantled and the seat areas repaired poppets replaced etc 1 Seal faulty pipe fitting with pipe sealant 2 Lift the pump from the reservoir but keep the filte...

Page 6: ...d to cylinder s or quick disconnect couplings 2 Defective valve 1 Relief valve not properly set 1 Check the cylinders for broken return springs and check couplers to ensure that they are completely coupled Occasionally couplers have to be replaced because one check does not stay open in the coupled position 2 Check valve operation and inspect parts Replace if necessary 1 Adjust the relief valve HY...