POWER SMITH PLCL10BC Operator'S Manual Download Page 5

5

English

•  Do not charge alkaline batteries.
•  Do not short battery terminals.
•  Do not mix new and old batteries. Replace all batteries 

at the same time.

•  Use only manufacturer recommended batteries.
•  Do not mix the brand or type of batteries.
•  Properly dispose of all batteries at a recycling center 

or per local code. More information regarding battery 

disposal in U.S. and Canada is available at; http://www.

rbrc.org/index.html,  or  by  calling  1-800-822-8837 

(1-800-8BATTER)

•  Do not dispose of batteries in fire.
•  Keep batteries out of reach of children.
•   Remove batteries if the tool will not be used for several 

months.

•   Install batteries in the correct polarity. Positive (+) and 

Negative (-) polarity are marked on the battery and the 

tool.

PREPARATION

BATTERY InSTALLATIOn

1.  Push tab to open battery compartment cover (5).

2.  Insert batteries with the correct polarity. Match the (+) 

and (-) symbol on the inside of the compartment with 

the corresponding symbol on the batteries.

3.  Close the battery compartment cover.

OPERATION

The  tool  is  intended  for  determining  level  and  plumb 

alignment, and checking horizontal and vertical reference 

lines. 
The tool is designed for indoor use only.
Extreme  temperature  changes  can  reduce  the 

accuracy  of  the  laser. Allow  the  tool  to  adjust  to  the 

ambient temperature of the work environment before 

using. Do not subject the laser to extremely cold or hot 

environments.
Make reference marks at the center of the laser line.
Turn the tool off when not in use.

SELF-LEVEL LOCk

The  tool  has  a  self-leveling  function  that  automatically 

levels the laser lines within 5 seconds if the tool is within 

±4° of horizontal. 
To  active  the  self-leveling  function,  slide  the  Self-Level 

Lock  (1)  all  the  way  up  to  "ON"  position.  It  actives  the 

laser simultaneously. Two crossed laser lines will appear 

on the work surface. 

The Leveling Indicator (3) on the top of the tool indicates 

the  status  of  the  self-leveling  function.  A  green  light 

indicates the laser line is self-levelled. A red light indicates 

the laser line is not self-levelled. 
To  deactivate  the  self-leveling  function,  slide  the  Self-

Level Lock down to "OFF" position. It will turn the tool off.

POWER / MODE SELECTOR BUTTOn

The Power/Mode Selector Button (2) is located on the top 

of the tool. 
The tool has three laser line patterns: Crossed, Horizontal 

and Vertical. The laser line pattern can be selected when 

either self-leveling is ON or OFF. 
When the Self-Level Lock is ON, the laser has been already 

activated. The Power/Mode Selector Button is for selecting 

the laser line pattern only. Press the Power/Mode Selector 

button repeatedly to choose the desired laser line pattern. 
When the Self-Level Lock is OFF, the tool can be turned on 

by pressing the Power/Mode Selector Button. Repeatedly 

press  the  button  to  select  the  laser  line  pattern  or  turn 

the tool off. 

SELF-LEVELInG MODE

To Set the Tool in Self-Leveling Mode:
1.  Place the tool on a flat and solid support or on a tripod. 

2.  Slide  the  Self-Level  Lock  "ON"  to  activate  the  self-

leveling function. Two crossed laser lines will appear on 

the work surface. 

3.  Check  the  Leveling  Indicator.  If  it  is  green,  the  self-

leveling  function  is  at  work.  If  it  is  red  and  the  laser 

lines are flashing, the tool is outside of the ±4° self-

leveling  range  and  will  require  adjusting  until  the 

indicator appears green.

nOn-SELF-LEVELInG MODE

The  Non-Self-Leveling  Mode  is  for  alignment  purposes 

and for projecting reference laser lines. It cannot be used 

to perform leveling functions. In this mode, the Leveling 

indicator (3) always appears red.

To Set the Tool in Non-Self-Leveling Mode:

1.  Place the Self-Level Lock in the "OFF" positon.
2.  Press  the  Power/Mode  Selector  Button  (2)  to  turn 

the tool on. The initial laser projection is two crossed 

laser lines. You may select other laser line pattern by 

pressing the Power/Mode Selection Button repeatedly. 

3.  Rotate the tool until the desired laser reference line is 

projected on the work surface.

USInG THE ADJUSTABLE BASE 

The tool kit comes with an Adjustable Base (6). It has a 

Base Foot (7) for placing on a flat surface, a 1/4" female 

threaded  screw  insert  on  the  bottom  for  attaching  on  a 

tripod, and a Wall Key (10) and Magnets (9) on the back for 

mounting on a wall. The Adjustable Base is able to adjust 

the height within a 3" range. 

BATTERy SAFETy INSTRUCTIONS

OPERATION

Summary of Contents for PLCL10BC

Page 1: ...ISÉES LÁSER CRUZADO DE AUTONIVELACIÓN 888 552 8665 Toll Free Help Line www powersmithPRODUCTs com SAVE THIS MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS CONSERVER CE MANUEL POUR FUTURE RÉFÉRENCE Operator s Manual Manuel d utilisation Manual del operario ...

Page 2: ...2 fIG 2 1 3 2 4 6 8 7 11 12 9 10 7 fIG 1 5 ...

Page 3: ...3 fIG 3 fIG 4 fIG 5 fIG 6 x x ...

Page 4: ... Avoid exposure Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Never point the laser towards aircraft or vehicles It is unsafe and illegal Never point the laser towards people or animals Keep the tool away from children Do not use the tool around children This is not a toy Tool service must be performed by a ...

Page 5: ...lf leveling function slide the Self Level Lock down to OFF position It will turn the tool off POWER MODE SELECTOR BUTTON The Power Mode Selector Button 2 is located on the top of the tool The tool has three laser line patterns Crossed Horizontal and Vertical The laser line pattern can be selected when either self leveling is ON or OFF When the Self Level Lock is ON the laser has been already activ...

Page 6: ...termine the height at which you want the first row of tile to begin Align the intersection of the crossed horizontal and vertical laser lines at that location Install the first tile so it aligns with both the horizontal and vertical laser lines Continue installing the tile along either the horizontal or vertical laser line MAINTENANCE WARNING Do not turn the laser on while cleaning the lens Seriou...

Page 7: ...es lésions aux yeux pourraient survenir EXPOSITIONAU RAYONNEMENT Ne PAS désassembler ou modifier le laser Cet outil ne contient pas de pièces pouvant être réparées RAYONNEMENT DANGEREUX Éviter toute exposition L utilisation de commandes ou de réglages ou l exécution de méthodes autres que celles précisées aux présentes peut avoir pour conséquences une exposition dangereuse au rayonnement Ne jamais...

Page 8: ...e trouve dans une marge de 4 de l horizontale Pour activer la fonction autonivelante glisser la serrure autonivelante 1 complètement vers le haut à la position de marche Cela active le laser simultanément Deux lignes laser croisées apparaîtront sur la surface de travail L indicateur de niveau 3 sur le dessus de l outil indique l état de mise à niveau automatique Un témoin allumé en vert indique qu...

Page 9: ...ce peuvent être utilisées ensemble pour une plus grande polyvalence de l outil Raccorder la pince à la base en vissant la vis de 6 35 mm 1 4 po dans la partie inférieure de la base réglable MONTAGE SUR TRÉPIED FIG 3 Un trépied non inclus fournit un support stable dont la hauteur est réglable Fixer l outil sur un trépied en vissant la vis de 6 35 mm 1 4 po au bas de l outil Voir la fig 3 VÉRIFICATI...

Page 10: ...igine est couvert par cette garantie mais elle n est pas transférable Avant de renvoyer votre l produit au magasin d achat s il vous plaît appelez sans frais la ligne d aide pour les solutions possibles LES ACCESSOIRES COMPRIS DANS CE KIT NE SONT PAS COUVERTS PAR LA GARANTIE DE 2 ANS LIGNE D ASSISTANCE Pour vos questions sur ce produit ou un autre de PowerSmith veuillez utiliser en Amérique du Nor...

Page 11: ...az en la apertura de salida del haz ni en una superficie reflejante tal como un espejo Este es un láser de Clase 2 Esto puede causar daño grave a los ojos EXPOSICIÓN LA IRRADIACIÓN NO desarmar ni modificar esta herramienta láser No hay componentes internos que puedan repararse IRRADIACIÓN PELIGROSA Evitar la exposición al rayo El uso de controles y o regulaciones del dispositivo que no sean las aq...

Page 12: ...a herramienta está a 4 de la horizontal Para activar la función de autonivelación deslizar al seguro de autonivelación 1 hacia arriba hasta la posición ON Esto activa el láser simultáneamente Aparecerán dos líneas láser cruzadas sobre la superficie de trabajo El indicador de nivelación 3 arriba de la herramienta indicará el estado de la autonivelación Una luz verde indica que el láser está autoniv...

Page 13: ...la parte inferior de la base Ver Fig 2 MONTAJE EN UN TRÍPODE FIG 3 Un trípode brinda un mecanismo de apoyo estable y de altura regulable Acoplar la herramienta al trípode con un tornillo de 1 4 enroscado a la parte inferior de la herramienta Ver Fig 3 APLICACIONES VERIFICACIÓN DE LA ALINEACIÓN FIG 4 La herramienta puede sostenerse contra la pared para verificar la alineación Para realizar alineaci...

Page 14: ...u producto para almacenar la ubicación de la compra por favor llame gratis a la línea de ayuda para las posibles soluciones LOS ACCESORIOS INCLUIDOS CON ESTE JUEGO NO TIENEN 2 AÑOS DE GARANTÍA LÍNEA DE AYUDA HELP LINE Para preguntas acerca de este o cualquier otro producto PowerSmith Llame gratuitamente al teléfono 888 552 8665 O visite nuestro sitio web www powersmithproducts com Richpower Indust...

Page 15: ...15 NOTES ...

Page 16: ...Richpower Industries Inc 736 Hampton Road Williamston SC USA www richpowerinc com 2017 03 V01 ...

Reviews: