BRX Power Injector Installation Guide
26
180-0192-001-R01
SYMPTOM #2: A BRX-PWR-M module is not functioning
. This is indicated by the Power LED
(D900) on the BRX-PWR-M off.
Case #5: No power to the BRX-XLR-
M module
The Power Status LED (D900) on the
BRX-PWR-M is off. Verify that the
BRX-PWR-M is installed properly and
secured with the four (4) installation
screws. If this is the case, go to
Symptom #1 above and make sure
the power cabling to the BRX Power
Injector is properly installed and that
the local (-48Vdc or 112-220VAc )
power source is activated. If using
RFT-V, make sure there is current on
the Express Power pairs.
SYMPTOM #3: The status LED of a BRX Power Pair is OFF when it should be ON
Case #1:
The pair is not properly
inserted in the punch-down connector.
Make sure the pair in pushed all the
way into the punch-down block to
make a solid contact with the BRX-
PWR-M module pair.
Case #2:
the pair is not punched in
the right
POWER OUT
row. Do not
punch-down
blocks
under
the
POTS/DSL
header, this is reserved
for a potential future enhancement.