Technical Data Page 3
Nominal Boiler Ratings
Boiler
Output
Input
Burner Setting pressure
Gas Rate
Injector Size
Models
kW
Btu/h
kW
Btu/h
mbar
in wg
m³/h
ft³/h
mm dia
100
28.72
98,000
35.9
122,500
13.6
5.54
3.42
120.9
3.2
Maximum Working Head
30.5 m (100 ft)
Minimum Working Head
150 mm (6 in)
Gas Supply Pressure
20 mbar
Gas Supply Connection
Rc. ½ ( ½ in BSP Female)
Maximum Flow Temperature
82°C
Flow/Return Connections
22 mm Copper
Water Content
2.1 litres (0.46 gal)
Appliance Lift Weight
34.6 kg (76.3 lbs) 100 Model
Appliance Weight Installed - Dry
39.7 kg (87.5 lbs) 100 Model
Electricity Supply
230v ~ 50Hz Fused at 3A
Internal Fuse
Type 3.15AT
Power Consumption
80 Watts (excluding pump)
Classifications
CAT 1
2
H
C12 & C32
IP20
SAFETY, PERFORMANCE & QUALITY
Suprima boilers have been assessed by a Government appointed Notified Body and shown
to meet the ‘Essential Requirements’ of the European Gas Appliance Directive.
The Directive lays down requirements for the safety and efficiency of the appliance,
together with its design, construction, and use of materials.
It also requires the production process to be covered by an approved and monitored
system of quality assurance.
Summary of Contents for Suprima 100
Page 10: ...Installation Requirements Page 10 ...
Page 12: ...Flue Kits Page 12 Installation instructions included as necessary with each kit ...
Page 13: ...Other Kits Page 13 Installation instructions included as necessary with each kit ...
Page 31: ...6 Wiring Diagram Page 31 ...
Page 32: ......
Page 34: ...7 Fault Finding Guide Page 33 ...
Page 36: ......
Page 37: ...8 Short List of Spare Parts Page 34 SUP0083D L 365mm L 365mm L 462mm L 476mm ...