background image

Setting the splitting distance (stroke)

1

2

1

Clamping unit

2

Shut-off rod

 

The splitting stroke can be adjusted for shorter lengths of timber with the aid of a shut-off

rod:

▪ Fully retract the splitting blade.
▪ Turn off the machine.

– See:Switching off the machine [➙ 18]

▪ Press the clamping unit and move it to the desired shut-off position.
▪ Then allow the clamping unit to engage in the recess in the shut-off rod.

The splitting stroke is defined using the following lengths:

Position

Log length

1st position

20 cm

2nd position

25 cm

3rd position

33 cm

Shut-off rod removed

10 - 55 cm

5.2

Operation

 

17

Summary of Contents for M6140

Page 1: ...Operating Instructions Log splitter 8 D1010394 Edition 1001 D1010394 1001 English Copyright by Posch Gesellschaft m b H Made in Austria...

Page 2: ...his in before starting Then you can be sure that this document relates to your machine so if you have any queries you will be given the correct information Machine number Serial number POSCH Austria 8...

Page 3: ...per use 9 2 7 Incorrect use 9 3 General 10 3 1 Scope 10 3 2 Description 10 3 3 The most important components of the machine 11 3 4 Labels and their meanings 12 3 5 Set up 13 4 Start up 14 4 1 Driven b...

Page 4: ...Cleaning 24 10 Additional equipment 25 10 1 Cross type splitter 25 10 2 Special knife with rollers 25 10 3 Timber support table large 26 10 4 Wheelset 400 26 11 Troubleshooting 27 12 Technical data 2...

Page 5: ...cts Read these operating instructions through carefully before putting the machine into operation We accept no liability for damage or disruptions caused by failure to observe the operating instructio...

Page 6: ...troubleshooting Electrician An electrician is a person who by virtue of his specialist training has knowledge of electrical systems standards and regulations and is able to identify and prevent possi...

Page 7: ...rical voltage Contact with live parts can result in immediate death Protective covers and enclosures marked with this sign may only be opened by qualified electricians after the electricity supply has...

Page 8: ...0 and disconnect the power cable Never leave the machine running unattended Switch off the machine s drive unit before carrying out any adjustments Only use original POSCH spare parts Do not modify or...

Page 9: ...maining risks Even if all safety precautions are observed and the machine is used in accordance with the instructions some risks still remain Touching of revolving parts or tools Injury caused by flyi...

Page 10: ...g splitter 8 machine is suitable solely for splitting logs with a maximum length of 10 55 cm The splitter is driven hydraulically the hydraulic system is driven by an electric motor The machine is ope...

Page 11: ...1 Table 9 Wheel 2 Splitting blade 10 Electric motor 3 Log retaining tip 11 Switch plug 4 Spring clamp 12 Ventilation screw 5 Clamping jaw 13 Transport handles 6 Two hand controller 14 Shut off rod 7 P...

Page 12: ...s switched off and the tool is at rest 3 Wear protective gloves 4 Wear safety shoes 5 Wear goggles and ear protection 6 Caution moving parts 7 Read the operating instructions before starting the machi...

Page 13: ...Set up Ensure the machine is stable before starting it Set up the machine on a level firm and clear work surface The machine must be placed directly on the ground Do not place wooden boards flat piec...

Page 14: ...nly be operated on electric circuits equipped with 30 mA FI fault current protection or a Portable Residual Current Device PRCD Work on electrical equipment must only be carried out by qualified elect...

Page 15: ...ge 400 V 50 Hz Circuit breaker 16 A tripping characteristic C For the feed a cable cross section of at least 2 5 mm must be used This cable cross section is only a minimum specification In the event o...

Page 16: ...fe between the two handles Check the nature of the log knots etc Log stands upright by itself Move the log the right position using the two handles Push both handles downwards at the same time The spl...

Page 17: ...itting blade Turn off the machine See Switching off the machine 18 Press the clamping unit and move it to the desired shut off position Then allow the clamping unit to engage in the recess in the shut...

Page 18: ...ne Before switching off the machine depressurise all hydraulic functions by placing all control levers in the neutral position Driven by electric motor Type E Move the switch to the 0 position 6 Switc...

Page 19: ...f rod is also fully retracted The machine may only be transported in the vertical position or leaning backwards For horizontal transportation the ventilation screw must be replaced by a G1 2 screw plu...

Page 20: ...s of operation Replace missing screws and nuts Hydraulic lines After the first hour of operation check that all hydraulic connections are secure and are not leaking Check that all hydraulic connection...

Page 21: ...he oil sight glass is filled the oil level is at its maximum When the oil level is in the centre of the oil sight glass the oil level is at its minimum If this is the case the hydraulic oil must be to...

Page 22: ...grease with a brush The tool guide must always be well greased Recommended lubricating greases Manufacturer Type Genol Multi purpose grease Fuchs Multi purpose grease 5028 Oil changing Old oil must b...

Page 23: ...Check the oil level and top up hydraulic oil if necessary Total filling capacity of the hydraulic system Quantity 5 litres Our hydraulic system is filled with OMV HLP M10 hydraulic oil This high quali...

Page 24: ...witched off Disconnect the machine from the mains Clean the machine regularly to ensure proper operation Only wash new machines during the first 3 months with a sponge The paint is not yet completely...

Page 25: ...he timber retaining tip downwards out of the splitting knife 3 Slide the cross type splitter over the splitting knife 4 Slide the timber retaining tip back into the splitting knife Special knife with...

Page 26: ...support table large 3 Washer 2 Coach bolt 4 Self locking hexagon nut Mounting Screw the timber support table to the frame using the coach bolts washers and self locking hexagon nuts Wheelset 400 For e...

Page 27: ...y cable Have the cable examined by a specialist Contactor or motor circuit breaker faulty Have switch checked or send it in Splitting blade does not extend Rocker jammed Check the rocker Not enough hy...

Page 28: ...x pressure bar 250 190 250 Max log length cm 55 55 55 Max log diameter cm 50 50 50 Advance speed cm s 7 4 5 5 4 Retraction speed cm s 40 6 25 9 30 9 Dimensions Width cm 60 60 60 Depth cm 90 90 90 Heig...

Page 29: ...Service POSCH product To order spare parts for your machine please contact your local dealer directly 13 Service 29...

Page 30: ...lied EN ISO 12100 1 2 General design principles EN 13857 Safety distances to prevent danger zones from being reached by the upper and lower limbs EN 349 Minimum gaps to avoid crushing of parts of the...