FLUE TERMINAL ARRANGEMENTS
Clips every
1000 mm
2.12 ROOM SEALED FLUE (TYPE C
XY
)
There are three approved room sealed arrangements where both the air inlet and
fl
ue discharge terminate
outside the building.
T
YPE
C
13
& C
33
F
LUE
AND
AIR
DUCTS
TERMINATE
EITHER
HORIZONTALLY
OR
VERTICALLY
IN
THE
SAME
POSITION
Flue and air ducts are supplied to a concentric design (130/200mm). See Fig 3.5 for component choices.
Flues should slope back to the Heater by 3 degrees.
Terminal positions must comply with the requirements detailed in section 2.12
V
ENTILATION
R
EQUIREMENTS
(T
YPE
C
13,
C
33
& C
53
)
Where the appliance is installed in a
ROOM
or
COMPARTMENT
no additional ventilation is required.