Part 10
The following table depicts the usage of all the ports under service window.
However, it is highly recommended only the trained or certified technician
should configure the DIP switch, for incorrect configurations might cause
unexpected results or even damage the terminal.
Label
Description
LPT
Connects to the parallel device via a conversion cable.
SATA1
Connects to eternal SATA HDD.
PWR1
Connects to external SATA HDD for supplying power.
DIP Switch
Description
1 On
2 Off
Default
1 Off
2 On
Clear CMOS
Off
Linux or WinCE
3
On
Windows OS (Default)
Off
Fujitsu Touch Panel
4
On
ELO Touch Panel or ABON Touch Panel
Off
Windows/Linux/Win CE (Default)
5
On
MS-DOS
Off
Enable On Board USB Touch
6
On
Disable On Board USB Touch
Off
Reserved
7
On
Reserved
8
Off
Reserved
SIDE MOUNT UPGRADE KIT (OPTION)
Remove the 2 screws circled in the left
picture to remove the cover for side
mount upgrade kit. Take out the cable
inside this cover and connect it to the
white connector inside the side mount
upgrade kit like SD-500 series as
arrowed in the right picture. Gently
arrange the excessive length of this cable
back in the hole and screw-fit it back to
the position originally occupied by the cover. Please
reserve the cover if there is chance to have the side mount kit removed in the
future.