The torque motor drive ships from the factory completely assembled, ready to install into the batten tube.  In addition, the torque motor 
drive’s drive tube alignment is preset at the factory.  Field adjustment should not be required.  Start by referring to the installation drawing 
for the motor location (drive end).  Position the torque motor drive assembly at the drive end of the curtain batten tube with the drive tube 
grooves in alignment with the batten tube keys.  Slide the assembly into the batten tube until the limit collar of the drive assembly is near 
the end of the batten tube.  At this point, ensure the machined crown slot is engaged with the motor limit key, and the flanged end of the 
crown is against the torque motor limit collar’s flange.  See detail below.  Now, with the machined crown grooves rotated and aligned with 
the batten tube keys, insert the torque motor fully until the machined crown’s flange is tight against the end of the batten tube.  To secure 
the torque motor drive to batten tube, carefully drill two (2) 13/64” dia. holes approximately 180 degrees apart and exactly 25 5/8” from 
the end of the batten tube.  See drilling detail.  

Note: Drill through two walls only (the batten tube wall and the outer drive tube wall)!

  

Install two (2) pop rivets.  See Figure D. 

 

 

Crown Detail 

 

 

Drive Tube Drilling Detail

  

 

LIMIT SLOT

LIMIT BUTTON

MACHINED CROWN

FLANGE SEATS AGAINST

LIMIT HOUSING FLANGE

MACHINED CROWN SLOT

ALIGNS WITH LIMIT KEY

MACHINED CROWN
FLANGE

TORQUE MOTOR

LIMIT COLLAR KEY

L

C

"A"

"A"

25 5/8" (WALL GUIDE)

21 1/2" (TORQUE ARM)

END OF BATTEN TUBE TO HOLE

POP RIVET

DRILLING LOCATION

GROOVE

DRILLING LOCATION

GROOVE

POP RIVET

MOTOR

BATTEN TUBE

DRILLING LOCATION

GROOVE

POP RIVET

DRILLING LOCATION

GROOVE

POP RIVET

VIEW "A-A"

Summary of Contents for Center-Roll 2081

Page 1: ...ASIUM DIVIDER CURTAIN No 2081 Wall Guide Center Roll No 2082 Torque Arm Center Roll Single Motor Operation Typical Details INST 00316 030 2000 PORTER ATHLETIC EQUIPMENT COMPANY ALL RIGHTS RESERVED 3 1...

Page 2: ...whichever shall occur first or otherwise documented and signed by an officer of Porter Athletic Equipment Company NAME OF PROJECT NAME OF DEALER NAME OF INSTALLATION COMPANY PHONE PHONE Porter Order N...

Page 3: ...PORT TUBE ASSEMBLY 7 8 TORQUE DRIVE INSTALLATION 8 9 10 WALL GUIDE TRACK INSTALLATION 10 11 HOISTING AND ANCHORING THE CURTAIN 11 12 CORD REEL MOUNTING 12 13 TORQUE ARM BELT TIE OFF 13 CORD REEL ELECT...

Page 4: ...ly depending upon the nature of the equipment and its use When the equipment is exposed to heavy use special inspections should be made in addition to the normal maintenance program At minimum a yearl...

Page 5: ...Again the safest equipment can be damaged when used by untrained personnel It is imperative the procedures and guidelines set forth in this manual are strictly observed TOOLS REQUIRED POP RIVET GUN E...

Page 6: ...e Tube Inserted Connecting Batten Tubes at Splice Location FIGURE A 4 BATTEN TUBE INSPECTION Inspect batten tube cable slots for metal shavings that may have accumulated in the batten tube cable slot...

Page 7: ...cord slot See Figure B Continue pulling the panel completely into through the cord slot until the curtain panel edge is near the opposite end of the batten tube Refer to the installation drawing for e...

Page 8: ...the weighted end section The weighted end section must be positioned at the motor end for torque arm installations and opposite end of the motor for wall guide installations In addition the weighted...

Page 9: ...low Now with the machined crown grooves rotated and aligned with the batten tube keys insert the torque motor fully until the machined crown s flange is tight against the end of the batten tube To sec...

Page 10: ...actory completely assembled ready to install into the batten tube with the exception of the torque arm strap The strap is not routed through the spacers and not dead wrapped on the torque arm drum at...

Page 11: ...AIN Depending on anchoring conditions it may be necessary to install supplemental support hardware to existing structure prior to raising the curtain Refer to the installation drawing for details The...

Page 12: ...ditions allow the optimum mounting height for the power reel assembly is above the plane of the curtain upper support tube but not more than 32 0 above the curtain batten tube Mounting brackets and ha...

Page 13: ...the outer flange of the assembly with the cord wound on the drum rotate the reel and cord together no more than two 2 revolutions in a clockwise direction Now without releasing the tension pull the r...

Page 14: ...d position See Figure H Refer to the specific counter torque style for the operational test procedure Caution Until the torque motor limits are set caution must be exercised when operating the curtain...

Page 15: ...omplished by performing the following test Remove the limit switch protective cover Depress one switch and release it switch is now up Turn the key switch key in one direction If the curtain does not...

Page 16: ...pon the usage of the unit it is recommended that at least an annual inspection be made at which time the following steps should be taken 1 GENERAL Make certain the Porter key switch is not substituted...

Page 17: ...event damage to the curtain fabric 8 CURTAIN FABRIC Inspect the curtain for tears or holes in the fabric Additional fabric can be supplied for patching purposes Industrial vinyl cement can be used to...

Page 18: ...18 WIRING AT WINCH IMPORTANT NOTE WIRING AT WALL MOUNTED KEY SWITCH IMPORTANT NOTE CAUTION SUBSTITUTION X Y...

Page 19: ...MUM LENGTH 70 0 OR 1600 SQ FT CENTER ROLL GYMNASIUM DIVIDER CURTAIN MAXIMUM 70 0 LENGTH OR 1600 SQ FT CENTER ROLL GYMNASIUM DIVIDER CURTAIN SEE SHEET C 2081 1 FOR INSTALLATION OPTIONS 92081 ___ WALL G...

Page 20: ...ORQUE ARM OPERATED SEE SHEET C 2082 1 FOR INSTALLATION OPTIONS CENTER ROLL GYMNASIUM DIVIDER CURTAIN MAXIMUM LENGTH 70 0 OR 1600 SQ FT CENTER ROLL GYMNASIUM DIVIDER CURTAIN C 2082 MAXIMUM 70 0 LENGTH...

Page 21: ...21 INSTALLER NOTES...

Page 22: ...22 INSTALLER NOTES...

Page 23: ...23 INSTALLER NOTES...

Page 24: ...LER NOTES Porter Athletic Equipment Company 2500 South 25th Avenue Broadview IL U S A 60155 Toll Free 800 947 6783 Phone 708 338 2000 Fax 708 338 2060 www porter ath com SAVE THESE INSTRUCTIONS FOR FU...

Reviews: