Part 13 

well-maintained battery can be expected to provide adequate service for 1 year. 

Battery replacement: 

In the power management circuit in this POS system, there is a handy 

battery monitor feature to help user find out when an UPS battery should be 
replaced. The battery monitor will always first measure and check the UPS 
battery to see if the UPS battery is already incapable of service or if there is 
any sign for the possible critical fault development in the battery before it 
allows the charging operation to the UPS battery. Reason for such extra check 
is that indifferent recharging on a battery with some critical fault like micro 
short circuit will not only boost the fault development in and total failure of the 
battery but also can result in confusing system malfunction. 

In the preloaded OS, there is a built in utility Power Manager that will 

interface the UPS battery monitor status with user. When a healthy UPS 
battery is added to an originally UPS function disabled system, the Power 
Manager will enable the UPS function automatically. However, when battery 
monitor disables the battery charging as designed while the UPS function of 
the system is originally enabled, in other words the UPS battery is found out of 
order if actually installed, there will be a popup message asking the user to 
agree disabling the UPS function. The system will operate under deactivated 
UPS function no matter agreed or not. However, the monitoring goes on and 
the popup message will come back on next system power up boot if not agreed. 
In any case, please replace the used up UPS battery at power off if the battery 
is well connected there but found inoperable by such messages. 

Power Supply 

The operating voltage range of the power adaptor should cover the 

local power supply for proper operation. The power cable, the power outlet 
and any power fusing arrangements must conform to local safety regulations. 

Please 

never do any connection / disconnection

 when system is still 

powered on. 

Please always keep the external power adaptor in a free air 

circulation.

 

POWER ON/OFF 

There must always be at least 10 seconds waiting before switching on 

again once the system is powered off successfully. 

LED Indicator 

 

 

There is an LED in the logo area or under the printed logo and serves 

for several purposes. The relationship between LED status and other 

Summary of Contents for Jiva LT-5700G

Page 1: ...mitation loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties express implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only ess...

Page 2: ... 2 mouse port 3 4 serial ports with capability for 5V DC support reduce to 3 ports if RS232 interface touch panel is used 4 one parallel port 5 2 USB ports 6 one LAN port 10 100 base T Ethernet 7 one external VGA monitor port 8 one Compact Flash memory card connector for Jiva TP LT 5700G only 9 one DC 12 V power input connector 10 one UPS battery connector 11 one CR port for control over 2 cash dr...

Page 3: ...ader and finger print sensor Common security device upgrade SD100 covering option s from USB interface MSR or smart card reader and finger print sensor or iButton reader 2 in 1 security device upgrade SD200 covering options of USB interface MSR or optical scan type finger reader Bar code card reader BC 100U d Integrated rear top mount LCD customer display PD 302 e 2 in 1 cash drawer control cable ...

Page 4: ... release lever on the base backward to adjust the stand to the most horizontal position for ease of operation Insert the tip of the latchkey into a latch hole on one side near bottom of the main unit Turn this key counterclockwise to the end Do the same on the opposite side Be sure to take the key out of the hole before doing next operation Then push the lock release lever on the base backward to ...

Page 5: ...res A serial mouse is one example of a device that does not support handshaking Adjust the slack of each cable and close the cable cover Use the same plastic latchkey that is used when removing the cable cover but be sure to turn it in the clockwise direction to lock the cover in place Re adjust the tilt angle of the screen for best viewing SEPARATING MAIN UNIT In order to settle the touch termina...

Page 6: ...quirement for UPS battery in next chapter USING THE TOUCH POS CASH DRAWER The Jiva series is able to control the printer direct drive type Posiflex cash drawers Among them it is recommended that the Posiflex CR 4000 or CR 4210 be used since the terminal has been designed to compliment this cash drawer both mechanically and electrically The Jiva series will directly control the cash drawer using th...

Page 7: ...rrange all cables to come out of the area for mounting main unit from the bottom edge for ease of later operation PREPARING THE MAIN UNIT On the back of the main unit there are 4 matching pegs and a service window Push open the service window in the direction as indicated in the picture one can find a button cell battery socket two 1 x 2 JP6 9 and two 1 x 3 headers JP11 16 with 1 jumper each and t...

Page 8: ...f the Dongle and also 2 hooks on either top corner on rear side of main unit of the Jiva system Match the hooks to mount the Dongle to either corner of the Jiva system Should there be more than 2 Dongles to be installed in the application for the advantage of several fixed predetermined connections without need for connection alteration in process the third Dongle and afterwards have to attach to ...

Page 9: ...e lifting the main unit CONNECTING CABLES Connect the cables required to the appropriate connectors Please make sure that each connector has to be connected to the right port in the right orientation Some connectors have to be inserted till a click is heard such as the LAN connector It is recommended to screw on the connector once it is inserted such as the external VGA connector the LPT port conn...

Page 10: ... However please take also the main unit into consideration If the main unit is tilted to near vertical position the total height is 360 mm When the main unit is tilted to near horizontal position the total height required is 275 mm OPERATING SYSTEM RECOVERY For Jiva TP LT 5700G if not using a remote boot operating system the operating system exists in the Compact Flash Card Therefore once the Comp...

Page 11: ...http www posiflex com tw Now please follow instructions from your system integrator for software recovery Please refer to the System Protection section in chapter USING THE TOUCH POS for guidance on the Time Machine like system recovery OPERATING SYSTEM INSTALLATION This product is a highly professionalized equipment The installation of an OS into a machine without any preloaded OS could constitut...

Page 12: ...or 1 2 hours every month if the temperature exceeds 30 C When an UPS battery is installed in this equipment the environment should keep below 30 C to protect the life of the battery Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smo...

Page 13: ... battery monitor disables the battery charging as designed while the UPS function of the system is originally enabled in other words the UPS battery is found out of order if actually installed there will be a popup message asking the user to agree disabling the UPS function The system will operate under deactivated UPS function no matter agreed or not However the monitoring goes on and the popup m...

Page 14: ...t some hardware registers may be confused causing trouble for system restart or even this forced power off please disconnect the UPS battery if installed and the AC power supply for few minutes This may allow all hardware registers to reset This switch can also be programmed as an ON only switch That means if the application program issues a command compliant with the Jiva series technical manual ...

Page 15: ...tup 2 Select Power Management Setup and enter PM Wake Up Events Go to item Ring Power Up Control and change the setting to Enabled then press F10 key to save and exit CMOS setup 3 Connect a RS232 MODEM to any of COM2 COM3 or COM4 and to a proper telephone line This system may then be powered off and will automatically boot up at the MODEM ringing By LAN Wakeup For LAN wakeup an operating caller sy...

Page 16: ...e is a function built in for system protection A screen as below will pop up for a short period of time in operation system booting up stage In normal application nothing has to be done and the system boot up continues However this system protection function is provided for our end users to fight against enormous virus attacks or malicious system invasions nowadays or even some possible system cra...

Page 17: ...y this action Pressing F2 key will have no response if your system integrator did not do the protection or if you have erased their effort by action in next paragraph Pressing the three key combination of Ctrl Alt F1 will restore your system right back to the pure OS status Please never take this action unless you know exactly what you are doing and what to do next The whole process may take quite...

Page 18: ...s exactly like a standard mouse However if the system is running under safe mode due to a previous improper shutdown or for any other reason most drivers are disabled in this mode and the touch panel calibration may not coincide with the mouse pointer It is recommended that a standard USB mouse or keyboard be used in this mode All the below mentioned mouse emulation functions can be manipulated th...

Page 19: ...e controller The Posiflex Touch Terminal Manager above should be disregarded In these models the COM4 position of the system will be covered in the connection area Removal of this cover will void the product warranty Once the RS232 touch controller driver is installed the user can utilize it to calibrate the touch screen define mouse button emulation modes enable right button emulation or define t...

Reviews: