Power Fist 8142564 Owner'S Manual Download Page 6

Installation

• Ensure installation meets all applicable safety, and local and national electrical codes. Have installation

performed by a qualified, licensed electrician and building contractor. 

• All electrical work, including the earth-ground connection, should be completed by a licensed electrician.

• Any separate fuel storage or generator supply facility must be built or installed in full compliance with all

relevant local, state, and federal regulations.

• If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run

outdoors without protection to the generator and wiring conduit.

• The generator weighs 100 lbs (approx). Two or more people should assist when moving or lifting this product.

Never lift the generator using the engine or alternator lifting lugs. Connect lifting equipment to the frame of the
generator

• Before lifting the generator, ensure the lift rigging and supporting structure are in good condition, and are rated

to lift such a load.

• Keep all personnel away from the suspended generator during relocating.

• The supporting floor/ground surface should be level and strong enough to safely hold the weight of the generator.

If the floor/grounded surface is not level, strong cross members should be placed under the full length of the
generator frame at its low side.

• For trailer installation, the generator should be mounted on the center point of the trailer, over the wheels. The

trailer must be capable of supporting the weight of the generator and all contents (tools, etc.)

• Install sound-and weather-proofing only when it is not raining or snowing to avoid trapping moisture within the

generator’s area.

Mechanical

• Always make sure the power switch is in its “OFF” position. Disconnect the spark plug wire, and allow the

engine to completely cool before carrying out maintenance.

• Check for damaged parts. Before using the generator, any part that appears damaged should be carefully checked

to determine that it will operate properly and perform its intended function. Check for alignment and binding of
moving parts, any broken parts or mounting fixtures, and any other condition that may affect proper operation
technician.

• The generator is designed with guards for protection from moving parts. In any case, care must still be taken to

protect personnel and equipment from other mechanical hazards when working around the generator.

• Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach

around the safety guard for maintenance or any other reason.

• Keep hands, arms, long hair, loose clothing, and jewellery away from moving parts. Be aware that when engine

parts are moving fast they cannot be seen clearly.

• Keep access doors on enclosures closed and locked when access is not required.

• When working on or around the generator always wear protective clothing including ANSI approved safety

gloves, safety eye goggles, and safety hat.

• Do not alter or adjust any part of the generator that is assembled and supplied by the manufacturer.

• Always follow and complete scheduled engine and generator maintenance.

Summary of Contents for 8142564

Page 1: ...2 800 Watt Generator 8142564 Owner s Manual...

Page 2: ...MALFUNCTION OF THE PRODUCT IS NOT COVERED BY PRINCESS AUTO Safety Guidelines This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREV...

Page 3: ...he engine and fuel tank Fuel vapors are explosive Keep grounded conductive objects such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could...

Page 4: ...the power cord Keep power cords away from heat oil sharp edges or moving parts Replace damaged power cords immediately Damaged power cords increase the risk of electric shock When operating a power to...

Page 5: ...h is in its OFF position and disconnect the spark plug wire before making any adjustment changing accessories or storing the generator Such preventive safety measures reduce the risk of starting the g...

Page 6: ...capable of supporting the weight of the generator and all contents tools etc Install sound and weather proofing only when it is not raining or snowing to avoid trapping moisture within the generator...

Page 7: ...ot need a battery Assembly No assembly is required Operation NOTE THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE CONTROLS MENTIONED BELOW CAUTION PRIOR TO FIRST USING THE GENERATOR THE ENGINE MUS...

Page 8: ...REAKER TO ITS ON POSITION RESTART THE GENERATOR AND CONTINUE POWERING THE REMAINING TOOLS AND EQUIPMENT 3 Note The Generator features an AC Non Fuse Circuit Breaker OFF position Turn the fuel valve to...

Page 9: ...is seated tighten with a spark plug in by hand to prevent cross threading 7 After the spark plug is seated tighten with a spark plug wrench to compress the washer NOTE THE SPARK PLUG MUST BE SECURELY...

Page 10: ...MOVING IT TO THE INSTALLATION LOCATION ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR General Location Make sure to locate and install the generator outdoors where cooling air is readily ava...

Page 11: ...AC 3 spring grounded DC electrical no Gasoline engine Horsepower 6 0 HP Type 4 cycle OHV air cooled recoil start Displacement 171cc Oil capacity 0 6 quart 0 56 liter EPA approved yes Fuel Type Unleade...

Page 12: ...Bolt M6x25 63 Intake valve 64 Cylinder head 65 Bolt M6x85 66 Spark plug 67 Seal 68 Valve spring 69 Valve spring retainer 70 Valve cotter 71 Push rod 72 Push rod guide 73 Washer 6mm 74 Bolt 75 Rocker a...

Page 13: ...Parts Diagram...

Page 14: ...his certificate This certificate of conformity does not cover small non road engines imported prior to the effective date of the certificate This certificate of conformity is conditional upon complian...