I-Class
69
Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
14
a) Place the media in the
sensor. Record the
reading and label it “P”
(paper).
b) Place the backing, notch,
or mark in the sensor.
Record the reading and
label it “G” or “M” (Gap or
Mark).
c) Remove media. Record
the reading and label it
“E” (Empty).
GAIN TRAN <yyy>
*08 <0 - 31>
Or, for reflective media:
GAIN REFL <yyy>
*08 <0 - 31>
The samplings using the
selected Gain Number
are taken.
15
Press the
Key, and
then press the
Key.
ADVANCED ENTRY
SENSOR LEVELS
The sensor readings
must be entered into the
printer.
16
Press the
Key.
Using the
Key or the
Key, set the Paper
Sensor Level to the value
determined in the previous
step.
Press the
Key to
select the entry and
advance the menu.
Repeat for the Gap Sensor
Level (or Mark Sensor Level)
and the Empty Sensor Level
entries.
PAPER SENSOR LEVEL
P*198 G*084 E*014
GAP SENSOR LEVEL
P*198 G*084 E*014
EMPTY SENSOR LEVEL
P*198 G*084 E*014
Or, for reflective media:
PAPER SENSOR LEVEL
P*015 M*181 E*213
MARK SENSOR LEVEL
P*015 M*181 E*213
EMPTY SENSOR LEVEL
P*015 M*181 E*213
Selection is denoted by
an asterisk (*).
The displayed message
will change and the
selection will flash to
indicate the next entry.