Supplied By www.heating spares.co Tel. 0161 620 6677
17 INSTALLATION - SIDE FLUE
Manual No. 405/0101
INSTALLATION - SIDE FLUE - PAGE 17
3.11
SIDE FLUE - FIT THE FLUE/TERMINAL ASSEMBLY
Refer to Figs. 21 and 22.
Note:
As the flue/terminal assembly is not physically secured to the boiler the outer wall plate, the outer sealing plate must
be used to secure the flue/terminal assembly to the wall.
1.
Fit the outer wall plate, supplied with the flue/terminal
assembly, over the flue/terminal assembly as shown in
Fig. 21.
2.
From outside the building insert the flue/terminal
assembly into the wall and carefully push it fully home.
3.
If necessary make good the outside wall around the flue
duct.
4.
Place the outer sealing plate assembly, supplied with the
flue/terminal assembly, over the terminal as shown in Fig.
22 and mark the position of the four fixing holes.
5.
Remove the sealing plate and drill and plug the holes,
suitable for 1” lg. No.8 woodscrews.
Note:
The terminal should be covered before drilling to
prevent debris entering the terminal.
6.
Remove any covering from the terminal. Position the
sealing plate over the terminal and secure it to the wall
with four 1” lg. No.8 screws, supplied with the flue/terminal
assembly.
Fig. 21
Fig. 22
3.12
SIDE FLUE - REPLACE THE FAN ASSEMBLY
Refer to Fig. 23.
1.
Ensure that the 'O' ring is in position on the fan outlet,
then fit the flue tube sleeve, supplied with the boiler, over
the fan outlet and push it fully home.
2.
Place the fan assembly on top of the flue hood with the
outlet facing to the side from which the flue is to exit (for
right hand exit the fan will be at the front, for left hand exit
the fan will be at the back) and reconnect the leads, see
Fig. 14a, as follows:
Two violet leads to the fan motor.
Yellow lead to pressure switch No connection.
Red lead to pressure switch Nc connection.
Black lead to pressure switch C connection.
3.
With the fan assembly resting on the flue hood push it
towards the rear of the boiler locating the base of the fan
assembly under the returns at the rear of the heat
exchanger top frame (1 in Fig. 23), then slide it to the
Fig. 23
left or right to locate the flue tube sleeve on the fan outlet into the inner tube of the flue/terminal assembly (2 in Fig.
23).
4.
Secure the front of the fan assembly to the flue hood with the two screws previously removed.