Operation and installation manual
Page 82 of 96
(PVI-STRINGCOMB (-S, -MC, -S-MC) - Rev:1.0)
12.8.3 Configuration
Aux Inputs Settings
This panel allows for setting the scale factor for each of the auxiliary inputs and a
possible offset.
The scale factor is multiplied by the value of the input voltage. Therefore, a
variation in the input voltage between 0 and 10V will be displayed by default
(Scale Factor = 1) as 0-10.
The offset is added to the scaled value.
Press [Set Inputs >>] to save the values. A confirmation window of the
settings will appear.
Check that the operation has been carried out correctly and then press
[OK]: if there are any errors, press [OK] and then repeat the operation.
T_Cell input function can be switched (Ref.§9.3.3) and said input can be used for
PT100 sensor reading.