Publication No. 5106228

2

User’s Instructions

TM

About Safety

Benchmark Installation, Commissioning and Service
Record Log Book

Potterton is a member of the Benchmark initiative and fully
supports the aims of the programme.

Benchmark has

been introduced to improve the standards of installation
and commissioning of central heating systems in the UK
and to encourage the regular servicing of all central
heating systems to ensure safety and efficiency.

Important  – Failure to install and commission this
appliance to manufacturer’s instructions may invalidate
the warranty. This note does not affect your statutory
rights.

CORGI

All CORGI registered installers carry a CORGI
identification card and have a registration number. Both
should be recorded in your boiler Log Book.

You can check your installer is registered by telephoning
+44 (0) 1256 372300 or writing to:-
CORGI. 1 Elmwood, Chineham Business Park, Crockford
Lane, Basingstoke, RG24 8WG.

Important - Installation, Commissioning, Service &
Repair

This appliance must be installed in accordance with the
manufacturer’s instructions and the regulations in force.
Read the instructions fully before installing or using the
appliance.

In GB this must be carried out by a competent person as
stated in the Gas Safety (Installation & Use) Regulations.

Definition of competence: A person who works for a
CORGI registered company and holds current certificates
in the relevant ACS modules, or valid ACoP equivalents, is
deemed competent.

In IE this must be carried out by a competent person as
stated in I.S. 813. "Domestic Gas Installations".

This appliance must be earthed. Connection shall be 
made to a 230 V ~ 50 Hz supply. The appliance must 
be protected by a 3 amp fuse.

Do not interfere with any sealed components on this 
appliance

The appliance must not be operated without the casing
correctly fitted. It is important that the inner casing 
panels are not removed for any reason other than for 
servicing by a qualified service engineer.

Regular skilled servicing is required to maintain the safe
and efficient operation of your boiler throughout its 
working life. Further information on this subject is given
at a later stage.

If it is known or suspected that a fault exists on the a
ppliance, it must not be used until the fault has been 
corrected by a competent person. If a gas leak is 
suspected turn off the appliance and consult your local 
gas supplier or service engineer.

Flammable materials must not be stored in close 
proximity to the boiler.

Do not obstruct any purpose provided ventilation 
openings.

The minimum clearances must be observed at all times 
for safety and servicing.

Front

- 450 mm (unless behind openable door).

Top

- 200 mm twin pipe vertical flue/250 mm concentric

flue though 400 mm is recommended for both instances.

Do not hang items on the boiler to dry. If a storage 
shelf is fitted it should be at least 75 mm above the top 
of the case and 

removable

.

Any warning labels on the appliance must be adhered 
to.

The programmer has a replaceable battery (to provide 
memory for the programmer set and default times). The 
battery must be disposed of in a safe manner.

About the Guarantee

Information about your guarantee is detailed separately.
Please note that it only covers the boiler and 

not your 

pipework, radiators, valves, etc.

If you call a Potterton 

service engineer out during the guarantee period to 
anything other than an actual boiler fault- you will be 
charged for the visit and any work carried out.

About the Boiler

This is a Floor Mounted, Fan Assisted Balanced Flue 
Gas Boiler. This boiler is for use with Natural Gas (G20) 
only at 20 mbar and for use in GB/IE only.

The information given in these instructions will help you 
obtain the maximum comfort from your boiler with the 
minimum trouble and cost.

Please take time to read 

through these instructions as they will help you 
understand how to get the best use out of the boiler.

Powermax HE is a condensing combination boiler in 
which the gas burner heats the contents of the built-in 
hot water store to provide domestic hot water. A pre-
mixed burner is used to ensure that the gas is burned 
cleanly and efficiently.

To reduce running costs, timed operation of the central 
heating is essential and a Powermax programmer is 
built-in to provide this function. It enables both hot water
and heating periods to be timed for both comfort and 
economy. Your installer may have fitted another make 
of programmer remote from the boiler and should have 
provided you with instructions on its use.

Summary of Contents for Powermax HE 85

Page 1: ...r fault lock out conditions are displayed as E number or A number see chart on Page 7 Note Please record the fault code and the boiler Serial No see page 8 when contacting the Service department Reset button Use this button to scroll display when setting the desired hot water temperature or checking status or pressure Use also to re start boiler after fault is repaired Amber neon indicates that th...

Page 2: ... later stage If it is known or suspected that a fault exists on the a ppliance it must not be used until the fault has been corrected by a competent person If a gas leak is suspected turn off the appliance and consult your local gas supplier or service engineer Flammable materials must not be stored in close proximity to the boiler Do not obstruct any purpose provided ventilation openings The mini...

Page 3: ...ler On Off switch to the O OFF position and isolate the gas supply at the boiler It may be advisable to contact your Service Engineer if you wish to do this How your boiler Works Control of the Boiler The boiler is fitted with a control panel which indicates basic functions and also contains a programmer If your installer has fitted another make of programmer remote from the boiler the programmer ...

Page 4: ...ls are allowed to come into contact with the pipe Freezing Conditions If the water temperature within the boiler drops below 5 C a sensor operates and runs the burner to keep the water from freezing This will only operate if the electricity supply to the boiler is ON If you are away during periods of cold weather we recommend leaving your boiler on and adjusting your control system e g thermostat ...

Page 5: ...described in Section 2 0 Page 6 To set up your own ON OFF times refer to Section 3 0 Page 6 If you wish to return to the built in time periods after changes have been made to them firstly ensure the programmer is in Normal Operation Section 1 0 Page 6 Then press hold down the and buttons together after 2 seconds or so release the two buttons and the built in periods will be active Using the HW and...

Page 6: ... Monday If you wish only to change the HW times press the SELECT button under the HW neon and it will start to flash Adjust using or Press STEP and OFF1 will flash Adjust using or 3 3 ON2 OFF2 ON3 OFF3 can be set by repeating the procedure shown for ON1 OFF1 3 4 Once OFF3 has been set press STEP and Tuesday will now flash 3 5 Repeat the procedure for Tuesday and all other days of the week 3 6 Once...

Page 7: ...ff boiler Call Powermax service A 19 Flame detection gas valve fault Switch off boiler Check replace gasvalve press RESET A 20 Flame detected with closed gasvalve Switch boiler off on Press RESET If repeated call Powermax service A 33 Fan speed incorrect Switch boiler off on Press RESET If repeated call Powermax service A 40 System response fault Open radiator valves if shut press RESET If repeate...

Page 8: ...6 000 454 Technical IE Tel 1850 560570 Publication No 5106228 Iss 04 02 2004 BAXI POTTERTON A Trading Division of Baxi Heating UK Ltd Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN Website www potterton co uk company Powermax SEL SEL MAINS ON POWER CH HW PROG PROG C H ADVANC E H W TEMP RESET BURNE R LOCK OUT Cylinder Serial Number label on outside of bottom plinth Heat Engine Serial Numbe...