background image

 

 

Page 17 

required drivers  will be available on our web: http://www.posiflex.com. Then 
follow instructions from your system integrator for software recovery. 

Operating System Installation 

 

This  product  is  highly  professionalized  equipment.  The  installation  of  an  OS 
into  a  machine  without  any  preloaded  OS  could  be  a  major  difficulty  for 
average  user  or  obstacle  by  possibly  unintentional  negligence  even  for  PC 
veterans  to  accomplish  such  a  task.  Therefore,  OS  installation  into  a  system 
without  preloaded  OS  is  highly  discouraged.  Posiflex  Technology,  Inc.  shall 
not be responsible for any technical support to questions on this aspect. 

 

APPLICATION ENVIRONMENT 

 

It is 

very

 important that you check the following operational guidelines: 

 

Ventilation 

 

This  terminal  must 

NOT

  be  operated  in  an  environment  with  restricted 

ventilation. There must be at least 25 mm air clearance around any top or side 
ventilation  holes  with a free flow of air around the  unit at 

ALL

 times for the 

installation. 
 

Operating Environment 

 
The equipment must not be operated or stored in extremes of both temperature 
and  humidity/moisture.  (Operating  range  0°C  to  40°C  and  up  to  80% 
humidity – none condensing, max. wet bulb 26

°

C) 

 

UPS Battery (option) 

General care: 

 

The  UPS  battery  is  consumables  beyond  product  warranty.  Please  definitely 
observe  the  alerts  in  beginning  of  this  manual.  Please  always 

disconnect

  the 

battery if the system is to be powered off for more than few days. Reconnect it 
and turn on the system to recharge the battery for 1 ~ 2 hours every 3 months / 
every month for temperature lower than / over 30

°

C. Temperature above 

40°C 

must  be  strictly  avoided

  as  it  could  cause  termination  of  battery  life  and 

Summary of Contents for XP-3000 Series

Page 1: ...fits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory...

Page 2: ...the busiest situation XP 3000 3300 Series applies Intel Pine View CPU technology fast speed Ethernet as well as plenty of connects ports of USB Serial VGA and CR ports It also integrated with thermal...

Page 3: ...Page 2 INTRODUCTION PRODUCT PICTURES Front Views Side Views Rear Bottom Views 1 2 3 4 5 6 7 8 9 10 11 14 15 16 17 9 12 13...

Page 4: ...Exit 14 Bottom plate compression lock 15 Bottom plate tenon 16 Rubber foot with bottom plate fixing screw 17 Bottom plate PRODUCT FEATURES Standard Features Models Item XP 3012H XP 3015H XP 3312H XP 3...

Page 5: ...imum Paper roller diameter 80mm Paper thickness Less then 86 m LCD panel tilt angle 14 55 degree Table Summary of features Models Item XP 3012E XP 3015E XP 3312E XP 3315E LCD Display TFT LCD Panel Dig...

Page 6: ...tems Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR2 SODIMM memory expansion up to 2GB...

Page 7: ...ple push on the switch in 10 sec may turn off the power Note There must always be at least 10 seconds waiting before switching on again once the system is powered off successfully Brightness Control I...

Page 8: ...video memory size is default in 128 MB and can be set to be 64 MB VGA Port The VGA port in the XP 3000 3300 system supports either a rear mount 2nd display or a separately connected LCD monitor or tou...

Page 9: ...mouse at the point when the touch panel is touched If the point touched is dragged across the screen surface it works as the mouse drag and drop feature If the point is touched released and touched wi...

Page 10: ...e that the push lock button in the lock release lever When the LCD panel needs to be push or pull from the most rear end please press the push lock and the lock release lever at same time then the LCD...

Page 11: ...in order to reduce the paper loss adjustable function please see following chapter Printer setup The printer will leave the advance paper in 4 8 mm long for each print It is highly suggested to print...

Page 12: ...ard s movement can be two way of the slot the reading process should be passing through whole slot horizontally A non standard card recorded without complete degaussing prior to recovery may accept on...

Page 13: ...e at right Next please unfasten these two screws which fasten the UPS bracket and take out the bracket as shown in the lower left picture Please take it out and place it in the battery compartment at...

Page 14: ...and pull up the terminal carefully than you will see the I O plate I O Plate View A 2x Serial Port RS 232 COM1 2 B 1x Serial Port RJ 45 COM3 C 1x LAN Port D 4x USB Ports E 1x CR Ports F 1x VGA Port D...

Page 15: ...connector be screwed into place once seated Please make sure that each connector has to be connected to the right device in the right way CAUTION On doing any insertion or extraction of any connector...

Page 16: ...t customer display kits for XP 3000 3300 series Counter space saving design with 2 20 VFD PD 2606 and 2 20 LCD PD 330 provides the clearest view for customers In addition real base mount graphic STN L...

Page 17: ...he CR port in XP system This cable has a 6 pole plug at one end and an 8 pole plug at the other The 8 pole plug should be inserted into the connector marked signal cable from POS Printer at the rear o...

Page 18: ...on This terminal must NOT be operated in an environment with restricted ventilation There must be at least 25 mm air clearance around any top or side ventilation holes with a free flow of air around t...

Page 19: ...iately A larger external battery may be connected to give an extended operation Please check your dealer about this capability when required WARNING If there are any signs of over charging or leakage...

Page 20: ...in system jumper setting and printer parameter setting However such support is limited to the application of specific Posiflex peripherals and must be disabled when the Posiflex peripherals are disco...

Reviews: