6.
Generator usage
WARNING:
Ensure grounding is connected (grounding Rod). Check with an
electrician in case of any doubts.
WARNING:
Never connect the 230 voltage output of the equipment to a
building or house (not even during a power outage). The return of the main
network would clash with the generator's voltage and cause serious damage to the
equipment or even a fire.
WARNING:
Do not connect in parallel with other generators to add power,
both would result damaged and will fire hazard.
NOTE:
If a cable extension is needed, make sure you use a good quality
rubber extension and appropriate section: Below the minimum recommendations
In any case consult your electrician, he is the one to determine the cable in
function of distance and tension.
60m cable length: minimum use a 2mm
2
cable
100m cable length, minimum use a 2.5mm
2
cable
NOTE:
Devices that use an engine such as compressors, water pumps,
saws, radials, etc. require up to 3 times more power for start up. For example, a
500 W water pump would need a 1500 W generator for start up. Verify that
charges upon connection do not exceed the maximum power of the group
according to this indication.
GROUNDING
GROUNDING SYMBOL
Summary of Contents for GUARDIAN S6-ATS
Page 2: ......
Page 8: ...6 Español FILTRO DE AIRE ESTRANGULADOR VALVULA GASOLINA BATERIA ...
Page 52: ......
Page 58: ...55 English AIR FILTER CHOKE GASOLINE VALVE BATTERY ...
Page 102: ......
Page 108: ...104 Português FILTRO DE AR ESTRANGULADOR VÁLVULA GASOLINA BATERIA ...
Page 153: ......
Page 154: ...51 POLIGONO INDUSTRIAL NEINVER CALAHORRA LA RIOJA CONTACTO INFORMAÇÕES INFO SG GROUP ES ...