BRX Power Injector Installation Guide
18
180-0192-001-R01
Step 3:
select the POTS pairs from the second
(2
nd
) cable binder and secure them in the left
bank (
BYPASS-IN)
of punch-down blocks.
NOTE:
These POTS pairs are duplicated into
the corresponding punch-down block in the right
bank (
BYPASS-OUT
).
Step 4:
you are now ready to attach the pairs of
the cable binder connecting to the DSLAM that
shall carry the POTS signal.
Step 5:
Use the row of punch-down blocks
labeled as Power Out to connect the pairs of
each cable binder that require the -48Vdc power
to feed BRX devices on otherwise dry pairs.
You are now ready to connect the binder cables
of the rightmost opening to the nearby DSLAM.
NOTE:
use the provide Tie-Wrap to secure the
BRX Power pairs inside the BRX Power Injector
enclosure.
Table 6: Using the POTS Bypass section of the BRX Power Injector
3.4 Installing Copper Cables into BRX Power Injector
Now that the power source is connected to the BRX Power Injector, you can connect the BRX Power
pairs to the cable binder(s) that then connect to the POTS connector of the DSLAM. This procedure
is the same, whether there is a nearby cross-connect or not.