PostProcess Technologies, Inc. • www.postprocess.com • REV C | page 8
1. OPERATION
1.3.3 Setting the Ultrasonics Time
1.3.4 Setting the Ultrasonics Power
Pressing the
Fn
Button twice accesses the
Time Settings
for ultrasonics. If you want the ultrasonics to run constantly
throughout the cycle, press the
UP
arrow and a small “
infinity
”
icon will be displayed as shown left.
The CENTI has two levels of ultrasonic power:
High
or
Low.
To set the ultrasonics power level, press the
Fn
button three times or until the
Sonics
icon is flashing. Press the
UP
arrow to set ultrasonics for
High
power and
press the
DOWN
arrow for
Low
power.
Depiction of the
Full
ultrasonic power setting.
Depiction of the
Low
ultrasonic power setting.
To set up the ultrasonics to run for a specified period of time,
press the
DOWN
arrow and select a run time in minutes from
1 to 99.
To increase or decrease the time quickly, press and hold the
up or down arrow. The time values are circular, pressing the
down arrow from 1 will take the value to 99 and pressing the
up arrow from 99 takes the value to 1.
While the time is being set the clock and the numerals will
be flashing. The
Ultrasonics
icon will be displayed to indicate
that ultrasonics are the function being set.