Gasoline and Oil

This product requires oil and fuel. Attempting to start the engine without oil will ruin the engine and void the
warranty. Work in well ventilated areas. Keep cigarettes, flames or sparks away from the work area or where
gasoline is stored.

WARNING! GASOLINE IS EXTREMELY FLAMMABLE AND IS EXPLOSIVE UNDER CERTAIN

CONDITIONS. KEEP OUT OF REACH OF CHILDREN.

• Gasoline fuel and fumes are flammable and potentially explosive. Use proper fuel storage and handling

procedures. Always have multiple class ABC fire extinguishers nearby. 

• Keep the generator and surrounding area clean at all times.

• Fuel or oil spills must be cleaned up immediately. Dispose of fluids and cleaning materials as per any local, state,

or federal codes and regulations. Store oily rags in a covered metal container.

• Never store fuel or other flammable materials near the generator.

General Precautions

WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE INJURY OR

DEATH.

CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO RESULT IN DAMAGE TO THE

TOOL AND/OR THE ITEM YOU ARE WORKING ON.

• Do not smoke, or allow sparks, flames or other sources of ignition around the engine and fuel tank. Fuel vapors

are explosive.

• Keep grounded conductive objects, such as tools, away from exposed, live electrical parts and connections to

avoid sparking or arcing. These events could ignite fumes or vapors.

• Do not refill the fuel tank while the engine is running or while the engine is still hot. Do not operate the

generator with known leaks in the fuel system

• Excessive buildup of unburned fuel gases in the exhaust system can create a potentially explosive condition. This

buildup can occur after repeated failed start attempts, valve testing, or hot engine shutdown. If this occurs, open
exhaust system drain plugs, if equipped, and allow the gases to dissipate before attempting to restart the
generator.

• Use only engine manufacturer recommended fuel and oil.

Hot Components

WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY HOT AND REMAIN HOT FOR

SOME TIME AFTER THE ENGINE IS RUN. WEAR INSULATED GLOVES OR WAIT UNTIL
THE ENGINE AND EXHAUST SYSTEM HAVE COOLED BEFORE HANDLING THESE
PARTS.

Power Output

This generator is not designed to power sensitive electronic equipment (including computers and medical devices)
without the addition of an approved line conditioner, which is sold separately.

CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF

AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. 

Summary of Contents for 8142564

Page 1: ...2 800 Watt Generator 8142564 Owner s Manual...

Page 2: ...MALFUNCTION OF THE PRODUCT IS NOT COVERED BY PRINCESS AUTO Safety Guidelines This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREV...

Page 3: ...he engine and fuel tank Fuel vapors are explosive Keep grounded conductive objects such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could...

Page 4: ...the power cord Keep power cords away from heat oil sharp edges or moving parts Replace damaged power cords immediately Damaged power cords increase the risk of electric shock When operating a power to...

Page 5: ...h is in its OFF position and disconnect the spark plug wire before making any adjustment changing accessories or storing the generator Such preventive safety measures reduce the risk of starting the g...

Page 6: ...capable of supporting the weight of the generator and all contents tools etc Install sound and weather proofing only when it is not raining or snowing to avoid trapping moisture within the generator...

Page 7: ...ot need a battery Assembly No assembly is required Operation NOTE THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE CONTROLS MENTIONED BELOW CAUTION PRIOR TO FIRST USING THE GENERATOR THE ENGINE MUS...

Page 8: ...REAKER TO ITS ON POSITION RESTART THE GENERATOR AND CONTINUE POWERING THE REMAINING TOOLS AND EQUIPMENT 3 Note The Generator features an AC Non Fuse Circuit Breaker OFF position Turn the fuel valve to...

Page 9: ...is seated tighten with a spark plug in by hand to prevent cross threading 7 After the spark plug is seated tighten with a spark plug wrench to compress the washer NOTE THE SPARK PLUG MUST BE SECURELY...

Page 10: ...MOVING IT TO THE INSTALLATION LOCATION ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR General Location Make sure to locate and install the generator outdoors where cooling air is readily ava...

Page 11: ...AC 3 spring grounded DC electrical no Gasoline engine Horsepower 6 0 HP Type 4 cycle OHV air cooled recoil start Displacement 171cc Oil capacity 0 6 quart 0 56 liter EPA approved yes Fuel Type Unleade...

Page 12: ...Bolt M6x25 63 Intake valve 64 Cylinder head 65 Bolt M6x85 66 Spark plug 67 Seal 68 Valve spring 69 Valve spring retainer 70 Valve cotter 71 Push rod 72 Push rod guide 73 Washer 6mm 74 Bolt 75 Rocker a...

Page 13: ...Parts Diagram...

Page 14: ...his certificate This certificate of conformity does not cover small non road engines imported prior to the effective date of the certificate This certificate of conformity is conditional upon complian...

Reviews: