Electromagnetic Compatibility (EMC)
Precautions
The pro7HC™ models are suitable for
use in all establishments, including
domestic establishments and those
directly connected to the public low-
voltage power supply network that
supplies buildings used for domestic
purposes. Both models have been tested
against, and have passed the applicable
requirements of relevant electromedical
standards, including EN 60601-1-2:2007.
The pro7HC™ models must emit
electromagnetic energy in order to
perform their intended function. Nearby
electronic equipment may be affected
by this emission. Similarly the pro7HC™
models may themselves be affected by
electromagnetic emissions from other
equipment in the vicinity.
The pro7HC™ models are intended for
use in the electromagnetic environment
specified below. The customer or user of
the pro7HC™ model should assure that
they are used in such an environment:
– Floors should be wood, concrete or
ceramic tile. If the floor is covered with
synthetic material, the relative humidity
in the room should be at least 30%.
– Mains power quality should be that
of a typical domestic, commercial or
hospital environment as appropriate.
– The pro7HC™ should not be used during
power mains interruptions
– Power frequency magnetic fields
should be at levels characteristic of a
typical location in a typical commercial
or hospital environment.
The pro7HC™ models are intended for
use in an electronic environment in which
radiated radio-frequency (RF) disturbances
are controlled.
The customer or user of the
pro7HC™model can help prevent
electromagnetic interference by
maintaining a minimum distance between
portable and mobile RF communications
equipment (transmitters) and the
pro7HC™ model as recommended below,
according to the maximum output power
of the communications equipment:
The adequate separation distance
to provide base immunity to RF
disturbances is 1.0m.
Retain this user manual for your future
reference.
•
•
•
•
08
09
Classification
1. Class I equipment;
2. Type B applied part;
3. IPX0;
4. Not category AP / APG equipment;
5. Mode of operation: Non-continuous Operation : 9mins on/ 3hours off
Environmental Requirements
OPERATING CONDITIONS
Temperature: 10ºC to 40ºC
Humidity: 10% to 95% RH
Pressure altitude: Normal atmospheric
conditions/ 860-1060hPa
STORAGE AND SHIPPING CONDITIONS
Temperature: 10ºC to 40ºC
Humidity: 10% to 95% RH
Pressure altitude: Normal atmospheric
conditions/ 860-1060hPa
WARNING
The device is not suitable for use in the presence of flammable anesthetic mixtures
with air or with oxygen or nitrous oxide.
The device requires no calibration.
The device is not repairable and contains no user serviceable parts.
The user must check that the equipment functions safely and see that it is in proper
working condition before being used.
The manufacturer does not require such preventive inspections by other persons.
The plug is used to disconnect from the main supply. Do not position the machine
so that it is difficult to disconnect the main plug.
Warning: To avoid the risk of electric shock, this equipment must only be
connected to a supply main with protective earth grounding.
Patient
The machine is intended for use by a diverse patient population including:
• Adult men and woman who are medically cleared and able to undertake
physical exercises such as weight baring and ground reaction force type
exercise programs. In general this applies to healthy grownups (16+ years old).
• All others users should be cleared by their physician and only use the Power
Plate under medical supervision.