G-2108/G-3106 User’s Manual Chapter 3: Operations and Settings
21
3.1.3
Advanced Functions
Media Calibration
When the printer is on standby, press and hold the [FEED/Calibration] button (hold for around 4
seconds), the printer will automatically feed labels and the media calibration is done. During this
process, all three indicators will start blinking. When all three indicators stop blinking and return to
a steady state, the media calibration is complete.
•
When it is the first time installing the media or when changing to a different type of media,
media calibration must be performed.
•
No calibration is needed when using continuous media.
Obtaining Printer Configuration Information
When the printer is on standby, press and hold the [PAUSE/Self Test] button (hold for around 4
seconds), all three indicators will blink once and then return to a steady state, the printer will print a
self-test page with detailed information regarding the printer’s configuration then return to standby.
The information includes: The printer’s model, firmware version, hardware’s parameters and its
current status, thermal transfer/direct thermal mode, font list, etc.
Reset to Factory Setting
When the printer is on standby, press and hold the [CANCEL/
Reset] button (hold for around 4
seconds), all three indicators will start blinking (if no further input is detected for the next 8 seconds
then the printer will return to standby). Release the [CANCEL/
Reset] button and press it again to
initiate the reset process, the [READY] indicator would be off and the rest two indicators would
blink simultaneously, when all three indicators are lit and return to a steady state, the reset process
is complete.
The number of printed labels (pcs) and printed length (m) cannot be restored to factory default
value.