background image

4

2  Begin pole assembly

Locate the two screws loosely 
pre-installed at the pole joint. 
Using the appropriate hex 
wrench, remove them and set 
them aside. Leave the other two 
screws in place.

3  Assemble pole

Taking care not to strain the 
cables, lay the pole out on the 
floor (preferably on a rug or 
similar soft surface). Insert the 
lower half of the pole into the 
upper half.

4 Connect pole halves

Make sure that the poles are 
aligned correctly aligned,  
using the notch and pin as a 
guide. Reinsert and tighten 
the bolts you removed in the 
previous step.

Summary of Contents for QubeVu DimStation

Page 1: ...QubeVuQuickStart DimStationassembly andsetup...

Page 2: ...2 WelcometoQubeVuDimStation theInstantDimensionInvention Thisguidewillassistyouin assemblingandsettingup yournewDimStation 15 minutes...

Page 3: ...3 DimStationQuickstart Display Head Calibration box Ethernet cable Base Hex wrenches Power cord Pole 1 Inventory Carefullyunpackand familiarizeyourselfwith everythinginthebox...

Page 4: ...vetheothertwo screwsinplace 3 Assemblepole Takingcarenottostrainthe cables laythepoleoutonthe floor preferablyonarugor similarsoftsurface Insertthe lowerhalfofthepoleintothe upperhalf 4 Connectpolehal...

Page 5: ...armsofachairforthisstep Removethefourboltsthatare pre installedintheblockatthe bottomofthepole 6 Attachbase Withthepowerblockhanging offtheedgeofthetable insert thetwopinsinthebaseintothe matchinghol...

Page 6: ...6 Display cable Base Power block Cable shroud 7 Completepole Standthecomplete assembled poleupright Tomaketherestofthe assemblyprocessassimpleas possible reviewthenamesof theDimStation spartsatleft...

Page 7: ...Loosenthefourboltsthat securethetopofthecable shroud Donotremovethem Slidetheshroudcoverbackand liftitoff Setitaside 9 Beginattachmentofhead Aligntheheadwiththecable shroudatthetopofthepole Itmayhelpt...

Page 8: ...eportsonthebackofthe headarealsolabeled 12 Attachcables Usethisguidetocorrectly connectcablestotheirports in thelistedorder Order Cable label Port label 1 Ethernet Ethernet 2 USB 3 USB 3 3 USB 2 USB 2...

Page 9: ...theshroud 14 Reattachshroudcover Putthetopbackontheshroud cover Slideitforwarduntilit clicksintoplace thenre tighten thefoursscrewsthatsecureit 13 Alignthehead Gentlyfoldingthecablesinto thecableshrou...

Page 10: ...he bottomcorneronthebackof thedisplay Youwon tneedthisagain 18 Choosedisplaylocation Thedisplayisusuallymounted justabovethedisplaycable opening It spossibletomountthe displayupto6inchesaboveor belowt...

Page 11: ...displaytothepole atyourchosenlocationby re tighteningtheboltonthe U shapedbracket 20 Connectthedisplaycable Attachthedisplaycabletothe mini USBportlocatedwhere youremovedthecablecoverin apreviousstep...

Page 12: ...DimStation sbase Centerit fromsidetoside Tolocateyourscalefront to back findthesmallgroove engravedonbothedgesof thebase Usethisasthe front to backcenteringpoint foryourscale 20 Attachthepowercable At...

Page 13: ...mStationQuickstart YourDimStationisnowready tobepluggedin Whenitis the softwaresetupprocesswill beginautomatically Don tpluginyourDimStation unlessyouhaveafewminutesto completeallofthesetupsteps 5 min...

Page 14: ...Touchthearrow buttontobeginsetup 2 AccepttheUserAgreement ReviewtheEndUserLicense Agreement EULA byusingthe upanddownscrollbuttonson therighthandside Touchthethumbsupbutton toconfirmyouhavereadand ac...

Page 15: ...15 DimStationQuickstart 3 Setyourtimezone Selectyourtimezone and thentouchthecheckmarkto continue 4 Adjustthedateandtime Adjustthedateandtimeif necessary andthentouchthe checkmarktocontinue...

Page 16: ...even Ifyourbaseisasmooth topped scaleortheDimStationbase touchtheleftbutton Ifyourbaseisascalewithan unevensurface suchasrollers touchtherightbutton 6 ZeroHeight Unevensurface Ifyouhaveasmooth topped...

Page 17: ...kstart 7 ZeroHeightcontinued Itisimportanttokeep DimStation sbaseclearand unobstructedduringzero heightcalibration sothatitcan setZeroHeightaccurately 8 ZeroHeightcontinued Pleasestandclearbeforethe c...

Page 18: ...kmarkto continue 10 SettheScanZone TheScanZoneistheareain whichDimStationlooksfor anddimensionsitems For bestperformance adjustthis tocoverthelargestarea possiblethatcanbeusedfor scanningitemsandkeptc...

Page 19: ...tobegin usingyourQubeVuDimStation 12 Confirmcalibration TestwhetheryourDimStation isproperlycalibratedbyplacing thecalibrationobjectonthe baseorscaleandcheckingthe displayeddimensions Dimensionsshould...

Page 20: ...erremoveQubeVu shead cover ortheelectricalconnection panelsatthebaseofthepole assembly Nevermodifyorattemptto repairyourunit Servicemust beperformedonlybyPostea personnel Handlecablesandcable connecto...

Page 21: ...omanyavailable DHCPserver However italsohasafixed fail safeIPaddressof169 254 1 1 IfyourprefertouseDHCP your networkadministratorcanadviseyouastotheIPaddressleasedbyQubeVu Configure PC network setting...

Page 22: ...anotherinnovationby 222ThirdStreet Cambridge MA02142USA www postea com 2015PosteaInc Allrightsreserved QubeVuandDimStationareregisteredtrademarksofPostea...