background image

All descriptions and illustrations provided in this leaflet have been

carefully prepared but we reserve the right to make changes and

improvements in our products which may affect the accuracy of the

information contained in this leaflet. All goods are sold subject to our

standard Conditions of Sale which are available on request.

General Enquiries (GB)

Tel.

08706 060 780

Sales (GB)

Tel.

08706 060 403

Fax.

01772 695 416

Technical (GB)

Tel.

08706 060 955

Service (GB)

Tel.

08706 060 933

Fax.

08706 060 966

Literature Request (GB)

Tel.

08706 060 623

Spares (GB)

Tel.

08706 000 454

Technical (IE)

Tel.

1850 560570

Publication No.

5106228 - Iss.

04 

(02/2004)

BAXI POTTERTON

A Trading Division of Baxi Heating UK Ltd

Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN
Website www.potterton.co.uk

company

Powermax

-

+

SEL

SEL

-

+

MAIN

S ON

POW

ER

CH

HW

PRO

G

PROG

C.H. A

DVAN

CE

H.W. TE

MP

RESE

T

BUR

NER

LOCK

 OUT

 Cylinder Serial

Number label on outside
of bottom plinth

Heat Engine Serial
Number data badge
behind top front panel

When contacting Baxi Potterton please have the
following information to hand:

Appliance Name
Model Number
Serial Number

The Label (detailing serial and G.C. numbers) is
behind the top front panel. To remove: pull the
bottom edge of the top panel forward and up to
clear fixings.

The serial number labels are located as shown.

Summary of Contents for Powermax HE 85

Page 1: ...r fault lock out conditions are displayed as E number or A number see chart on Page 7 Note Please record the fault code and the boiler Serial No see page 8 when contacting the Service department Reset button Use this button to scroll display when setting the desired hot water temperature or checking status or pressure Use also to re start boiler after fault is repaired Amber neon indicates that th...

Page 2: ... later stage If it is known or suspected that a fault exists on the a ppliance it must not be used until the fault has been corrected by a competent person If a gas leak is suspected turn off the appliance and consult your local gas supplier or service engineer Flammable materials must not be stored in close proximity to the boiler Do not obstruct any purpose provided ventilation openings The mini...

Page 3: ...ler On Off switch to the O OFF position and isolate the gas supply at the boiler It may be advisable to contact your Service Engineer if you wish to do this How your boiler Works Control of the Boiler The boiler is fitted with a control panel which indicates basic functions and also contains a programmer If your installer has fitted another make of programmer remote from the boiler the programmer ...

Page 4: ...ls are allowed to come into contact with the pipe Freezing Conditions If the water temperature within the boiler drops below 5 C a sensor operates and runs the burner to keep the water from freezing This will only operate if the electricity supply to the boiler is ON If you are away during periods of cold weather we recommend leaving your boiler on and adjusting your control system e g thermostat ...

Page 5: ...described in Section 2 0 Page 6 To set up your own ON OFF times refer to Section 3 0 Page 6 If you wish to return to the built in time periods after changes have been made to them firstly ensure the programmer is in Normal Operation Section 1 0 Page 6 Then press hold down the and buttons together after 2 seconds or so release the two buttons and the built in periods will be active Using the HW and...

Page 6: ... Monday If you wish only to change the HW times press the SELECT button under the HW neon and it will start to flash Adjust using or Press STEP and OFF1 will flash Adjust using or 3 3 ON2 OFF2 ON3 OFF3 can be set by repeating the procedure shown for ON1 OFF1 3 4 Once OFF3 has been set press STEP and Tuesday will now flash 3 5 Repeat the procedure for Tuesday and all other days of the week 3 6 Once...

Page 7: ...ff boiler Call Powermax service A 19 Flame detection gas valve fault Switch off boiler Check replace gasvalve press RESET A 20 Flame detected with closed gasvalve Switch boiler off on Press RESET If repeated call Powermax service A 33 Fan speed incorrect Switch boiler off on Press RESET If repeated call Powermax service A 40 System response fault Open radiator valves if shut press RESET If repeate...

Page 8: ...6 000 454 Technical IE Tel 1850 560570 Publication No 5106228 Iss 04 02 2004 BAXI POTTERTON A Trading Division of Baxi Heating UK Ltd Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN Website www potterton co uk company Powermax SEL SEL MAINS ON POWER CH HW PROG PROG C H ADVANC E H W TEMP RESET BURNE R LOCK OUT Cylinder Serial Number label on outside of bottom plinth Heat Engine Serial Numbe...

Reviews: