15.0
Fault Finding
41
© Baxi Heating UK Limited 2005
Mains On
LED Light
(Green)
Boiler On
LED Light
(Green)
Lockout
LED Light
(Red)
Live & Neutral Reversed
Incoming Live and Neutral
reversed.
Go to
Ignition Lockout
section
of the fault finding instructions.
Go to
Fan Lockout
section of the fault finding
instructions.
Go to
Thermistor
section
of the fault finding
instructions.
Low Electrical Supply
Incoming Voltage less than
180V. Check System
Controls & System Wiring.
Otherwise contact Electricity
Provider.
LV Wiring Harness
Ensure the small 8 way
connector is securely plugged
into the PCB. If the fault
persists replace wiring harness.
PCB Fault
Replace PCB.
PCB Fault
Replace PCB.
PCB Fault
Replace PCB.
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Go to
Electrical Supply
section of the fault finding
instructions.
Go to
Dry-Fire
section of the fault finding
instructions.
Go to
Overheat Lockout
section of the fault finding
instructions.
NOTE: The fan is supplied with 325 Vdc.
Fan Fault Finding should only be carried out after the
boiler has been electrically isolated.
General Fault Finding should only be carried out by
someone who is appropriately qualified.
Condensate
Pump
LED Light
(Green)
Lights
Off Off Off Off
Lights
Off On Off
*
Lights
On Off
* *
Lights
On Off On Off
Lights
On Off Off
*
Lights
On Off
*
*
Lights
On On Off
*
Lights
Off Off
*
*
Lights
On On On Off
Lights
On Off
*
*
Lights
On On Off
*
Lights
On On Off
*
Go to
Condensate Pump
section of the fault finding
instructions.
YES
Lights
On On
* *
denotes LED flashing
*