![Potterton Statesman Flowsure L Installation & Service Instructions Manual Download Page 10](http://html.mh-extra.com/html/potterton/statesman-flowsure-l/statesman-flowsure-l_installation-and-service-instructions-manual_1583156010.webp)
10
Part No. 5106463
Technical Data
Fig. 6
3
2
ST00251A
N
L
N
L
N
L
N
N
E
E
L
L
N
N
L
N
L
N
L
Terminal
Block
Terminal
Block
0.47 UF Capacitor
Overheat
Burner
Lockout
Mains
On
N E L
Burner
Socket
Main
Socket
Chassis
Earth
Limit
Stat.
Boiler
Stat.
Pump
Overrun
Stat.
D.H.W.
Thermostat
L2
L1
E
N
21
3
4
2
22
2
3
Main
Supply
Connection
Colour Coding
For The Wiring
b - Blue
br - Brown
gy - Grey
r - Red
g/y - Green/Yellow
w - White
v - Violet
y - Yellow
o - Orange
p - Pink
bl - Black
b
g/y
br
r
b
b
g/y
bl
br
br
N
E
L
Live
Main Supply
Connection
L
N
S/L
S/L
Neutral
Earth
11(1)
31(11)
A2(10)
A1(2)
14(3)
34(9)
12(4)
32(8)
22(5)
24(7)
21(6)
Flow
Switch
Diverter Valve
Pump
Tray Assembly
L
L
1
1
E
E
N
N
L
L
S/L
S/L
L
L
L
N
E
Relay
br
br
v
o
b
g/y
gy
gy
y
o
r
v
o
br
bl
bl
o
r
br
br
br
br
br
b
b
b
bl
bl
b
b
p
b
g/y
b
b
br
p
gy
w
g/y
g/y
w
gy
bl
br
br
r
bl
y
b
b
LINK to be replaced
with room thermostat
L
N
CH
ON
HW
ON
1
1
1b
1a
1a
o
Electro-mech.
Clock
3 Position Switch
2 Position Switch
5
3
2
1
C.Heating
Boiler
b
br
br
gy
p
w
w
br
y
y
b
b
y
br
br
br
br
Boiler Wiring Diagram - Statesman Flowsure
Boiler Functional Flow - Statesman Flowsure
!"" #$%
& !'!""
(
) !
*+ $
& $
!,
&- (
&- ( !-
-
.-$/
*,
0,
$
(