Technical Data - Page 3
Nominal Boiler Ratings
Boiler
models
Output
Input
Burner setting pressure
Gas Rate
Injector Size
kW
Btu/h
kW
Btu/h
mbar
in wg
m³/h
ft³/h
mm dia.
5.5
19 000
7.3
25 000
4.1
1.65
0.70
24.7
30
2.8
8.8
30 000
11.0
37 500
9.3
3.70
1.05
37.1
8.5
29 000
11.0
37 500
6.1
2.45
1.05
37.1
40
3.1
11.7
40 000
14.7
50 000
11.2
4.50
1.40
49.3
11.4
39 000
14.8
50 500
6.7
2.65
1.42
50.1
50
3.5
14.7
50 000
18.3
62 500
10.3
4.10
1.75
61.8
14.4
49 000
18.6
63 500
8.6
3.45
1.78
62.9
60
3.7
17.6
60 000
22.0
75 000
12.2
4.90
2.10
74.2
17.3
59 000
22.0
75 000
9.6
3.85
2.10
74.2
70
3.9
20.5
70 000
25.6
87 500
13.4
5.35
2.45
86.4
20.1
68 500
25.6
87 500
10.7
4.28
2.45
86.4
80
4.1
23.4
80 000
29.3
100 000
13.9
5.56
2.80
98.7
Maximum Working Head
30.5m (100 ft)
Minimum Working Head
150mm (6 in)
Gas Supply Pressure
20mbar
Gas Supply Connection
Rc. ½ (½ in BSP Female)
Maximum Flow Temperature
82ºC
Flow/Return Connections
22 mm Copper
Water Content
1.6 litres (0.37 gal) - 30, 40, 50 & 60 Models
2.1 litres (0.46 gal) - 70 & 80 Model
Appliance Lift Weight
26.0 kg (57.3 lbs) - 30, 40, 50 & 60 Models
30.2 kg (66.6 lbs) - 70 & 80 Model
Appliance Weight Installed - Dry
32.0 kg (70.0 lbs) - 30, 40, 50 & 60 Models
35.4 kg (78.1 lbs) - 70 & 80 Model
Electricity Supply
230v ~ 50Hz Fused at 3A
Internal Fuse
Type 3.15AT
Power Consumption
80 watts (excluding pump)
Classifications
CAT 12H
C12, C32 & C71 (C71 30 - 60 models only)
IP20
SAFETY, PERFORMANCE & QUALITY
Suprima boilers have been assessed by a Government appointed Notified Body and shown to meet the
‘Essential Requirements’ of the European Gas Appliance Directive.
The Directive lays down requirements for the safety and efficiency of the appliance, together with its
design, construction, and use of materials.
It also requires the production process to be covered by an approved and monitored system of quality
assurance.
Summary of Contents for Suprima 30
Page 6: ...Installation Requirements Page 6 ...
Page 10: ...Installation Requirements Page 10 Fig 3 Fig 4 ...
Page 12: ...Flue Kits Page 12 ...
Page 13: ...Optional Extras Flues Page 13 Installation instructions included as necessary with each kit ...
Page 14: ...System and Other Kits Page 14 ...
Page 15: ...System and other Kits Page 15 ...
Page 33: ...6 Wiring Diagram Page 33 ...