background image

 

 

Part 10 

The  following  table  depicts  the  usage  of  all  the  ports  under  service  window. 
However,  it  is  highly  recommended  only  the  trained  or  certified  technician 
should  configure  the  DIP  switch,  for  incorrect  configurations  might  cause 
unexpected results or even damage the terminal. 

Label 

Description 

LPT 

Connects to the parallel device via a conversion cable. 

SATA1 

Connects to eternal SATA HDD. 

PWR1 

Connects to external SATA HDD for supplying power. 

 

DIP Switch 

Description 

1 On 

2 Off 

Default 

1 Off 

2 On 

Clear CMOS 

Off 

Linux or WinCE 

On 

Windows OS (Default) 

Off 

Fujitsu Touch Panel 

On 

ELO Touch Panel or ABON Touch Panel 

Off 

Windows/Linux/Win CE (Default) 

On 

MS-DOS 

Off 

Enable On Board USB Touch  

On 

Disable On Board USB Touch 

Off 

Reserved 

On 

Reserved 

Off 

Reserved 

 

SIDE MOUNT UPGRADE KIT (OPTION) 

Remove  the  2  screws  circled  in  the  left 
picture  to  remove  the  cover  for  side 
mount  upgrade  kit.  Take  out  the  cable 
inside  this  cover  and  connect  it  to  the 
white  connector  inside  the  side  mount 
upgrade  kit  like  SD-500  series  as 
arrowed  in  the  right  picture.  Gently 
arrange the excessive length of this cable 
back in the hole and screw-fit it back to 

the  position  originally  occupied  by  the  cover.  Please 
reserve the cover if there is chance to have the side mount kit removed in the 
future. 
 

Summary of Contents for KS - 7212/X

Page 1: ...ta or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential...

Page 2: ...batteries and always replace only with battery of same type DAILY MAINTENANCE GUIDE For regular cleaning of the KS systems please use only soft haired brush or dry soft cloth You may use moist soft cloth to remove stains when necessary Apply only proper amount of mild neutral detergent for obstinate stains Please note that never use Acryl dissolving solvent or Polycarbonate dissolving solvent You ...

Page 3: ...Part 3 INTRODUCTION PRODUCT PICTURES Front View Rear View Side Views Bottom View Inside Base 7 4 6 1 5 3 7 8 2 1 9 20 16 22 17 21 18 7 12 19 13 13 5 11 10 14 18 15 ...

Page 4: ...unt pole display kit 18 Cable tie in the terminal s back cover for desktop use only 19 Cable tie in the I O plate for wall mount use only 20 Oval cable passage on cast base trunk 21 Cable tie for all cables 22 Screw posts for optional HDD in base I O Panel Call out Label Description A CR Controlling up to 2 cash drawers B LINE OUT Audio Output C LAN2 LAN port connecting to Ethernet D USB0 3 4 USB ...

Page 5: ...5 wire resistive with USB interface k k k k Durable resistive type touch panel that endures 35 million touches min at same spot l l l l Supports various I O ports 1 4 x COM ports DB9 x 2 RJ45 x 2 supporting 5V DC output 2 6 x USB ports 4 on rear panel 2 on left side 3 2 x Ethernet LAN port supporting 10 100 1000 Base T 4 1 x CR port controlling up to two cash drawers 5 1 x lineout for audio output...

Page 6: ...trol m LPT interface conversion cable n Wall mount kit INSTALLATION GUIDES CAUTION Before any installation or cable connection to the set please always make certain that the system is turned off and the external power source to the set is removed to prevent electric hazard Never touch any metal pin in the connectors or circuits to avoid high voltage hazard or electrostatic discharge damage unless ...

Page 7: ...ng out the connector such as the LAN port or the CR port or the alternate RJ45 form COM3 4 port Please also note that the fixing screws have to be loosened free prior to disconnection such as the 2 regular DB9 form COM ports or the VGA port Please always hold the connector head instead of pulling on the cable wire when disconnecting any connector Failure to do this could damage the cable and jack ...

Page 8: ...er rear corner of base bottom Refer to the pictures at right Use the 3 attached screws to fix the metal base plate of the PD to bottom plate of mini slim base at the circled positions the holes marked with KS on bottom plate of PD against the holes marked P on bottom plate of KS system Connect the interface cable to go into the base through cable exit arrowed at right to the main unit Rear Top Mou...

Page 9: ...hed 4 pcs long screws to fasten this bracket to the main unit back cover which circled in the right picture Then hold the LCD monitor with bracket and aim to join bracket which just fixed on the main unit and fasten these 3 pcs short screws which circled in the right picture to attach LCD monitor to the terminal PREPARING THE MAIN UNIT The service window locating at the back of the main unit just ...

Page 10: ... OS Default Off Fujitsu Touch Panel 4 On ELO Touch Panel or ABON Touch Panel Off Windows Linux Win CE Default 5 On MS DOS Off Enable On Board USB Touch 6 On Disable On Board USB Touch Off Reserved 7 On Reserved 8 Off Reserved SIDE MOUNT UPGRADE KIT OPTION Remove the 2 screws circled in the left picture to remove the cover for side mount upgrade kit Take out the cable inside this cover and connect ...

Page 11: ...ould be inserted into the connector marked signal cable from POS Printer at the rear of one of the cash drawers CONNECTING CABLES To have the re assembled main unit with stand assembly ready for operation please connect all required cables to the appropriate connectors Please make sure that each connector is connected to the correct port with the correct orientation Damages due to incorrect connec...

Page 12: ...der drivers in OS recovered HDD and the latest versions of these required drivers will be available on our web http www posiflex com tw Then follow instructions from your system integrator for software recovery OPERATING SYSTEM INSTALLATION The installation of an OS into a machine without any preloaded OS could constitute major difficulty for average user or obstacle by possibly unintentional negl...

Page 13: ...orange when external power is ready and turns to blue when system power is turned ON Hardware Power Switch The power switch located at left side of the main unit is a tactile pushbutton switch This switch controls the power on off of the system After external power is preset this switch turns the system on when pushed only This switch turns the system off when pushed again during power on status H...

Page 14: ...p monitoring for the preset conditions and turn on the system when the preset conditions are met Please note that if the terminal is improperly turned off before a complete boot up procedure the above preset power on control functions will be disabled until next turning off after a complete boot up BRIGHTNESS CONTROL At left side of the main unit below the power switch there are brightness adjust ...

Page 15: ...setup or jumper settings COM1 2 ports are standard RS232 serial ports as status at delivery COM3 4 is also set to standard RS232 serial port as status at delivery if the option conversion cable is applied PARALLEL PORT For this terminal the parallel port is optional for order and must be coupled with an optional conversion cable It should be connected to the special connector inside the service wi...

Page 16: ...ffect like clicking on the right button of a mouse touching any point on the screen surface after touching the right click sticky button results as a click on the right button of the mouse at that point Touch Manager Touch Terminal Manager for each type of touchscreen is available for user to set up touchscreen functions If your system is preloaded with the OS of your choice the chances are the Ma...

Reviews: