Powered by Safety
®
34
Usage
01.4IB.48040C
BriteSpot™ BSG3
Figure 42 Device Configuration
e. B
rite
A
lert
The G3 is equipped with a data processing
feature intended to simplify operators decision
making. BriteAlert interprets raw data and
alerts user via single BriteAlert register. The G3
will collect, interpret, and archive the data and
alerts user only when action needs to be taken.
1) BriteAlert Status Register
Each temperature channel on the G3
Conversion Module is equipped with a pair
of registers that are used to indicate that
the temperature has exceeded a predefined
threshold.
Table V BriteAlert Error Code Table
BriteAlert Status
Register Value
Description
0
OK - No action needed
system OK
1
WARNING – schedule maintenance
of the equipment – no immediate
action needed
2
ALERT – dangerous situation, shut
down the equipment
2) BriteAlert Error Code Register
There is maximum of 10 BriteAlert Error
Codes kept up to date. All error codes are
logged internally.
Table W BriteAlert Status Register
BriteAlert Error
Code Register Value
Description
01 XX
Over temperature
02 XX
Alarm - Over temperature
03 XX
BriteSpot™ error -
self diagnostics
XX is qualifier and indicates the
channel number (1-18) in HEX for-
mat, 1=CH 1,… F=CH 15, 10=CH16,
11=CH17 and 12=CH18
3) BriteAlert LCD screen (BSG3.9S only)
Below is the main BriteAlert LCD screen.
Figure 43 BriteAlert LCD Screen
Summary of Contents for BriteSpot BSG3
Page 1: ...Instruction Bulletin 01 4IB 48040C BriteSpot BSG3 Powered by Safety ...
Page 4: ...Powered by Safety BriteSpot BSG3 01 4IB 48040C This page is intentionally left blank ...
Page 10: ...Powered by Safety BriteSpot BSG3 01 4IB 48040C This page is intentionally left blank ...
Page 37: ...Powered by Safety 27 Usage 01 4IB 48040C Figure 34 LCD Menu and Navigation ...